Verification of Adaptive Protection in Hardware in the Loop for Coordination with Solar Variability

As inverter-based resources continue to be installed at all levels of the electric grid, the fixed protection schemes used at the distribution level will continue to be stressed until they no longer ensure the protection of the grid. Adaptive protection has been proposed as a solution with the ability to update the protection schemes in near real-time to ensure reliability and increase the resilience of the grid. However, weather variability poses a significant challenge to the ability of these methods to keep the selectivity and reliability of these schemes coordinated. If the ramp rates, due to solar variability, of the inverter-based resources change faster than the adaptive protection can issue new settings, the protection system could be uncoordinated, with the wrong device responding to a system fault. The proposed adaptive protection method ensures that due to solar variability, communication, and protection calculation latency, it can issu e coordinated protection settings promptly, in one minute or less. The hardware-in-the-loop results show the protection settings being issued and maintaining system coordination in under a minute.

Summers, Adam↗

Inertia Estimation Under High Penetration of Inverter-based Resources

Many types of renewable energy sources, especially solar and wind generation, are connected to the electric grid through power-electronic-based interfaces (inverters). These inverter-based resources (IBRs) are mechanically decoupled from the grid, which reduces system inertia and thus may compromise its stability and reliability. In this study, we examine the impact of high penetration of IBRs on the power grid’s inertia. To achieve this, we intentionally introduce disturbances into a simulation case study, such as a step load change, to observe and record the system’s frequency responses. This study offers a nuanced understanding of how the integration of IBRs affects grid stability, and it provides essential guidance for future grid management and resilience strategies.

Yadav, Ajay↗

Technical Learning and Integration of Interns in Advanced Protection Lab Space: Enhancements to Testbed and Experiments to Improve Workflows for Producing Datasets

This report presents a successful technical learning integration of student interns in the Advanced Protection Laboratory space, located in the Grid Research Integration and Deployment Center (GRID-C) at the Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL). The Advanced Protection Laboratory was created for the primary goal of supporting DOE’s research projects and technical staff at ORNL. As a secondary goal, the space was used for collaborating with ORNL’s intern programs, providing support to the lab’s mentors and student interns. In 2024, three student interns spent a summer in the Advanced Protection lab space and were involved in the DarkNet Distributed Ledger Technology (DLT) project. The students had a great opportunity to gain hands-on experience with communication and protective relay equipment focused on information technology, data analytics, and cybersecurity. Experiences in the lab space with real equipment and software integration offer education and professional development for students, which is especially important because of a need in the energy industry to recruit highly skilled power and communication engineers.

42 ENGINEERING↗

Advanced Measurements for Resilient Integration of Inverter-Based Resources: PROGRESS MATRIX Final Report

As nearly every aspect of the electric power grid undergoes rapid change, measurement technologies that support grid operation and planning must evolve as well. The rapid large-scale deployment of inverter-based resources (IBRs) vital to achieving the nation’s clean energy goals has in some cases led to negative impacts on the reliability and security of the bulk power system (BPS). Advanced power system measurements, including synchronized phasor and waveform measurements, are key to making IBR integration secure and reliable. To this end, the Department of Energy (DOE) initiated the PROGRESS MATRIX project to develop advanced measurement capabilities and analytics that will accelerate adoption of IBRs while improving the reliability and resilience of the BPS. This report discusses the outcomes of the project, which was a joint effort between the Pacific Northwest National Laboratory (PNNL), Oak Ridge National Laboratory (ORNL), the National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL). In the project’s first year, PNNL, NREL, and ORNL partnered with the Bonneville Power Administration (BPA), the Western Area Power Administration (WAPA), and Kauai Island Utility Cooperative (KIUC) to understand their existing measurement capabilities and the gaps limiting deployment of IBR-focused measurement systems and analytics. The other primary activity in the first year was deployment of GridSweep instruments, which provide unprecedented precision in waveform measurement while probing distribution systems. The instruments were deployed at Dominion Energy and the University of California, Riverside. In the project’s second year, the input from partner utilities and collected measurements were used to advance measurement capabilities. Twelve analytical methods spanning disturbance analysis, power plant evaluation, feeder evaluation, and modeling were developed. Two software tools were developed, one to analyze GridSweep measurements and another to automatically evaluate the control performance of power plants connected to the BPS. Testbeds at ORNL and NREL were augmented to better enable studies of IBR integration. The project culminated in demonstrations of these analytical methods, software tools, and testbeds, both in the field and in the laboratory. This report discusses these various accomplishments and documents the significant progress in developing advanced measurement capabilities to support the secure, reliable, and accelerated adoption of IBRs in the BPS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical Fault and Power Quality Detection Algorithms and Customer-Owned DERs Monitoring with a Cyber Grid Guard System and DLT

In this study, the electrical fault and power quality detection algorithms and customer-owned DERs monitoring use cases were implemented, with a Cyber Grid Guard system and DLT. Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substations, and are associated with customer-owned distributed energy resources (DERs). Data from these IEDs, such as power meters and protection relays, must be kept confidential and of high integrity. Blockchain technology has the potential to increase microgrid resilience by enhancing data sharing security. The growing use of IEDs and customer-owned renewable energy sources (DERs) may make it necessary to connect Distributed Ledger Technology (DLT) with power system applications. We implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in the loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results showed the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, power system applications for the ESGT with DERs and the CGG system will be based on executing smart contracts between electrical utilities and customer-owned DERs.

Piesciorovsky, Emilio↗

Cyber Resilience in the Cast Timing System

Our task within the DarkNet project was to test the cyber resiliency of the Center for Alternate Synchronization and Timing’s (CAST) framework. We focused our testing on two of the core pieces of CAST’s implementation, a Juniper MX204 router and the Precision Time Protocol (PTP). In this report, we cover the following attempted methods of attack on our targets: ping flood, fork bomb, network protocol fuzzing, ARP poisoning, and IGMP spoofing. We found that delaying certain packets, specifically Delay Request, had a significant impact on the Offset from Master and Observed Drift timing statistics.

97 MATHEMATICS AND COMPUTING↗

EmSense: A High-Resolution Emulated Sensor for Experiments with the Smart Grid and Distributed Ledger Technology

This work involves the development of a device - EmSense (“Emulated Sensor”) - that emulates a high-resolution sensor for a power grid. The device collects raw current and voltage sensor data which derive from ORNL's signature library. This library is a dataset that ORNL curates from many different sources that include power systems from various utilities. The EmSense packages the data from the library in the form of IEC 61850 Sampled Value (SV) packets and then broadcasts these SV packets on the network. In another mode, EmSense can generate artificial sinusoidal data that appears as waveforms for voltage and current signals. EmSense has an internal algorithm for determining the period of a signal based on the data so that the period can be specified as a variable in the IEC 61850 packets. The purpose of EmSense is to allow for experimentation with the Dark Net Infrastructure where a variety of power line sensors must be represented along with their typical communication traffic. The EmSense device was developed in coordination with the software for receiving and processing the packets in the Distributed Ledger Technology (DLT) framework of the DarkNet Project. This receiving software must have a methodology for dealing with information of high velocity, variety, and volume. Experimenting with EmSense facilitates the development of such software. The results showed that the DLT framework and the trust-anchoring approach managed to process a large flow of traffic even with up to six instances of EmSense device broadcasting data. This was achieved without overfilling packet queues in the memory of the actual hardware of the DLT devices or causing the Central Processing Unit (CPU) of the hardware to be overwhelmed. The DLTs were also able to store the data in a compact and useful form for later analysis and archival purposes.

Werth, Aaron↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase to phase ground and phase to ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase to ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and non-faulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/ Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

Piesciorovsky, Emilio↗

Supply Chain Management in Cyber Grid Guard Framework

Grid modernization has impeded innovative power grid applications and energy resources that are increasingly distributed. Blockchain/distributed ledger technology (DLT) has the potential to enhance the resilience of the electric infrastructure, particularly in a decentralized and distributed environment. The benefits of blockchain are to ensure asset information and lifecycle events are secure and traceable and identify potential malicious modification of data. Oak Ridge National Laboratory (ORNL) has developed a framework, Cyber Grid Guard (CGG), incorporating blockchain. The system implements a low-energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems, including substations, control centers, and metering infrastructures. Currently, one of the major concerns is supply chain attacks. There have been several recent attacks that have significantly impacted critical infrastructures and organizations around the world. This document focuses on how CGG can be used to address the supply chain issue.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

Clean Energy Technology Applications on US Mine Land: Technical Analysis

As the United States transitions toward a clean energy economy, an opportunity exists for redeveloping the more than 17,000 mine land sites located across the nation with clean energy technologies, which have a combined potential for generating more than 85 GW of clean electricity. This report provides an overview of the potential of demonstrating and deploying clean energy projects on current and former mine land. Clean energy project refers to a project that demonstrates one or more of the following technologies: solar; microgrids; geothermal; direct air capture; fossil-fueled electricity generation with carbon capture, utilization, and sequestration; energy storage, including pumped storage hydropower and compressed air energy storage; and advanced nuclear technologies. The report discusses the following technologies and their potential for creating jobs and generating tax revenue that would result in direct and indirect benefits to the local economy: Solar photovoltaics (PV) is being developed on current and former mine land in various parts of the world, including the United States. This approach is attractive because it requires limited infrastructure investment and would utilize the bare surfaces of mines and tailing ponds. Solar resource availability may be greater in the southern regions, including the Interior and Appalachian Basins and the southwestern United States. However, since some mine land sites include areas of significant change in elevation, the deployment of PV on mine land may require sophisticated planning to account for shading and irradiance, or may require regrading of the areas. PV does not create significant environmental risks and generally does not face public resistance; Geothermal systems are often spatially and genetically associated with ore deposits, and in some cases, they have been discovered while in search for epithermal mineral resources. Numerous diverse geothermal applications have been employed at mine land around the world, including power generation, mineral extraction from geothermal brines, process heating, direct use for other mining operations, and direct use for non-mining operations and subsurface energy storage, including geothermal heat pumps. Case studies highlighting these applications provide key lessons relating to identifying drivers and barriers to geothermal resource deployment and can be used to create screening tools for identifying the types and locations of mine land most amenable to utilizing geothermal resources; Carbon capture, utilization, and sequestration technologies include direct air capture (DAC) and enhanced weathering. DAC technologies include air contactors, regeneration systems, and CO 2 compression systems. Captured CO 2 can be converted to valuable feedstocks or possibly injected into abandoned subsurface mines where it would be absorbed by alkaline rock waste and mine tailings or by the porous minerals along the walls of the mine. DAC systems can be coupled with energy sources such as wind, solar, grid, or geothermal. Many DAC systems require a source of water or steam; however, some are expected to be net producers of water. Local impacts of DAC systems are expected to be low, and are related to land footprint, material disposal, and upstream impacts of energy and material production; Compressed air energy storage is an established energy storage technology in salt caverns. It has the potential for implementation in underground mines by pressurizing and storing a large amount of air using electrical compressors when excess electricity is available. When a need for discharge emerges, the air is used to spin turbines and produce the necessary volume of electricity. Abandoned or unused mine openings, including shafts, adits, access tunnels, and mined workings of any orientation, offer potential for vast amounts of compressed air energy storage if the site characteristics meet operational requirements; Pumped hydropower storage can be implemented in surface and subsurface mines. In surface mine applications, both reservoirs may be located in a mine pit or artificial reservoirs made of excavated materials. In subsurface mines, the lower reservoir may be implemented by waterproofing and flooding mine shafts and tunnels. The water is then pumped from the lower reservoir to the upper reservoir during periods of low load and high production, and it is discharged through the turbines during periods of peak demand. The potential environmental damages associated with acidity of mine water or the presence of toxic chemicals incentivizes the development of closed-loop technologies, in which water circulates inside the pumped hydropower facility without being discharged into the external water basins; Advanced nuclear energy technologies include small modular reactors, which can be deployed locally to produce electricity and heat. Such units require seismic stability and a supply of cooling water, but population constraints may exist in some areas. Therefore, remote mine land could represent an optimal location for siting advanced nuclear energy technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Model-Adaptive Relaying Applied to Microgrid Protection

In microgrids, the short-circuit current magnitude is significantly limited by more than an order of magnitude due to the relatively small inverter-based resources. Commercially available protective devices for distribution cannot reliably protect a microgrid due to their dependence on the magnitude of the fault current. Moreover, overcurrent relays typically cannot function properly for a microgrid because they are incapable of detecting faults and/or performing the coordination between the relays in inverter-based microgrids operated in the islanded mode. This paper proposes a model-adaptive relay designed to adjust the relay curves based on the available generation and the network topology. The proposed method runs a real-time model of the microgrid, which gathers information from the network to calculate the available short-circuit current in the specified node. The fault current from the model is then used for the adaptive algorithm to calculate the relay settings, considering coordination with the downstream fuses and upstream reclosers. This work presents the validation of the proposed method in Hardware-in-the-Loop, in a hardware testbed as well as field deployed in a real microgrid in East-Tennessee.

24 POWER TRANSMISSION AND DISTRIBUTION↗