Engineering topics
Polavaram, Krishna C.
Publications and source records attributed to Polavaram, Krishna C..
FFT-based model for irradiated aggregate microstructures in concrete
The concrete biological shield of light water reactors is exposed to neutron and gamma irradiation throughout its lifetime, which results in the long-term degradation of the concrete’s mechanical properties. Under neutron irradiation, the concrete’s aggregates are subjected to radiation-induced volumetric expansion (RIVE), which strongly depends on the mineral content of the aggregate and exhibits the largest expansion in silicate-bearing minerals. In this work, the authors used the fast Fourier transform-based code Microstructure-Oriented Scientific Analysis of Irradiated Concrete (MOSAIC) in 2D to model the expansion of five different aggregates provided by the Japan Concrete Aging Management Program (JCAMP). Comparable rock specimens were irradiated at the JEEP-II test reactor. The model uses realistic aggregate microstructure reconstruction based on high-resolution characterization images. The model accounts for anisotropic RIVE, thermal expansion, and the associated initiation and propagation of damage. The RIVE models are calibrated based on expansion data in the literature. The authors assume that damage occurs exclusively at interfaces between the particles that compose an aggregate and that these interfaces also exhibit swelling. Using a micromechanical model, the evolution of Young’s modulus with RIVE is calculated for each aggregate and compared with Russian irradiation data. The modeled linear expansion agrees well with the experimentally measured expansion. Furthermore, the model also predicts that anisotropic RIVE and thermal expansion result in an earlier onset of damage with neutron fluence than in the isotropic case.
Enabling phase quantification of anhydrous cements via Raman imaging
The phase composition of Portland cements is typically determined using conventional techniques like X-ray Diffraction (XRD) Rietveld analysis, optical microscopy point counting, and electron microscopy. However, these techniques have several limitations that may affect their accuracy in certain sample-specific scenarios. Here, we report a highly accurate phase quantification of 11 different types of commercial, anhydrous cements using a new and complementary technique: Raman imaging. Specifically, for the 4 principal phases, composition from our extensive data (250,000 Raman spectra per sample, error < 0.71%) and those obtained from XRD Rietveld and supplier data have high coefficients of determination (R{sup 2} > 0.98, mean deviation <2%). Additionally, we also quantify 8 secondary phases present in cement clinkers (gypsum, anhydrite, bassanite, syngenite, dolomite, calcite, quartz, and portlandite) with a high degree of confidence, thereby demonstrating that Raman imaging is a highly versatile tool for anhydrous phase quantification in a broad variety of cements.
High-fidelity and high-resolution phase mapping of granites via confocal Raman imaging
Abstract In physical sciences such as chemistry and earth sciences, specifically for characterization of minerals in a rock, automated, objective mapping methods based on elemental analysis have replaced traditional optical petrography. However, mineral phase maps obtained from these newer approaches rely on conversion of elemental compositions to mineralogical compositions and thus cannot distinguish mineral polymorphs. Secondly, these techniques often require laborious sample preparations such as sectioning, polishing, and coating which are time-consuming. Here, we develop a new Raman imaging protocol that is capable of mapping unpolished samples with an auto-focusing Z-mapping feature that allows direct fingerprinting of different polymorphs. Specifically, we report a new methodology for generating high fidelity phase maps by exploiting characteristic peak intensity ratios which can be extended to any multi-phase, heterogenous system. Collectively, these enhancements allow us to rapidly map an unpolished granite specimen (~ 2 × 2 mm) with an exceptionally high accuracy (> 97%) and an extremely fine spatial resolution (< 0.3–2 µm).