Search NASA⌕ Search

Engineering topics

Preissner, C

Publications and source records attributed to Preissner, C.

A high-fidelity harmonic drive model.

In this paper, a new model of the harmonic drive transmission is presented. The purpose of this work is to better understand the transmission hysteresis behavior while constructing a new type of comprehensive harmonic drive model. The four dominant aspects of harmonic drive behavior - nonlinear viscous friction, nonlinear stiffness, hysteresis, and kinematic error - are all included in the model. The harmonic drive is taken to be a black box, and a dynamometer is used to observe the input/output relations of the transmission. This phenomenological approach does not require any specific knowledge of the internal kinematics. In a novel application, the Maxwell resistive-capacitor hysteresis model is applied to the harmonic drive. In this model, sets of linear stiffness elements in series with Coulomb friction elements are arranged in parallel to capture the hysteresis behavior of the transmission. The causal hysteresis model is combined with nonlinear viscous friction and spectral kinematic error models to accurately represent the harmonic drive behavior. Empirical measurements are presented to quantify all four aspects of the transmission behavior. These measurements motivate the formulation of the complete model. Simulation results are then compared to additional measurements of the harmonic drive performance.

99 GENERAL AND MISCELLANEOUS↗

Management of metadata and automation for mail-in measurements with the APS 11-BM high throughput, high-resolution synchrotron powder diffractometer.

A high-resolution and high-throughput synchrotron powder diffractometer has been automated for use with samples that are mailed in by Advanced Photon Source users. Implementation of a relational database with web interfaces for both outside users and beamline staff, which is integrated into the facility-wide proposal and safety system, allows all aspects of beamline management to be integrated. This system permits users to request kits for mounting samples, to provide sample safety information, to obtain their collected data and to provide usage information upon project completion in a quick and simple manner. Beamline staff use a separate interface to note receipt of samples, schedule and collect diffraction data, post-process and quality-check data, and dispose of samples. The design of the software and database are discussed in detail.

43 PARTICLE ACCELERATORS↗

A twelve-analyzer detector system for high-resolution powder diffraction.

A dedicated high-resolution high-throughput X-ray powder diffraction beamline has been constructed at the Advanced Photon Source (APS). In order to achieve the goals of both high resolution and high throughput in a powder instrument, a multi-analyzer detector system is required. The design and performance of the 12-analyzer detector system installed on the powder diffractometer at the 11-BM beamline of APS are presented.

43 PARTICLE ACCELERATORS↗