Search NASA⌕ Search

Engineering topics

Porter, Daniel

Publications and source records attributed to Porter, Daniel.

Effect of lattice orientation on compressive properties of selective laser sintered nylon lattice coupons

As AM lattices become more popular in medical devices, it is important to consider how lattice design parameters affect the mechanical integrity and performance of a device. This research investigated the effect of lattice orientation on the compressive mechanical response of five common lattice geometries: Hexagonal Honeycomb (Hex), Diamond, Voronoi Tessellation Method (VTM), sheet-based Gyroid, and Face-Centered-Cubic (FCC). Samples were tested at two relative densities and eight orientations, printed in Nylon 12 (PA2200) on an EOS P396. The mechanical response was compared to simulated finite element analysis (FEA) response for Hex and FCC lattices. Hex lattices displayed significant orientation dependance. Diamond lattices demonstrated some orientation dependance when at a lower relative density. Gyroid, FCC, and VTM all displayed minimal orientation dependance. Increasing lattice relative density appeared to reduce anisotropy among tested orientations of all lattice geometries except Hex. FEA simulations were able to produce a trend response that matched the mechanical response trends based on the investigated orientations. Furthermore, these results support the need for multi axial lattice mechanical test considerations. It also bolsters the need for lattice FEA models to have a sufficient comparator when identifying “worst-case” lattice test scenarios.

36 MATERIALS SCIENCE↗

Influence of topology optimization parameters on the mechanical response of an additively manufactured test structure

Topology Optimization (TO) determines a material distribution within a domain under given conditions and design constraints, and generally generates complex geometries as a result. Complementary to TO, Additive Manufacturing (AM) offers the ability to fabricate complex geometries which may be difficult to manufacture using traditional techniques such as milling. AM has been used in multiple industries including the medical devices area. Hence, TO may be used to create patient-matched devices where the mechanical response is catered to a particular patient. Furthermore, during a medical device regulatory 510(k) pathway, demonstrating that worst-cases are known and tested is critical to the review process. Using TO and AM to predict worst-case designs for subsequent performance testing may be challenging and does not appear to have been thoroughly explored. Investigating the effects of TO input parameters when AM is employed may be the first step in determining the feasibility of predicting these worst-cases.

36 MATERIALS SCIENCE↗

Benchtop assessment of sealing efficacy and breathability of additively manufactured (AM) face masks

The onset of the 2019 novel coronavirus disease (COVID-19) led to a shortage of personal protective equipment (PPE), medical devices, and other medical supplies causing many stakeholders and the general public alike to turn to additive manufacturing (AM) as a stopgap when normally accessible devices were not available. However, without a method to test these AM constructs, there continued to be a disconnect between AM suppliers and the community’s needs. The objective of this study was to characterize the pressure drop and leakage of four different publicly available AM face mask models with two filter material combinations, as well as to investigate the impact of frame modification techniques including the use of foam strips and hot-water face forming to improve fit when the masks are donned on manikin head forms. AM face mask frame designs were downloaded from public repositories during the early stages of the COVID-19 pandemic. AM face masks were fabricated and tested on manikin head forms within a custom chamber containing dry aerosolized NaCl. Pressure drops, particle penetration, and leakage were evaluated for various flow rates and NaCl concentrations. Results indicated that filter material combination and frame modification played a major role in the overall performance of the AM face masks studied. Filter material combinations showed improved performance when high filtration fabric was used, and the cross-sectional area of the fabric was increased. AM frame modifications appeared to improve AM face mask leakage performance by as much as 69.6%.

36 MATERIALS SCIENCE↗

A high-speed, high-performance, microfabricated comprehensive two-dimensional gas chromatograph

A small, consumable-free, low-power, ultra-high-speed comprehensive GC×GC system consisting of microfabricated columns, nanoelectromechanical system (NEMS) cantilever resonators for detection, and a valve-based stop-flow modulator is demonstrated. The separation of a highly polar 29-component mixture covering a boiling point range of 46 to 253 °C on a pair of microfabricated columns using a Staiger valve manifold in less than 7 seconds, and just over 4 seconds after the ensemble holdup time is demonstrated with a downstream FID. The analysis time of the second dimension was 160 ms, and peak widths in the second dimension range from 10–60 ms. A peak capacity of just over 300 was calculated for a separation of just over 6 s. Data from a continuous operation testing over 40 days and 20 000 runs of the GC×GC columns with the NEMS resonators using a 4-component test set is presented. As a result, the GC×GC-NEMS resonator system generated second-dimension peak widths as narrow as 8 ms with no discernable peak distortion due to under-sampling from the detector.

47 OTHER INSTRUMENTATION↗