Mechanical properties of Rene-41 affected by rate of cooling after solution annealing
Investigation of Rene-41 cooling rate from 1975 to 1400 degrees F reveals that slow cooling improves high-temperature ductility and provides more uniform properties throughout a manifold. Ambient elongation and impact resistance are not significantly changed.