Search NASASearch

Engineering topics

Powers, Charles E.

Publications and source records attributed to Powers, Charles E..

The Neutron Star Interior Composition Explorer (NICER): Design and Development

During 2014 and 2015, NASA's Neutron star Interior Composition Explorer (NICER) mission proceeded successfully through Phase C, Design and Development. An X-ray (0.2{12 keV) astrophysics payload destined for the International Space Station, NICER is manifested for launch in early 2017 on the Commercial Resupply Services SpaceX-11 flight. Its scientific objectives are to investigate the internal structure, dynamics, and energetics of neutron stars, the densest objects in the universe. During Phase C, flight components including optics, detectors, the optical bench, pointing actuators, electronics, and others were subjected to environmental testing and integrated to form the flight payload. A custom-built facility was used to co-align and integrate the X-ray \concentrator" optics and silicon-drift detectors. Ground calibration provided robust performance measures of the optical (at NASA's Goddard Space Flight Center) and detector (at the Massachusetts Institute of Technology) subsystems, while comprehensive functional tests prior to payload-level environmental testing met all instrument performance requirements. We describe here the implementation of NICER's major subsystems, summarize their performance and calibration, and outline the component-level testing that was successfully applied.

SEXTANT

Implementation of NASA Materials and Processes Requirements at the Goddard Space Flight Center

This slide presentation reviews the history and current practices of the Materials Engineering Branch (MEB) at the Goddard Space Flight Center. Included in the presentation is a review of the general Materials and Processes (M&P) requirements in the NASA-STD-6016. The work that the Materials Engineering Branch does to support GSFC Projects is also reviewed. The Materials Engineering Branch capabilities are listed, the expertise that is available to GSFC projects is also listed. Included in the backup slides are forms that the MEB uses to identify the materials in the spacecraft under development.

Powers, Charles E.

Effects of Manufacturing and Deployment on Thin Films for the NGTS Sunshade

The Next Generation Space Telescope (NGST) is being developed as an advanced astronomical observatory. The NGST proposes to utilize several thin film membrane layers to create a shield for protection of the telescope from solar thermal energy and stray light, The shield will take the form of a polygon, approximately 15 x 30 m, with individual membrane layers positioned so that they do not come in contact with one another. The membrane shield will be deployed and supported by a series of booms, which will be packed into a small volume for launch. Finally, the shield will be deployed on orbit. Several film materials are being considered for the membrane shield, including CPI, Kapton E, Kapton RN, and Upilex. Each of these polyimide materials was tested to determine their durability over the 10-year mission. New facets of materials testing have been introduced in this study to develop performance data with greater realism to actual use, particularly that of degradation from packing, launch and deployment processing. Materials were exposed to handling that simulated the life of the materials from manufacture through deployment with standardized fixtures and then exposed to a simulated, L2, 10-year radiation environment. Mechanical and thermal radiative properties were measured before and after each phase of testing. This paper summarizes the program and test results.

Wooldridge, Eve M.

Degradation of Teflon(tm) FEP Following Charged Particle Radiation and Rapid Thermal Cycling

During the Second Servicing Mission (SM2) of the Hubble Space Telescope (HST) severe degradation was observed on the outer layer of the thermal control blankets. Astronaut observations and photographs revealed large cracks in the metallized Teflon FEP (fluorinated ethylene propylene), the outer layer of the multi-layer insulation (MLI), in many locations around the telescope. In an effort to understand what elements of the space environment might cause such damage, pristine Teflon' FEP was tested for durability to radiation and thermal cycling. Specimens were subjected to electron and proton fluences comparable to those experienced by HST and were subsequently thermal cycled in a custom-built rapid thermal cycle chamber. Tensile tests of the specimens showed that radiation followed by thermal cycling significantly reduced the ultimate strength and elongation of Teflon FEP.

Townsend, Jacqueline A.

Degradation of Teflon(tm) FEP Following Charged Particle Radiation and Rapid Thermal Cycling

During the Second Servicing Mission (SM2) of the Hubble Space Telescope (HST) severe degradation was observed on the outer layer of the thermal control blankets. Astronaut observations and photographs revealed large cracks in the metallized Teflon' FEP (fluorinated ethylene propylene), the outer layer of the multi-layer insulation (MLI), in many locations around the telescope. In an effort to understand what elements of the space environment might cause such damage, pristine Teflon(registered trademark) FEP was tested for durability to radiation and thermal cycling. Specimens were subjected to electron and proton fluences comparable to those experienced by HST and were subsequently thermal cycled in a custom-built rapid thermal cycle chamber. Tensile tests of the specimens showed that radiation followed by thermal cycling significantly reduced the ultimate strength and elongation of Teflon(registered trademark) FEP.

Townsend, Jacqueline A.

The Advanced Microwave Sounding Unit-A: Antenna Number 2 Bearing Assembly Life Test

Four bearing assemblies, lubricated with Apiezon C oil with 5% lead naphthenate (PbNp), were life tested in support of the Advanced Microwave Sounding Unit-A (AMSU-A). These assemblies were tested continuously for five to six years using the scanning pattern of the flight instrument. A post-life-test analysis was performed on two of the assemblies to evaluate the lubricant behavior and wear in the bearings.

Powers, Charles E.

Scanning For Hotspots In Lamp Filaments

Scanning photometer designed for use in investigation of failures of incandescent lamp filaments. Maps brightness as function of position along each filament to identify bright (hot) spots, occurring at notches and signifying incipient breaks or rewelds. Also used to measure nonuniformity in outputs of such linear devices as light-emitting diodes, and to measure diffraction patterns of lenses.

Powers, Charles E.

Long-term life testing of Geostationary Operational Environmental Satellite (GOES) encoder lamps

The aging characteristics and lifetimes of tungsten filament encoder lamps were determined as a function of operating voltage and filament material. For pure tungsten and thoria doped (1 pct.) filament lamps, crystal grain growth over the center portion of the filament leads to the ultimate failure of the lamp. The development of notches associated with this grain growth is the cause of lamp burn out. Eventually, one of the notches will 'etch' through the filament, causing it to fail open. For rhenium doped (3 pct.) filament lamps, distortion of the filament leads to the ultimate failure of the lamp. The lifetime of these lamps is about 1 year at an operating voltage of 5.0 volts. The pure tungsten filament lamps have the longest average lifetime, and the thoria doped filament lamps have the shortest at 5.0 volts. The lifetimes of these lamps is about 7 years at an operating voltage of 3.5 volts. Data suggest that the rhenium doped lamps will have the longest average lifetime at 3.5 volts, and the thoria doped will have the shortest. These lifetimes are comparable to the desired lifetimes of 7 years.

Powers, Charles E.

Stepping-Motion Motor-Control Subsystem For Testing Bearings

Control subsystem closed-loop angular-position-control system causing motor and bearing under test to undergo any of variety of continuous or stepping motions. Also used to test bearing-and-motor assemblies, motors, angular-position sensors including rotating shafts, and like. Monitoring subsystem gathers data used to evaluate performance of bearing or other article under test. Monitoring subsystem described in article, "Monitoring Subsystem For Testing Bearings" (GSC-13432).

Powers, Charles E.

Monitoring Subsystem For Testing Bearings

Electronic monitoring subsystem designed to be used in conjunction with controlling subsystem described in article, "Stepping-Motion Motor-Control Subsystem For Testing Bearings" (GSC-13418). Gathers data used to evaluate performance of bearing motor or other rotary mechanism being tested by subjecting it to stepping motions like those in its intended application. Data gathered at rate high enough to characterize dynamic properties of mechanism.

Powers, Charles E.

Measuring Thermal Diffusivity Of A High-Tc Superconductor

Technique for measuring thermal diffusivity of superconductor of high critical temperature based on Angstrom's temperature-wave method. Peltier junction generates temperature oscillations, which propagate with attenuation up specimen. Thermal diffusivity of specimen calculated from distance between thermocouples and amplitudes and phases of oscillatory components of thermocouple readings.

Powers, Charles E.

A technique to measure the thermal diffusivity of high Tc superconductors

High T(sub c) superconducting electrical current leads and ground straps will be used in cryogenic coolers in future NASA Goddard Space Flight Center missions. These superconducting samples are long, thin leads with a typical diameter of two millimeters. A longitudinal method is developed to measure the thermal diffusivity of candidate materials for this application. This technique uses a peltier junction to supply an oscillatory heat wave into one end of a sample and will use low mass thermocouples to follow the heat wave along the sample. The thermal diffusivity is calculated using both the exponential decay of the heat wave and the phase shift to the wave. Measurements are performed in a cryostat between 10 K and room temperature.

Powers, Charles E.

A technique to measure the thermal diffusivity of high T(sub c) superconductors

High T(sub c) superconducting electrical current leads and ground straps will be used in cryogenic coolers in future NASA Goddard Space Flight Center missions. These superconducting samples will be long, thin leads with a typical diameter of two millimeters. A longitudinal method is being developed to measure the thermal diffusivity of candidate materials for this application. This technique will use a peltier junction to supply an oscillatory heat wave into one end of a sample and will use low mass thermocouples to follow the heat wave along the sample. The thermal diffusivity will be calculated using both the exponential decay of the heat wave and the phase shift of the wave. Measurements will be done in a cryostat between 10 K and room temperature.

Powers, Charles E.

Spatial conductivity measurements on high T(sub c) superconducting films

High T(sub c) superconducting thin and thick films have potential applications in future NASA flight projects. In anticipation of film use, the Materials Branch is developing a nondestructive, non-contact method of measuring the spatial variation of conductivity across a film sample. This method uses a computer-controlled, X-Y positioning table to scan a conventional eddy current probe across the surface of a film. The induced changes in impedance caused by variations in film conductivity are recorded during the scanning process. Ultimately the two-dimensional data set is displayed using imaging equipment on a personal computer.

Vansant, J. Timothy