Search NASA⌕ Search

Engineering topics

Poole, B

Publications and source records attributed to Poole, B.

Engineering Prototype for a Compact Medical Dielectric Wall Accelerator

A compact accelerator system architecture based on the dielectric wall accelerator (DWA) for medical proton beam therapy has been developed by the Compact Particle Acceleration Corporation (CPAC). The major subsystems are a Radio Frequency Quadrupole (RFQ) injector linac, a pulsed kicker to select the desired proton bunches, and a DWA linear accelerator incorporating a high gradient insulator (HGI) with stacked Blumleins to produce the required acceleration energy. The Blumleins are switched with solid state laser-driven optical switches integrated into the Blumlein assemblies. Other subsystems include a high power pulsed laser, fiber optic distribution system, electrical charging system, and beam diagnostics. An engineering prototype has been constructed and characterized, and these results will be used within the next three years to develop an extremely compact 150 MeV system capable of modulating energy, beam current, and spot size on a shot-to-shot basis. This paper presents the details the engineering prototype, experimental results, and commercialization plans.

43 PARTICLE ACCELERATORS↗

A Single Pulse Sub-Nanosecond Proton RFQ

A Radio Frequency Quadrupole (RFQ) linac system has been developed to provide a single pulse of 2 MeV protons with a beam pulse width of {approx}300 ps and a charge of 30 pC, either for injection into a pulsed Dielectric Wall Accelerator or for bombardment of a target to produce a fast neutron pulse. The 1.2 m long RFQ structure operates at 425 MHz and bunches and accelerates a single 2.35 ns beam pulse injected into it at 35 keV using a parallel plate deflector placed directly in front of the RFQ entrance. The input acceptance properties of the RFQ allow a simple dc bias voltage on the plates to block acceleration of the unwanted beam, with a short rf voltage pulse applied to null the deflection field for the ions within the 8 mm 'kicker' plate length. The use of the RFQ as the accelerating structure allows one to efficiently produce a large charge in a single sub-ns bunch. In addition, the kicker can also be used without the dc bias voltage to produce a 'notch' in the normal RFQ output beam for synchrotron injection.

43 PARTICLE ACCELERATORS↗

Beam Transport in a Compact Dielectric Wall Accelerator for Proton Therapy

To attain the highest accelerating gradient in the compact dielectric wall (DWA) accelerator, the DWA will be operated in the 'virtual' traveling mode with potentially non-uniform and time-dependent axial accelerating field profiles, especially near the DWA entrance and exit, which makes beam transport challenging. We have established a baseline transport case without using any external lenses. Results of simulations using the 3-D, EM PIC code, LSP indicate that the DWA transport performance meets the medical specifications for proton treatment. Sensitivity of the transport performance to Blumlein block failure will be presented.

43 PARTICLE ACCELERATORS↗

SECONDARY ELECTRON TRAJECTORIES IN HIGH-GRADIENT VACUUM INSULATORS WITH FAST HIGH-VOLTAGE PULSES

Vacuum insulators composed of alternating layers of metal and dielectric, known as high-gradient insulators (HGIs), have been shown to withstand higher electric fields than conventional insulators. Primary or secondary electrons (emitted from the insulator surface) can be deflected by magnetic fields from external sources, the high-current electron beam, the conduction current in the transmission line, or the displacement current in the insulator. These electrons are deflected either toward or away from the insulator surface and this affects the performance of the vacuum insulator. This paper shows the effects of displacement current from short voltage pulses on the performance of high gradient insulators. Generally, vacuum insulator failure is due to surface flashover, initiated by electrons emitted from a triple junction. These electrons strike the insulator surface thus producing secondary electrons, and can lead to a subsequent electron cascade along the surface. The displacement current in the insulator can deflect electrons either toward or away from the insulator surface, and affects the performance of the vacuum insulator when the insulator is subjected to a fast high-voltage pulse. Vacuum insulators composed of alternating layers of metal and dielectric, known as high-gradient insulators (HGIs), have been shown to withstand higher electric fields than conventional insulators. HGIs, being tolerant of the direct view of high-current electron and ion beams, and having desirable RF properties for accelerators, are a key enabling technology for the dielectric-wall accelerators (DWA) being developed at Lawrence Livermore National Laboratory (LLNL). Characteristically, insulator surface breakdown thresholds go up as the applied voltage pulse width decreases. To attain the highest accelerating gradient in the DWA, short accelerating voltage pulses are only applied locally, along the HGI accelerator tube, in sync with the charged particle bunch, and the effects of displacement current on trajectories of electrons emitted from HGI surface are particularly interesting. This paper presents simulated electron trajectories experiencing either constant or short-duration applied voltage pulses. Comparisons of these trajectories clearly indicate the importance of the voltage pulse shape, especially the rise time, in the flashover initiation process for HGIs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ULTRA-COMPACT ACCELERATOR TECHNOLOGIES FOR APPLICATION IN NUCLEAR TECHNIQUES

We report on compact accelerator technology development for potential use as a pulsed neutron source quantitative post verifier. The technology is derived from our on-going compact accelerator technology development program for radiography under the US Department of Energy and for a clinic sized compact proton therapy systems under an industry sponsored Cooperative Research and Development Agreement. The accelerator technique relies on the synchronous discharge of a prompt pulse generating stacked transmission line structure with the beam transit. The goal of this technology is to achieve approx10 MV/m gradients for 10 s of nanoseconds pulses and approx100 MV/m gradients for approx1 ns systems. As a post verifier for supplementing existing x-ray equipment, this system can remain in a charged, stand-by state with little or no energy consumption. We describe the progress of our overall component development effort with the multilayer dielectric wall insulators (i.e., the accelerator wall), compact power supply technology, kHz repetition-rate surface flashover ion sources, and the prompt pulse generation system consisting of wide-bandgap switches and high performance dielectric materials.

43 PARTICLE ACCELERATORS↗

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, SiC photoconductive switches and compact proton sources. Applications of the DWA accelerator to problems in homeland security will also be discussed.

43 PARTICLE ACCELERATORS↗

COMPACT PROTON INJECTOR AND FIRST ACCELERATOR SYSTEM TEST FOR COMPACT PROTON DIELECTRIC WALL CANCER THERAPY ACCELERATOR

A compact proton accelerator for cancer treatment is being developed by using the high-gradient dielectric insulator wall (DWA) technology [1-4]. We are testing all the essential DWA components, including a compact proton source, on the First Article System Test (FAST). The configuration and progress on the injector and FAST will be presented.

43 PARTICLE ACCELERATORS↗

STATUS OF THE DIELECTRIC WALL ACCELERATOR

The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.

43 PARTICLE ACCELERATORS↗