Search NASASearch

Engineering topics

Poultney, S. K.

Publications and source records attributed to Poultney, S. K..

At least 19 records

Exact modeling of lineshape and wavenumber variations for off-axis detectors in Fourier transform spectrometers (FTS) sensor systems

The utilization of detector arrays in the focal planes of FTS sensor systems allows simultaneous spectral and spatial measurements. However, spectral lineshapes and wavenumber locations depend upon the size and location of the detector elements with respect to the Haidinger fringe pattern of the FTS sensor. These spectral distortions can be generalized as a shift and shape change of the FTS sensor lineshape. Depending on the distortions that can be tolerated, a degree of field-widening can be obtained for a given Haidinger fringe pattern. An exact model for predicting the FTS lineshape distortions is presented. The model is applied to several contemporary applications in order to quantify the magnitude of distortions to be expected.

Niple, E.

Quantitative remote measurements of pollutants from stationary sources using Raman lidar

The several advantages of Raman lidar for remote measurements of stationary source emissions were quantitatively evaluated using a calibration tank at a distance of 300 m at night. Measurements of approximately 10 to the 3rd ppm SO2 with a 12% accuracy were demonstrated in an observation time of 15 min using a 1.5-J ruby laser at 30 pulses/min, 6-m range resolution, interference filters, photon counting detection, and a 20-cm receiver. Measurement accuracy was checked by measuring known concentrations of SO2 in the tank, by tuning the interference filters through the SO2 Raman line, and by varying the CO2 concentration to very high levels during the SO2 measurements. Evaluation of the seriousness of induced fluorescence from plume aerosols failed due to the inability to simulate the plume aerosols.

Poultney, S. K.

A theoretical/experimental program to develop active optical pollution sensors: Quantitative remote Raman lidar measurements of pollutants from stationary sources

Typical pollutant gas concentrations at the stack exits of stationary sources can be estimated to be about 500 ppm under the present emission standards. Raman lidar has a number of advantages which makes it a valuable tool for remote measurements of these stack emissions. Tests of the Langley Research Center Raman lidar at a calibration tank indicate that night measurements of SO2 concentrations and stack opacity are possible. Accuracies of 10 percent are shown to be achievable from a distance of 300 m within 30 min integration times for 500 ppm SO2 at the stack exits. All possible interferences were examined quantitatively (except for the fluorescence of aerosols in actual stack emissions) and found to have negligible effect on the measurements. An early test at an instrumented stack is strongly recommended.

Poultney, S. K.

A theoretical/experimental program to develop active optical pollution sensors, part 2

Progress is reported on experimental investigations of Lidar and the application of Lidar to environmental and atmospheric science. Specifically the following programs are considered: calibration and application of the LaRC 48-inch Lidar; efficient and certain detection of SO2 and other gases in the calibration tank using the Raman Stack Monitor Lidar; the potential of Lidar remote sensing from the space shuttle; and the planning and mounting of efforts to realize the promise of backscatter differential absorption Lidar.

Poultney, S. K.

Testing the linearity of response of gated photomultipliers in wide dynamic range laser radar systems

Laser radar data acquisition systems have been utilized in conjunction with a light emitting diode to evaluate photomultipliers for laser radar use. Light pulses with an exponential decay rate of approximately one decade per sixty microseconds, as well as other pulse shapes, were used to drive the tubes. Properties studied in the analog mode include nonlinearity at high output currents, transient behavior upon gating, gate holdoff, dynamic range limitations because of light-induced noise, and the effect of dynode gating on tubes without a focus grid. Some of these properties were also studied in the photon counting mode, along with single photoelectron pulse shape and afterpulsing. A brief description of the laser radar technique of atmospheric measurements is included.

Hunt, W. H.

Single photon detection and sub-nanosecond timing resolution with RCA C31034 photomultiplier

The very high quantum efficiencies and low dark count rates achieved with selected RCA C31034 photomultipliers make them attractive candidates for single photoelectron fast timing experiments. Single photoelectron plateau counting and a timing resolution of 0.60 nsec (FWHM) were obtained using fast amplifiers, constant fraction timing discriminators, and a pulsed light emitting diode. A redesign of the C31034 incorporating features of the very fast C31024 is suggested to yield even better timing resolution.

Reisse, R.

The lunar laser ranging experiment.

The scientific objectives achievable through high-accuracy range measurements to lunar retroreflectors are considered. A specific study of design questions related to the operation of retroreflectors on the lunar surface indicated that a reflector panel containing a number of solid fused silica corner reflectors would be capable of maintaining essentially diffraction limited performance under direct solar illumination. Initial Apollo 11 observations are discussed together with the installation of additional lunar retroreflectors in connection with the Luna 17, Apollo 14, Apollo 15, and Luna 21 missions. Range measurements at the McDonald Observatory are considered along with new results from lunar range data, and prospects regarding future lunar ranging stations.

Bender, P. L.

A study of the origin, nature, and behavior of particulate matter and metallic atoms in the mesosphere, lower thermosphere, and at the mesopause

In a study of particulate matter and metallic atoms in the vicinity of the mesopause, three areas have received the most effort. These areas are: the significance of cometary dust influxes to the earth's atmosphere; the relation of nightglows to atmospheric motions and aerosols; and the feasibility of using an airborne resonant scatter lidar to study polar noctilucent clouds, the sodium layer, and fireball dust.

Poultney, S. K.

Single photon detection and timing in the Lunar Laser Ranging Experiment.

The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

Poultney, S. K.

Single photon detection and timing - Experiments and techniques.

Single photon detection and timing means essentially the detection and timing of a single photoelectron released by light from a photosensitive surface of a photomultiplier, channel multiplier, avalanche multiplier photodiode, or other photodevice. Necessary photodevice gain and detection circuits, mechanisms and statistics of photodevice gain, photodevice and background noise and their reduction, and practical photodevice techniques and photon detection performance tests are discussed. Fast timing with single photons, and single photon detection with moderate timing requirements are considered.

Poultney, S. K.

Sub-nanosecond ranging possibilities of optical radar at various signal levels and transmitted pulse widths

The behavior of the photomultiplier is considered, as well as the method of derivation of the photomultiplier output pulse and its relation to the reflected light pulse width and amplitude, and the calibration of range precision and accuracy. Pulsed laser radars with light pulse widths of 30, 3, and 0.1 nanosec a considered, with the 0.1 nanosec system capable of highest precision in several modes of operation, including a high repetition rate, single photoelectron reception mode. An alternate calibration scheme using a fast, triggerable light pulser is described in detail.

Poultney, S. K.