Search NASA⌕ Search

Engineering topics

Pishahang, Mehdi

Publications and source records attributed to Pishahang, Mehdi.

Metal-to-Ceramic Joining Methods to Support Development of Advanced Ceramic-Based CSP Components

The National Renewable Energy Laboratory, Missouri University of Science and Technology (MS&T), Massachusetts Institute of Technology (MIT), and Colorado School of Mines (CSM) collaborated to design, develop, and test a material concept at bench scale which will be used to achieve a ceramic-to-metal (C2M) joint between a selected metal HTF loop material and a selected ceramic material used by the Gen3 CSP technology pathway. The final joint assembly will need to possess sufficient mechanical properties to withstand static high-temperature (650 degrees-700 degrees C) and high-pressure (20 MPa) and thermal cycling (between 650 degrees C and 100 degrees C) conditions. The material concept consists of three key components: (1) a ceramic matrix composite (CMC) that serves as a compliant transition material aiming to mitigate the stresses due to the mismatch of coefficient of thermal expansion (CTE) from a direct ceramic-to-metal joint, (2) a metal-end joint utilizing a multi-principal element alloy (MPEA) with changing percentage of particle loading to bond the candidate metal to the CMC, and (3) a ceramic-end joint utilizing a glass ceramic to bond the candidate ceramic to the CMC.

14 SOLAR ENERGY↗

The importance of maldistribution matching for thermal performance of compact heat exchangers

Compact heat exchangers have gained increased attention in recent years, particularly in demanding applications where high temperatures, high pressures, and/or high power densities are required. For decades, the heat exchanger (HX) community believes that flow maldistribution is a key factor for HX effectiveness, that is, reducing the degree of flow maldistribution (MALD) can help increase the HX effectiveness. Therefore, significant efforts have been devoted in the past to optimizing the header geometry to minimize flow maldistribution. This work was initially motivated by this, and the original goal was to figure out a HX header design with the lowest maldistribution. However, by systematically constructing a comprehensive maldistribution matrix, the analysis revealed that the HX effectiveness is not actually determined by the MALD, but instead dominated by the degree of maldistribution mismatch (MISM). This conclusion was also theoretically generalized, which indicated that matching of the local heat capacity rate is key for achieving maximum performance. The MISM provides a local means of tracking this information, while the MALD only provides a global approximation of the maldistribution itself. With this new perspective, flow maldistribution needs not necessarily be avoided, but instead matched between two fluid streams, to improve the HX performance. We demonstrated that by carefully designing the header geometry to match the velocity profiles of the two fluids in a 2 MW PCHE with molten salt and supercritical carbon dioxide (sCO2) as the heat transfer fluids, the HX could achieve a higher effectiveness even when the maldistribution increased. Finally, a technoeconomic study using a CSP system as an example revealed that the use of this new HX design paradigm could result in CSP capital cost savings as large as 16.6%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of the Porous Medium Approximation for Hydrodynamics Analysis in Compact Heat Exchangers

Compact heat exchangers (HXs) have gained attention in recent years in various fields such as solar and nuclear power generation, oil and gas, and refrigeration due to their low cost, high power density, and robustness in high-pressure and/or high-temperature environments. However, the large difference between a compact HX's overall dimensions (~m) and the much smaller scale of its channels (~mm) makes it challenging to model the entire HX at once, due to computational limitations. In this work, we treat the channeled region of a compact HX as a porous medium (PM) to circumvent the need to model/mesh each individual channel. This allows us to simulate the entire HX, including both the header and channeled regions while maintaining the computational cost at a practical level. Although the porous medium approach has been used to model heat exchangers, its validity is still questionable because (1) the resistance coefficients are heavily data-based and thus difficult to be applied to new heat exchangers and (2) the validation has been focused on matching the overall pressure drop in the channel region, which does not address whether such model can predict detailed pressure and velocity field. For the first time, this work addresses under what circumstances and with what uncertainty does the PM approach work for hydrodynamics modeling in compact HXs. By answering these questions, we introduce the PM approach as a powerful tool for HX hydrodynamics modeling that can predict not only the overall pressure drop but also the detailed pressure and velocity distributions.

Engineering↗

Thermal energy grid storage: Liquid containment and pumping above 2000 °C

As the cost of renewable energy falls below fossil fuels, the key barrier to widespread sustainable electricity has become availability on demand. Energy storage can enable dispatchable renewables, but only with drastic cost reductions compared to current battery technologies. One electricity storage concept that could enable these cost reductions stores electricity as sensible heat in an extremely hot liquid (>2000°C) and uses multi-junction photovoltaics (MPV) as a heat engine to convert it back to electricity on demand hours, or days, later. Furthermore, this paper reports the first containment of silicon in a multipart graphite tank above 2000°C, using material grades that are affordable for energy storage at GWh scales. Low cost molded graphite with particle sizes as large as 10 μm successfully contained metallurgical grade silicon, even with as much as twothirds iron by mass for up to 10 hours and temperatures as high as 2300°C, in tanks as large as two gallons.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a 2 MW ZrC/W-based molten-salt-to-sCO 2 PCHE for concentrated solar power

To increase the power cycle efficiency and lower the levelized cost of electricity (LCOE) of concentrated solar power (CSP) plants, printed circuit heat exchangers (PCHEs) capable of operating above 700 °C with molten chloride salt and a sCO 2 -based fluid are needed. In this paper, the design of a high-pressure, high-temperature, 2 MW PCHE comprised of a thermomechanically-robust, zirconium carbide/tungsten (ZrC/W) composite is conducted for CSP plants. The ZrC/W composite is a material with high thermal conductivity, high stiffness, and high failure strength at high temperatures, along with excellent resistance to thermal cycling and thermal shock. In this work, a thermomechanical design analysis was conducted to select appropriate material thicknesses of the ZrC/W plates, and to determine the geometrical dimensions and the thermal performance of the PCHE. The influences of the plate number and heat exchanger length on power density and pressure drop have also been systematically investigated. Economic analyses were conducted to compare the cost of ZrC/W-based PCHEs to those comprised of IN740H (a state-of-the-art, nickel-based superalloy) and 316 stainless steel (316SS). Finally, at a sufficiently high plate production rate, the manufacturing cost of ZrC/W-based PCHEs can be significantly lower, while achieving a much higher power density, compared with state-of-the-art, nickel alloy-based and stainless steel-based PCHEs.

14 SOLAR ENERGY↗

High-temperature Pumping of Silicon for Thermal Energy Grid Storage

As the cost of renewable energy falls below fossil fuels, the key barrier to widespread sustainable electricity has become availability on demand. Energy storage can enable dispatchable renewables, but only with drastic cost reductions compared to current batteries. One electricity storage concept that could enable these cost reductions stores electricity as sensible heat in an extremely hot liquid (>2000 °C) and uses multi-junction photovoltaics (MPV) as a heat engine to convert it back to electricity on demand, hours or days later. This paper follows previously reported technoeconomics and liquid containment, examining equipment that would be needed to exchange heat between resistive heaters, a molten silicon storage tank above 2000 °C, and a heat engine. Herein, we report on a pump that was designed and tested to circulate the liquid silicon between these three regions and the effect of spatial thermal cycling was simulated in models and experiments. While the pump successfully circulated silicon between 1800-2080 °C for ten hours, circulation with a temperature gradient caused it and other non-isothermal experiments to dissolve significantly due to the temperature dependent solubility of not only carbon, but also silicon carbide which otherwise protected the graphite infrastructure. Furthermore, methods to reduce dissolution and an alternative embodiment are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗