Search NASASearch

Engineering topics

Porst, J. P.

Publications and source records attributed to Porst, J. P..

Large Format Transition Edge Sensor Microcalorimeter Arrays

We have produced a variety of superconducting transition edge sensor array designs for microcalorimetric detection of x-rays. Designs include kilopixel scale arrays of relatively small sensors (approximately 75 micron pitch) atop a thick metal heat sinking layer as well as arrays of membrane-isolated devices on 250 micron and up to 600 micron pitch. We discuss fabrication and performance of microstripline wiring at the small scales achieved to date. We also address fabrication issues with reduction of absorber contact area in small devices.

Chervenak, J. A.

Superconducting Effects in Optimization of Magnetic Penetration Thermometers for X-ray Microcalorimeters

Like MMCs, MPTs enable high energy microcalorimeters with zero bias power dissipation and potential resolution < 1 eV. MPTs can provide d(phi)/dT as large as 1000 (Phi)(sub 0)/K, with no excess noise, thereby reducing the importance of SQUID noise. Long coherence length in a Type-I superconducting MoAu film offers multiple advantages for efficient flux expulsion in MPT. Region of steepest d(phi)/dT is the Meissner effect in the small device; flux is expelled/penetrates to minimize free energy. Steepness of transition can be engineered with choice of film thickness and coil pitch relative to lambda(sub eff)(0), ratio of T/T(sub c), and bias circuit inductance.

Stevenson, T. R.

Performance of Large Format Transition Edge Sensor Microcalorimeter Arrays

We have produced a variety of superconducting transition edge sensor array designs for microcalorimetric detection of x-rays. Arrays are characterized with a time division SQUID multiplexer such that greater than 10 devices from an array can be measured in the same cooldown. Designs include kilo pixel scale arrays of relatively small sensors (-75 micron pitch) atop a thick metal heatsinking layer as well as arrays of membrane-isolated devices on 250 micron and up to 600 micron pitch. We discuss fabrication and performance of microstripline wiring at the small scales achieved to date. We also address fabrication issues with reduction of absorber contact area in small devices.

Chervenak, J. A.

The Transition-Edge-Sensor Array for the Micro-X Sounding Rocket

The Micro-X sounding rocket program will fly a 128-element array of transition-edge-sensor microcalorimeters to enable high-resolution X-ray imaging spectroscopy of the Puppis-A supernova remnant. To match the angular resolution of the optics while maximizing the field-of-view and retaining a high energy resolution (< 4 eV at 1 keV), we have designed the pixels using 600 x 600 sq. micron Au/Bi absorbers, which overhang 140 x 140 sq. micron Mo/Au sensors. The data-rate capabilities of the rocket telemetry system require the pulse decay to be approximately 2 ms to allow a significant portion of the data to be telemetered during flight. Here we report experimental results from the flight array, including measurements of energy resolution, uniformity, and absorber thermalization. In addition, we present studies of test devices that have a variety of absorber contact geometries, as well as a variety of membrane-perforation schemes designed to slow the pulse decay time to match the telemetry requirements. Finally, we describe the reduction in pixel-to-pixel crosstalk afforded by an angle-evaporated Cu backside heatsinking layer, which provides Cu coverage on the four sidewalls of the silicon wells beneath each pixel.

Eckart, M. E.

Magnetically Coupled Microcalorimeters

Magnetic calorimeters have been under development for over 20 years targeting a wide variety of different applications that require very high resolution spectroscopy. They have a number of properties that distinguish them from other 10w temperature detectors. In this paper we review these properties and emphasize the types of application to which they are most suited. We will describe what has been learned about the best materials, geometries, and read-out amplifiers and our understanding of the measured performance and theoretical limits. While most magnetic calorimeter research has concentrated on the use of paramagnets to provide the temperature sensitivity, recently magnetically coupled microcalorimeters have been in development that utilize the diamagnetic response of superconductors. We will contrast some of the properties of the two different magnetic sensor types.

Bandler, S. R.

Performance of Magnetic Penetration Thermometers for X-Ray Astronomy

The ideal X-ray camera for astrophysics would have more than a million pixels and provide an energy resolution of better than leV FWHM for energies up to 10 keY. We have microfabricated and characterized thin-film magnetic penetration thermometers (MPTs) that show great promise towards meeting these capabilities. MPTs operate in similar fashion to metallic magnetic calorimeters (MMCs), except that a superconducting sensor takes the place of a paramagnetic sensor and it is the temperature dependence of the superconductor's diamagnetic response that provides the temperature sensitivity. We present a description of the design and performance of our prototype thin-film MPTs with MoAu bilayer sensors, which have demonstrated an energy resolution of approx 2 eV FWHM at 1.5 keY and 4.3 eV FWHM at 5.9 keY.

Nagler, P. C.

Multi-Absorber Transition-Edge Sensors for X-Ray Astronomy Applications

We are developing multi-absorber Transition-Edge Sensors (TESs) for applications in x-ray astronomy. These position-sensitive devices consist of multiple x-ray absorbers each with a different thermal coupling to a single readout TES. Heat diffusion between the absorbers and the TES gives rise to a characteristic pulse shape corresponding to each absorber element and enables position discrimination. The development of these detectors is motivated by a desire to maximize focal plane arrays with the fewest number of readout channels. In this contribution we report on the first results from devices consisting of nine) 65 X 65 sq. microns Au x-ray absorbers) 5 microns thick. These are coupled to a single 35 X 35 sq. microns Mo/Au bilayer TES. These devices have demonstrated full-width-half-maximum (FWHM) energy resolution of 2.1 eV at 1.5 keV) 2.5 eV at 5.9 keV and 3.3 eV at 8 keV. This is coupled with position discrimination from pulse shape over the same energy range. We use a finite-element model to reproduce the measured pulse shapes and investigate the detector non-linearity with energy) which impacts on the devices position sensitivity and energy resolution.

Smith, S. J.