Search NASA⌕ Search

Engineering topics

Platt, Mark

Publications and source records attributed to Platt, Mark.

A stress-induced source of phonon bursts and quasiparticle poisoning

Abstract The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called “quasiparticle poisoning”. Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reduction in radioactivity-induced backgrounds using a novel active veto detector for rare event search experiments

The results of a newly developed annular cryogenic phonon-mediated active veto detector are discussed which shows a significant reduction of radioactivity-induced backgrounds in rare event search experiments. The veto detector is made up of germanium weighing ∼500 g with an outer diameter of 76 mm and an inner diameter of 28 mm. The detector can host a 25 mm diameter germanium inner target detector of mass ∼10 g. A GEANT4 simulation with the active veto and inner target detector shows a gamma background reduction of 50 - 80% which is further improved (> 90%) with 4pi veto coverage. Experimental measurements with the detector assembly agree well with the simulation.

Chaudhuri, Mouli↗

Removal of 210 Pb by etch of crystalline detector sidewalls

A potential source of dominant backgrounds for many rare-event searches or screening detectors is from radon daughters, specifically 210 Pb, deposited on detector surfaces, often during detector fabrication. Performing a late-stage etch is challenging because it may damage the detector. Here, this paper describes a late-stage etching technique that reduces surface 210 Pb and 210 Po by > 99x at 90% C.L.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single electron–hole pair sensitive silicon detector with surface event discrimination

Here, we demonstrate single electron-hole pair resolution in a single-sided, contact-free 1 cm$^2$ by 1 mm thick Si crystal operated at 48 mK, with a baseline energy resolution of 3 eV. This crystal can be operated at voltages in excess of $\pm50$ V, resulting in a measured charge resolution of 0.06 electron-hole pairs. The high aluminum coverage ($\sim$70%) of this device allows for the discrimination of surface events and separation of events occurring near the center of the detector from those near the edge. We use this discrimination ability to show that dark events seen in previous detectors of a similar design are likely dominated by charge leakage along the side wall of the device. We saw only a small reduction in dark event rate with this biasing scheme, further suggesting that sidewall and edge-dominated processes are responsible for the majority of these events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗