Search NASA⌕ Search

Engineering topics

Podsiadlo, P

Publications and source records attributed to Podsiadlo, P.

Multicomponent periodic nanoparticle superlattices.

In this article, we review the state-of-the-art in the preparation and characterization of multicomponent self-assembled superlattices of colloidal nanoparticles with core sizes in the range of 2-20 nm and interparticle spacing less than 2 nm down to intimate contact stemming from sintering. Several aspects of the field are discussed, including: structural organization, the role of particle size distribution, key interparticle forces at play, and methods of investigation of the structures. Contrary to the extensively studied colloidal crystals composed of microscale particles, the nanoparticles possess unique size-dependent properties, such as electronic, optical, or magnetic, which when combined into periodic structures can potentially lead to new collective states stemming from precise positioning of the nanocolloids. As such, we examine a number of emerging applications of this new class of metamaterials. Finally, we speculate on the potential impact of these materials, the new directions, and the challenges for the researchers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Automated selection of trabecular bone regions in knee radiographs

Osteoarthritic (OA) changes in knee joints can be assessed by analyzing the structure of trabecular bone (TB) in the tibia. This analysis is performed on TB regions selected manually by a human operator on x-ray images. Manual selection is time-consuming, tedious, and expensive. Even if a radiologist expert or highly trained person is available to select regions, high inter- and intraobserver variabilities are still possible. A fully automated image segmentation method was, therefore, developed to select the bone regions for numerical analyses of changes in bone structures. The newly developed method consists of image preprocessing, delineation of cortical bone plates (active shape model), and location of regions of interest (ROI). The method was trained on an independent set of 40 x-ray images. Automatically selected regions were compared to the ''gold standard'' that contains ROIs selected manually by a radiologist expert on 132 x-ray images. All images were acquired from subjects locked in a standardized standing position using a radiography rig. The size of each ROI is 12.8x12.8 mm. The automated method results showed a good agreement with the gold standard [similarity index (SI)=0.83 (medial) and 0.81 (lateral) and the offset=[-1.78, 1.27]x[-0.65,0.26] mm (medial) and [-2.15, 1.59]x[-0.58, 0.52] mm (lateral)]. Bland and Altman plots were constructed for fractal signatures, and changes of fractal dimensions (FD) to region offsets calculated between the gold standard and automatically selected regions were calculated. The plots showed a random scatter and the 95% confidence intervals were (-0.006, 0.008) and (-0.001, 0.011). The changes of FDs to region offsets were less than 0.035. Previous studies showed that differences in FDs between non-OA and OA bone regions were greater than 0.05. ROIs were also selected by a second radiologist and then evaluated. Results indicated that the newly developed method could replace a human operator and produces bone regions with an accuracy that is sufficient for fractal analyses of bone texture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗