Search NASA⌕ Search

Engineering topics

Phillips, Mark C.

Publications and source records attributed to Phillips, Mark C..

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.↗

Evolution and persistence of SiO emission in nanosecond laser ablation plumes

Analyzing laser-produced plasmas in a controlled oxygen-containing environment provides insight into the formation and evolution of molecular species through gas-phase oxidation. This study explores the role of ambient pressure and oxygen availability in forming SiO molecular species in laser ablation plumes. The self-emission emanating during the reactive ablation of Si targets was characterized by optical emission spectroscopy and optical time-of-flight techniques. Our results showed that the SiO species formation was greatly influenced by both the ambient pressure and oxygen availability. The intensity and the persistence of SiO emission bands are lower at higher oxygen concentrations, indicating they are depopulated by the formation of more complex silicon oxides. The oxygen partial pressure effects on plume chemistry showed that SiO formation is favored even with a minimal oxygen concentration in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual-comb spectroscopy in the deep ultraviolet

This Letter reports dual-frequency-comb spectroscopy in the deep ultraviolet used to characterize transient laser-produced plasmas. Dual-comb spectroscopy at these wavelengths enables access to a large number of strong electronic transitions in neutral and ionized atoms and molecules. This broadband dual-frequency-comb system at 265 nm measures multiple transitions in neutral and singly ionized iron atoms in a laser-produced plasma. Analysis of absorption spectra yields time-resolved ion and neutral column densities, excitation temperatures, and electron densities, which are measured down to 10 14 cm —3 levels. The results provide insights into low-temperature plasma properties.

47 OTHER INSTRUMENTATION↗

Comparison of excitation temperature of a laser-produced plasma by combining emission and absorption spectroscopy

Measurement of the temporal evolution of laser-produced plasma temperature is very important for many of its applications, and several plasma diagnostic tools are routinely used by researchers. However, it is very challenging to measure the properties of the plasma at the early and late times of its evolution using a single diagnostic tool. In this study, we combined emission and laser absorption spectroscopy to compare the excitation temperatures of a laser-produced uranium plasma system. Several U I transitions in the near-infrared spectral range (775–800 nm) were considered, and the Boltzmann plot method was used to measure the excitation temperatures using both emission and absorption spectroscopy. Emission spectroscopy provided early-time temperature measurements of the plasma up to times 2–20 µs, while absorption spectroscopy provided temperature measurements at late times of plasma evolution (for times 5–80 µs). The emission and absorbance of U I transitions were found to follow the Boltzmann distribution, indicating the plasma is likely in the state of local thermodynamic equilibrium even at late times of its lifetime. The emission and absorption-based time-resolved excitation temperatures demonstrated good agreement at earlier times (≤15 µs) in the overlapped temporal region, while a deviation in the measured values was seen at times (≥15 µs), and potential reasons for such a disagreement are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of environmental oxygen on nanoparticle formation and agglomeration in aluminum laser ablation plumes

Here, the role of ambient oxygen gas (O 2 ) on molecular and nanoparticle formation and agglomeration was studied in laser ablation plumes. As a lab-scale surrogate to a high explosion detonation event, nanosecond laser ablation of an aluminum alloy (AA6061) target was performed in atmospheric pressure conditions. Optical emission spectroscopy and two mass spectrometry techniques were used to monitor the early to late stages of plasma generation to track the evolution of atoms, molecules, clusters, nanoparticles, and agglomerates. The experiments were performed under atmospheric pressure air, atmospheric pressure nitrogen, and 20% and 5% O 2 (balance N 2 ), the latter specifically with in situ mass spectrometry. Electron microscopy was performed ex situ to identify crystal structure and elemental distributions in individual nanoparticles. We find that the presence of ≈20% O 2 leads to strong AlO emission, whereas in a flowing N 2 environment (with trace O 2 ), AlN and strong, unreacted Al emissions are present. In situ mass spectrometry reveals that as O 2 availability increases, Al oxide cluster size increases. Nanoparticle agglomerates formed in air are found to be larger than those formed under N 2 gas. High-resolution transmission electron microscopy demonstrates that Al 2 O 3 and AlN nanoparticle agglomerates are formed in both environments; indicating that the presence of trace O 2 can lead to Al 2 O 3 nanoparticle formation. The present results highlight that the availability of O 2 in the ambient gas significantly impacts spectral signatures, cluster size, and nanoparticle agglomeration behavior. These results are relevant to understanding debris formation in an explosion event, and interpreting data from forensic investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing the kinetics of ionized and neutral atoms from single and multi-element laser-produced plasmas

In this work, kinetics of ion and neutral atom emission features were compared for nanosecond laser-produced plasmas generated from several metal targets (i.e., Al, Ti, Zr, Nb, Ta) and an alloy containing all of these as principal alloying elements. Plasmas were produced by focusing 6 ns, 1064 nm pulses from an Nd:YAG laser on the targets of interest in a vacuum. A Faraday cup was used for collecting ion temporal features while spatially and temporally resolved emission spectroscopy was used for measuring the optical time of flight of various neutral atomic transitions. Our results highlight that most probable ion and atom velocities decay with increasing atomic mass. Trends for ions from the alloy target represent a weighted average where all ions contribute. For both ions and atoms, velocities decrease with increasing heat of vaporization and melting temperature, consistent with the thermal mechanisms that contribute to nanosecond laser ablation. Kinetic energies for neutral atoms from pure metal targets have some variability with atomic mass, whereas kinetic energies for atoms from the alloy target are more similar. These more similar kinetic energies observed for neutral atoms in the multi-element plasma may be attributed to collisions between species from all elements in the Knudsen layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of excitation and kinetic temperatures in a laser-produced plasma using absorption spectroscopy

High-resolution tunable laser absorption spectroscopy is used to measure time-resolved absorption spectra for six neutral uranium transitions in a laser-produced plasma. Here analysis of the spectra shows that kinetic temperatures are similar for all six transitions, but excitation temperatures are higher than kinetic temperatures from 10–100 μs, indicating departures from local thermodynamic equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tantalum oxide and nitride spectral features from a laser-produced plasma

Here, we report measurements of time-resolved Ta, TaO and TaN emission spectroscopic signatures from a laser-produced plasma. Plasmas were generated using 1064 nm, 6 ns pulses from an Nd:YAG laser focused onto a pure Ta metal target in a gaseous environment with varying percentages of O 2 /N 2 for controlling gas-phase oxidation/plasma chemistry. Time-resolved analysis showed that Ta oxide emission is prominent at later times in plasma evolution, whereas strong atomic emission is present at early times in air. Emission spectral features as a function of O 2 partial pressure showed that TaO emission intensity increases, while the peak intensity of TaO appears earlier with increasing O 2 availability. We also report emission spectra of TaN, and show that plasma chemistry favors TaO formation instead of TaN when O 2 is present in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas-phase oxidation and nanoparticle formation in multi-element laser ablation plumes

The evolution from gas-phase oxidation to nanoparticle and agglomerate formation was studied in nanosecond laser-produced plasmas of a multi-principal element alloy target in air. Here gas-phase oxidation of plasma species was monitored in situ via optical emission spectroscopy, while a custom-built single particle mass spectrometer was used to measure size and compositions of agglomerated nanoparticles formed in laser ablation plumes. Ex situ analysis employing transmission electron microscopy was used to study nanoparticle morphology, crystal structure, and element distribution at the nanoscale. Emission spectra indicate that gas-phase oxidation of elements in the alloy target are formed at varying times during plume evolution, and mass spectrometry results indicate fractal agglomerates contain all principal alloying elements and their oxides. Finally, electron microscopy characterization illustrates that these agglomerates consist of multiple material types: sub-10 nm diameter amorphous, multi-element nanoparticles, ≈10–30 nm diameter Ti-rich crystalline oxide nanoparticles, and ejected base material. Results highlight that the multi-component target composition impacts molecular formation in the gas phase and the morphology, composition, and structure of nanoparticles and agglomerates formed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical spectroscopic tools for standoff uranium detection

Rapid and standoff analysis of uranium is important for many applications. We present the recent advances in standoff detection of uranium using emission and laser-induced fluorescence spectroscopy in conjunction with ultrafast laser filament ablation-based solid sampling.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Standoff Infrared Measurements of Chemical Plume Dynamics in Complex Terrain Using a Combination of Active Swept-ECQCL Laser Spectroscopy with Passive Hyperspectral Imaging

Chemical plume detection and modeling in complex terrain present numerous challenges. We present experimental results from outdoor releases of two chemical tracers (sulfur hexafluoride and Freon-152a) from different locations in mountainous terrain. Chemical plumes were detected using two standoff instruments collocated at a distance of 1.5 km from the plume releases. A passive long-wave infrared hyperspectral imaging system was used to show time- and space-resolved plume transport in regions near the source. An active infrared swept-wavelength external cavity quantum cascade laser system was used in a standoff configuration to measure quantitative chemical column densities with high time resolution and high sensitivity along a single measurement path. Both instruments provided chemical-specific detection of the plumes and provided complementary information over different temporal and spatial scales. The results show highly variable plume propagation dynamics near the release points, strongly dependent on the local topography and winds. Effects of plume stagnation, plume splitting, and plume mixing were all observed and are explained based on local topographic and wind conditions. Measured plume column densities at distances ~100 m from the release point show temporal fluctuations over ~1 s time scales and spatial variations over ~1 m length scales. The results highlight the need for high-speed and spatially resolved measurement techniques to provide validation data at the relevant spatial and temporal scales required for high-fidelity terrain-aware microscale plume propagation models.

47 OTHER INSTRUMENTATION↗

Multi-species temperature and number density analysis of a laser-produced plasma using dual-comb spectroscopy

Dual-comb spectroscopy (DCS) represents a novel method of using absorption spectroscopy as a diagnostic tool for multispecies analysis of excitation temperatures and column densities in laser-produced plasmas (LPPs). DCS was performed on a LPP generated by ablating a multielement alloy containing Nd, Gd, and Fe. Transitions from all three elements were observed in absorption spectra measured from 530.08 to 535.19 nm at seven time-delays from 31 to 250 μs after ablation. The spectra were fit using a nonlinear regression algorithm to determine peak areas, and excitation temperatures and column densities were determined for the three atomic species separately using Boltzmann plots. The measured excitation temperatures of Nd I and Gd I showed good agreement at all time-delays, whereas the Fe I temperature was found to be higher, and the ratios between the column densities varied with delay. The observations are understood via effects of LPP spatial averaging, elemental fractionation, and molecular formation and are compared and contextualized with previous work studying LPPs using other spectroscopic techniques. A brief discussion of the precision and accuracy of the determined excitation temperatures and column densities is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗