Search NASA⌕ Search

Engineering topics

Phillips, Tyler Bennett

Publications and source records attributed to Phillips, Tyler Bennett.

Techno-economic assessment of electricity market potential for co-located hydro-floating PV systems

Abstract—Harnessing renewable energy from diverse sources is paramount for sustainable power systems. Recently, co-located floating PV (FPV) systems present an intriguing prospect in this context. These hybrid systems, blending hydro and solar power, may offer a more consistent electricity output and potential economic advantages. Yet, assessing their actual potential requires a comprehensive techno-economic assessment. In addition, probabilistic price forecasting has recently gained attention in electricity market because decisions based on such predictions can yield significantly higher profits than those made with point forecasts alone. To this end, this paper embarks on a journey to elucidate the electricity market potential of co-located hydro-FPV systems in a probabilistic fashion to investigate the technological merits and economic viability of co-located hydro-FPV under different market structures. Our preliminary findings suggest that LCOE and payback metrics are sensitive not only to different markets but also to different solar incentives. Concurrently, we also observe that the payback period is generally faster with a production tax credit (PTC) than an investment tax credit (ITC). This assessment serves as a cornerstone for understanding the future prospects of co-located hydro-FPV systems in modern electricity markets.

13 HYDRO ENERGY↗

Impact of Floating PV (FPV) System on Water Evaporation: Case Study of an Open Loop Reservoir in North Carolina

Fresh water scarcity is becoming one of the important concerns worldwide. This situation of water scarcity is further exacerbated by the increase in water evaporation due to climate change. This manuscript will address this concern by considering the impact of floating photovoltaics (FPVs) systems on water evaporation. The installation of PV modules on the water bodies can help reduce the water evaporation rate from reservoirs by reducing the evaporating area of the water surface. This work evaluates the effect of FPV on water evaporation rates in the TuckerTown reservoir located in North Carolina state of United States. Meteorological data, such as mean temperature and dew-point, are used to calculate the rate of the water evaporation by Linacre method. The simulation results for the TuckerTown case study showed that the aggregated avoided evaporated volume for one year is 9 million gallons.

14 SOLAR ENERGY↗

2023 FORCE Development Status Update

Technical and economic analysis of integrated energy systems (IES) using software models is a complex process requiring multiple commodity market decision analysis, optimal control, process modeling, and stochastic analysis. Many assumptions used in traditional energy analysis tools do not hold in future energy markets with significant storage and variable renewable energy sources (VRE), let alone with multiple commodity markets. Capturing these intricate elements for accurate techno-economic analysis of IES led to the development of the Framework for Optimization of ResourCes and Economics (FORCE) tool suite under the U.S. Department of Energy’s Integrated Energy Systems crosscutting technology program. With the aim of a full framework release in 2025, many improvements to the FORCE tool suite were developed in fiscal year 2023 (FY23). These improvements broadly fit into three focuses for development of FORCE: capability, accessibility, and reliability. Capability refers to the ability of FORCE to accurately model the technical and economic viability of various IES. Accessibility refers to ease-of-use for new and existing IES analysts to efficiently set up, analyze, and produce results using FORCE. Reliability refers to the consistency of the software, allowing consistency to analysis regardless of erstwhile changes to the software. In addition to many smaller changes, there are three major capability improvements in FORCE in FY23. In summary, FORCE developments in FY23 have moved us close to all the capability requirements for FORCE 1.0 to be delivered in FY25. Inclusion of Bayesian optimization, resilience metrics, and levelized cost analysis expand the capability, accessibility, and reliability of FORCE.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Operational Resilience Metric to Evaluate Inertia and Inverter-based Generation on the Grid

In an effort to reduce carbon emissions and curtail the effects of climate change there has been considerable effort to increase the penetration of inverter-based renewable energy sources. The adoption of renewable generation over conventional inertia-based generation sources is forming considerable challenges for the operation and stability of the power system. The power system has been designed around generation units characterized by high inertia and primary frequency response (PFR), allowing them to respond to disturbances such as faults or generators tripping off line. In contrast, the modern inverter-based assets are characterized by no contribution to inertia and they typically provide stochastic generation at their maximum output, thus having no contribution to PFR during low-frequency disturbance events. Because of this, inertia in power systems is reducing, resulting in a faster rate of frequency change after a disturbance occurs. As more inverter-based generation units are added to the grid it is important to understand the stability of the system and the size of disturbance a system is capable of withstanding. This paper presents a resilience metric that evaluates the maximum size of disturbance a systems can withstand based on the system inertia and the primary frequency control of inverter and inertia-based generation. The results are shown visually and are based on the real-time operation of generation units and their characteristics such as latency, ramp rates, and energy constraints. It is demonstrated that the real-time positioning or bias of the generating units has an effect of the size of disturbance that a system can withstand, i.e. its resilience. It is expected that this type of analysis can help operators increase the resilience of power systems in the future.

13 HYDRO ENERGY↗

Forecasting Dynamic Line Rating with Spatial Variation Considerations

Dynamic line rating (DLR) is a technology that allows the ampacity of an electrical conductor to be calculated using real-time or forecasted weather conditions. Historically, the ampacity of a conductor has been determined using a static line rating method which assumes conservative weather assumptions. Therefore, not only can DLR give a more accurate measurement of the true ampacity of a conductor, but it can also increase its ampacity during weather conditions with greater thermal mitigations. The two primary cooling factors in the ampacity calculations are wind speed and direction. In complex terrain, wind speed and direction can have large variations over short distances. Therefore, accurately identifying the limiting span of a transmission line requires high spatial resolution of the wind along its path. One solution is to install dense weather stations along their path, though this can become costly over long distances. Therefore, researchers have investigated the use of Computation Fluid Dynamic (CFD) simulations to accurately compute the wind field along the path of a transmission line and use these results to identify the limiting section of the conductor. This work presents a case study that evaluates the coupling of CFD simulations and forecasted weather simulations using the High-Resolution Rapid Refresh (HRRR) model points over a 2-year span within a region in south eastern Idaho. The primary goal of the work is the evaluation of the number of HRRR model points used, i.e., weather stations, along the path of the line and the accuracy of the resulting DLR ampacity. This was done using 4, 10, 17, 26, and 35 HRRR model points along two transmission line paths. The results indicate that as the number of model points are increased, the DLR ampacity of the lines decrease, yet converge as more points are added and demonstrate little change with additional HRRR points. It is expected that these results can help transmission line operators identify the number of weather stations that must be installed when coupled with CFD simulations and DLR ampacity to ensure accurate ratings and safe operations.

17 WIND ENERGY↗

Forecasting Dynamic Line Rating with Spatial Variation Considerations

Dynamic line rating (DLR) is a technology that allows the ampacity of an electrical conductor to be calculated using real-time or forecasted weather conditions. Historically, the ampacity of a conductor has been determined using a static line rating method which assumes conservative weather assumptions. Therefore, not only can DLR give a more accurate measurement of the true ampacity of a conductor, but it can also increase its ampacity during weather conditions with greater thermal mitigations. The two primary cooling factors in the ampacity calculations are wind speed and direction. In complex terrain, wind speed and direction can have large variations over short distances. Therefore, accurately identifying the limiting span of a transmission line requires high spatial resolution of the wind along its path. One solution is to install dense weather stations along their path, though this can become costly over long distances. Therefore, researchers have investigated the use of Computation Fluid Dynamic (CFD) simulations to accurately compute the wind field along the path of a transmission line and use these results to identify the limiting section of the conductor. This work presents a case study that evaluates the coupling of CFD simulations and forecasted weather simulations using the High-Resolution Rapid Refresh (HRRR) model points over a 2-year span within a region in south eastern Idaho. The primary goal of the work is the evaluation of the number of HRRR model points used, i.e., weather stations, along the path of the line and the accuracy of the resulting ampacity. This was done using 4, 10, 17, 26, and 35 HRRR model points along two transmission line paths. The results indicate that as the number of model points are increased, the DLR ampacity of the lines decrease, yet converge as more points are added and demonstrate little change with additional HRRR points. It is expected that these results can help transmission line operators identify the number of weather stations that must be installed when coupled with CFD simulations and DLR ampacity to ensure accurate ratings and safe operations.

17 WIND ENERGY↗

An Operational Resilience Metric for Modern Power Distribution Systems

The electrical power system is the backbone of our nations critical infrastructure. It has been designed to withstand single component failures based on a set of reliability metrics which have proven acceptable during normal operating conditions. However, in recent years there has been an increasing frequency of extreme weather events. Many have resulted in widespread long-term power outages, proving reliability metrics alone do not provide adequate energy security. As a result, researchers have focused their efforts on a new set of metrics based on the concept of resilience to ensure efficient operation of power systems during extreme events. A resilient system has the ability to resist, adapt, and recover from disruptions. Therefore, resilience has demonstrated itself as a promising concept for currently faced challenges in power distribution systems. In this work, we propose a real-time resilience metric for modern power distribution systems. The metric is an aggregation of the controllable assets adaptive capacity, or their temporal flexibility in real and reactive power. This metric gives information to the magnitude and duration of a disturbance which the system can respond to without having to drop loads or have stability issues in voltage or frequency. We demonstrate the impact to resilience in a case study under normal operation and during a power contingency on a microgrid. In the future, this information can be used by operators to make more informed decisions based on system resilience in an effort to prevent power outages.

42 ENGINEERING↗

A metric framework for evaluating the resilience contribution of hydropower to the grid

This paper will describe a proposed framework for expressing the resilience of hydropower generation and provide initial case studies for three classes of hydropower, run-of-river hydropower, hydropower with reservoirs, and pumped storage hydropower. Hydropower has great flexibility to provide support during and after natural and man-made events that can disrupt critical infrastructure functionality. The concept of the framework provides for consideration of policy and rules, constraints of the water shed and other allocations of water, storage and plant capabilities to produce real and reactive power, and the strength of the delivery network. The paper details a resilience response metric that has inputs of state of storage and plant level constraints on real and reactive power production. Using the definition of resilience, based on maintaining a minimally normal operations, we provide a qualitative assessment of hydropower’s ability to address the various time scales comprising the “R”s of resilience.

13 HYDRO ENERGY↗

A Framework for Evaluating the Resilience Contribution of Solar PV and Battery Storage on the Grid

Motivated by decreased cost and climate change concerns, penetration of solar photovoltaic (PV) and battery energy storage has been continually increasing. The variability in solar generation assets has led to many challenges for utilities and researchers. Therefore, there is increasing interest in the area of resilience of the grid and contribution from its assets. This paper describes a proposed framework for evaluating the resilience contribution of solar generation and battery storage. The metric provides a quantifiable adaptive capacity measure with uncertainty for the contribution assets proved to the bulk grid. A case study using long and short-term solar generation, with and without battery storage, demonstrates the framework and provides useful insight to the resilience solar and battery storage assets contribute.

14 SOLAR ENERGY↗