Search NASA⌕ Search

Engineering topics

Popecki, M.

Publications and source records attributed to Popecki, M..

Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD TM ) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The results of this test confirmed that the coarse-pixelated (2.5 × 2.5 cm 2 pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

Performance of photosensors in a high-rate environment for gas Cherenkov detectors

We report the solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm 2 at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small Cherenkov counter in a high-rate environment up to 60 kHz/cm 2 , in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the beam test performance of our counter device.

47 OTHER INSTRUMENTATION↗

Fermilab Test Beam Facility Annual Report: FY19

This Technical Memorandum (TM) summarizes the Fermilab Test Beam Faciltiy (FTBF) operations for FY2019. It is one of a series of annual publications intended to gather information in one place. This TM discusses the experiments performed at the Test Beam from November 2018 to July 2019. The experiments are listed in Table 1. Each experiment wrote a summary that was edited for clarity and is included in this report.

43 PARTICLE ACCELERATORS↗

Accelerator measurement of NaI response to medium energy neutrons and application to a satellite-borne spectrometer

We report on the response of a prototype detector to medium energy neutrons. The neutrons were produced by n-p scattering of a neutron beam on a hydrogen target. The measurements provide unique data on the efficiency and response of large NaI scintillators to neutrons in the energy range 36-709 MeV. We apply the results to the high-energy mode of the Gamma-Ray Spectrometer (GRS) on the Solar Maximum Mission satellite by estimating its efficiency for neutron detection. This estimate is compared to earlier Monte Carlo calculations of the GRS efficiency.

Dunphy, P. P.↗