Search NASA⌕ Search

Engineering topics

Piva, R.

Publications and source records attributed to Piva, R..

Interaction between an upstream facing wall jet and a supersonic stream

The flow field resulting from the interaction of an upstream facing wall jet with a supersonic counterflowing stream has been investigated. A flow field model and the main parameters governing the phenomena were determined from quantitative and qualitative experimental observations. Experimental results for different ranges of the main parameters are presented. A theoretical analysis was performed to describe the flow field in the mixing region between the two counterflowing streams. The results obtained by applying a locally similar solution compare favorably with the experimentally measured values. Large values of jet penetration were obtained with a high subsonic or low supersonic jet; large interaction forces are characteristics of higher supersonic injections. For the case of large penetration the cooling effectiveness presented as a function of the main parameters indicates the possibility of interacting cooling applications.

Piva, R.↗

Heat transfer distribution on a discontinuously convective cooled surface

An active cooling scheme in which discrete cooling passages are used was investigated. In this scheme, the coolant passages are placed perpendicular to the main stream direction. Streamwise temperature oscillations result from the highly cooled regions, near the coolant channels, being next to regions not directly cooled between the channels. The accuracy of the heat transfer rate predictions by these approximations was evaluated by means of both experimental and numerical investigations. Experiments were conducted at free stream Mach number of 6 with several cooling passages. Heat transfer measurements were made and corresponding theoretical analysis were performed for comparison in evaluating both local and overall deviations in the heat transfer rate.

Piva, R.↗

Leading edge cooling by upstream injection

A leading edge cooling system by upstream along the surface was investigated. The purpose of this system is to keep the leading edge below a desired temperature without excessively increasing the radius of the tip and consequently the total pressure losses. An experimental investigation was conducted to find the optimum conditions for the cooling from the point of view of upstream jet penetration and minimum shock losses. A theoretical analysis was performed to study the flow field in the mixing region between the two counterflowing streams and the results obtained compare favorably with the experimental results.

Piva, R.↗