Search NASA⌕ Search

Engineering topics

Povilus, A.

Publications and source records attributed to Povilus, A..

Measuring characteristic differences between high- and low-performing discharges on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF

A dense plasma focus (DPF) is a compact coaxial plasma gun, which completes its discharge as a Z-pinch, producing short (<100 ns) pulses of ions, x rays, and/or neutrons. Lawrence Livermore National Laboratory recently constructed and began operating a new device, the MJOLNIR (MegaJOuLe Neutron Imaging Radiography) DPF, which is designed for single-pulse flash neutron radiography. This device has achieved neutron yields of up to 4.1×10 11 neutrons/pulse at 3.3 MA peak current, and higher-current commissioning is under way. Like most DPFs, MJOLNIR exhibits variable yields in some configurations. Here, we present evidence of the role of parasitic current paths within the gun in stochastically influencing the yield. First through “conditioning shots,” where new hardware has been introduced, we show that increased run-down and run-in speeds correlate with higher yields. These observations are consistent with current being delivered to the electrodes but not to the main plasma sheath, degrading the implosion-driving force. Once nominal conditions are established, we correlate low-performing discharges with smaller current dip and associated voltage spike for a fixed machine configuration. A snow-plow model is able to recreate small-magnitude current dips through the introduction of a parasitic current path, and particle-in-cell simulations establish how parasitic current paths lower the ion beam energy available to produce neutrons. Finally, we observe an increased likelihood of shots with low yield and smaller current dip with increasing fill pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Maximizing neutron yields by scaling hollow diameter of a dense plasma focus anode [Neutron yield maximization and anode surface damage characterization by scaling hollow diameters of a DPF anode]

Experiments were performed to maximize the neutron yield from a 2 kJ dense plasma focus (DPF) and characterize the amount of copper sputtered from the surface of an anode by varying the diameter of the anodes’ on-axis hollow. The hollow is a void in the copper material along the longitudinal axis of the anode. All the anodes had an outer diameter of 1.2 in. and the diameter of the hollow varied from 0 in. (no hollow) to 1 in. The anodes with a hollow produced a greater number of neutrons per discharge than the anode without a hollow. Over 40 discharges, the hollow anode that yielded the most neutrons (9.1±0.4×10 6 neutrons per discharge produced with the 0.75 in. hollow) produced >6 times more neutrons than the anode with no hollow. A qualitative observation of the anodes after 130 discharges showed less surface damage on anodes with a larger hollow. Quantitative sputter measurements were performed by characterizing the amount of copper sputtered onto on-axis quartz targets for three newly machined anodes, each with a particular hollow diameter. The quantitative results matched the qualitative observations: the copper sputter was reduced using larger hollows. Finally, the largest hollow sputtered 17±1.0 nm/sr/discharge of copper, a reduction of 69% compared to the anode with the most damage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AmBe Final Project Report on Simulations

In this project we examine the feasibility of using a dense plasma focus (DPF) to accelerate helium into a beryllium target as a way to replace AmBe sources with an accelerator source of similar neutron spectrum. Our group at LLNL, in collaboration with Voss Scientific, developed a fully kinetic model of DPF z-pinch plasmas in order to accurately predict ion beam spectra and neutron yields. Our group uses this tool as a guide for experiments, and also as a predictive tool to access regimes that would be time-consuming or expensive to try experimentally. In this report, we summarize the simulations that were performed during the course of this feasibility study. These simulations include the calculation of a DPF neutron spectrum based on a simulated ion beam spectrum, a pressure scan with optimized anode length, a sensitivity study to see how much the model depends on the MHD switch time, and initial simulations of the plasma breakdown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An experimental limit on the charge of antihydrogen

The properties of antihydrogen are expected to be identical to those of hydrogen, and any differences would constitute a profound challenge to the fundamental theories of physics. The most commonly discussed antiatom-based tests of these theories are searches for antihydrogen-hydrogen spectral differences (tests of CPT (charge-parity-time) invariance) or gravitational differences (tests of the weak equivalence principle). Here we, the ALPHA Collaboration, report a different and somewhat unusual test of CPT and of quantum anomaly cancellation. A retrospective analysis of the influence of electric fields on antihydrogen atoms released from the ALPHA trap finds a mean axial deflection of 4.1±3.4 mm for an average axial electric field of 0.51 V mm –1 . Combined with extensive numerical modelling, this measurement leads to a bound on the charge Qe of antihydrogen of Q=(–1.3±1.1±0.4) × 10 –8 . Here, e is the unit charge, and the errors are from statistics and systematic effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Autoresonant-spectrometric determination of the residual gas composition in the ALPHA experiment apparatus

Knowledge of the residual gas composition in the ALPHA experiment apparatus is important in our studies of antihydrogen and nonneutral plasmas. A technique based on autoresonant ion extraction from an electrostatic potential well has been developed that enables the study of the vacuum in our trap. Computer simulations allow an interpretation of our measurements and provide the residual gas composition under operating conditions typical of those used in experiments to produce, trap, and study antihydrogen. The methods developed may also be applicable in a range of atomic and molecular trap experiments where Penning-Malmberg traps are used and where access is limited.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaporative cooling of antiprotons for the production of trappable antihydrogen

We describe the implementation of evaporative cooling of charged particles in the ALPHA apparatus. Forced evaporation has been applied to cold samples of antiprotons held in Malmberg-Penning traps. Temperatures on the order of 10 K were obtained, while retaining a significant fraction of the initial number of particles. We have developed a model for the evaporation process based on simple rate equations and applied it succesfully to the experimental data. We have also observed radial re-distribution of the clouds following evaporation, explained by simple conservation laws. We discuss the relevance of this technique for the recent demonstration of magnetic trapping of antihydrogen.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Centrifugal Separation and Equilibration Dynamics in an Electron-Antiproton Plasma

Charges in cold, multiple-species, non-neutral plasmas separate radially by mass, forming centrifugally separated states. Here, we report the first detailed measurements of such states in an electron-antiproton plasma, and the first observations of the separation dynamics in any centrifugally separated system. While the observed equilibrium states are expected and in agreement with theory, the equilibration time is approximately constant over a wide range of parameters, a surprising and as yet unexplained result. Electron-antiproton plasmas play a crucial role in antihydrogen trapping experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Autoresonant Excitation of Antiproton Plasmas

We demonstrate controllable excitation of the center-of-mass longitudinal motion of a thermal antiproton plasma using a swept-frequency autoresonant drive. When the plasma is cold, dense, and highly collective in nature, we observe that the entire system behaves as a single-particle nonlinear oscillator, as predicted by a recent theory. In contrast, only a fraction of the antiprotons in a warm plasma can be similarly excited. Antihydrogen was produced and trapped by using this technique to drive antiprotons into a positron plasma, thereby initiating atomic recombination.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗