Environment Insensitive Detection of Fissionable Material with A Short Pulse Neutron Source
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Podpaly, Y A.
Explore the source record for details and available documents.
New results suggest that changes observed in the intrinsic toroidal rotation influence the internal transport barrier (ITB) formation in the Alcator C-Mod tokamak [E. S. Marmar and Alcator C-Mod group, Fusion Sci. Technol. 51, 261 (2007)]. These arise when the resonance for ion cyclotron range of frequencies (ICRF) minority heating is positioned off-axis at or outside of the plasma half-radius. These ITBs form in a reactor relevant regime, without particle or momentum injection, with Ti Almost-Equal-To Te, and with monotonic q profiles (q{sub min} < 1). C-Mod H-mode plasmas exhibit strong intrinsic co-current rotation that increases with increasing stored energy without external drive. When the resonance position is moved off-axis, the rotation decreases in the center of the plasma resulting in a radial toroidal rotation profile with a central well which deepens and moves farther off-axis when the ICRF resonance location reaches the plasma half-radius. This profile results in strong E Multiplication-Sign B shear (>1.5 Multiplication-Sign 10{sup 5} rad/s) in the region where the ITB foot is observed. Gyrokinetic analyses indicate that this spontaneous shearing rate is comparable to the linear ion temperature gradient (ITG) growth rate at the ITB location and is sufficient to reduce the turbulent particle and energy transport. New and detailed measurement of the ion temperature demonstrates that the radial profile flattens as the ICRF resonance position moves off axis, decreasing the drive for the ITG the instability as well. These results are the first evidence that intrinsic rotation can affect confinement in ITB plasmas.
Ohmic energy confinement saturation is found to be closely related to core toroidal rotation reversals in Alcator C-Mod tokamak plasmas. Rotation reversals occur at a critical density, depending on the plasma current and toroidal magnetic field, which coincides with the density separating the linear Ohmic confinement regime from the saturated Ohmic confinement regime. The rotation is directed co-current at low density and abruptly changes direction to counter-current when the energy confinement saturates as the density is increased. Since there is a bifurcation in the direction of the rotation at this critical density, toroidal rotation reversal is a very sensitive indicator in the determination of the regime change. The reversal and confinement saturation results can be unified, since these processes occur in a particular range of the collisionality.
We have carried out a detailed study of the dependence of ICRF mode conversion flow drive (MCFD) on plasma and RF parameters. The flow drive efficiency is found to depend strongly on the {sup 3}He concentration in D({sup 3}He) plasmas, a key parameter separating the ICRF minority heating regime and mode conversion regime. At +90 deg. antenna phasing (waves in the co-I{sub p} direction) and dipole phasing, the driven flow is in the co-I{sub p} direction, and the change of the rotation velocity increases with both P{sub RF} and I{sub p}, and scales unfavorably vs. plasma density and antenna frequency. When MCFD is applied to I-mode plasmas, the plasma rotation increases until the onset of MHD modes triggered by large sawtooth crashes. Very high performance I-mode plasmas with H{sub ITER98,y2}{approx}1.4 and T{sub e0}{approx}8 keV have been obtained in these experiments.
Significant ion toroidal rotation (50km/s) has been measured by X-Ray spectroscopy for impurities in Alcator C-Mod during lower hybrid (LH) RF power injection. We investigate the relation between the computed toroidal momentum input from LH waves and the measured INITIAL change of ion toroidal rotation when the LH power is turned on. The relation may depend on the plasma current and magnetic configuration. Because of the fast build up time of the electron quasilinear plateau (<1 millisecond), the electron distribution function rapidly reaches steady state in which the electrons transfer momentum to the ions. The LH wave momentum input is computed from the self consistent steady state electron distribution function and a bounce-averaged quasilinear diffusion coefficient that are obtained by iterating a full wave code (TORLH) with a Fokker Plank code (CQL3D)
Direction reversals of intrinsic toroidal rotation have been observed in diverted Alcator C-Mod Ohmic L-mode plasmas following electron density ramps. For low density discharges, the core rotation is directed cocurrent, and reverses to countercurrent following an increase in the density above a certain threshold. Such reversals occur together with a decrease in density fluctuations with 2 cm{sup -1}{<=}k{sub {theta}}{<=}11 cm{sup -1} and frequencies above 70 kHz. There is a strong correlation between the reversal density and the density at which the Ohmic L-mode energy confinement changes from the linear to the saturated regime.