Search NASA⌕ Search

Engineering topics

Prilliman, Matthew

Publications and source records attributed to Prilliman, Matthew.

Blind photovoltaic modeling intercomparison: A multidimensional data analysis and lessons learned

The Photovoltaic (PV) Performance Modeling Collaborative (PVPMC) organized a blind PV performance modeling intercomparison to allow PV modelers to blindly test their models and modeling ability against real system data. Measured weather and irradiance data were provided along with detailed descriptions of PV systems from two locations (Albuquerque, New Mexico, USA, and Roskilde, Denmark). Participants were asked to simulate the plane-of-array irradiance, module temperature, and DC power output from six systems and submit their results to Sandia for processing. The results showed overall median mean bias (i.e., the average error per participant) of 0.6% in annual irradiation and –3.3% in annual energy yield. While most PV performance modeling results seem to exhibit higher precision and accuracy as compared to an earlier blind PV modeling study in 2010, human errors, modeling skills, and derates were found to still cause significant errors in the estimates.

14 SOLAR ENERGY↗

International Photovoltaic Modeling Intercomparison [Slides]

Irradiance transposition models seem to perform well, except the Isotropic with -11.25 W/m 2 underestimation. Most temperature models could not capture behavior when ΔΤ between module and ambient is negative. Uncertainties due to derate factors: modelers overbudgeted resulting in significant power underestimation; maybe ~10% is appropriate for commercial systems but not lab-scale? Most software and models cluster together showing good reproducibility among participants. Modeler’s skills seem to be more important than the PV model itself (flat efficiency with irradiance, positive power temperature coefficients, etc.). Results and best practices will be communicated in a journal article.

14 SOLAR ENERGY↗

Uncertainty Quantification of Bifacial Performance Modeling: Preprint

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗

Improvement in PV Plant LCOE from Convection Heat Transfer Changes from Altered Plant Layout

Heat transfer modeling that accounts for how convective cooling changes with PV array layout has been found to improve system LCOE in certain climates conditions. Analysis of fixed tilt systems performed using the System Advisor Model reveals that reducing system ground coverage ratio from 0.46 to 0.35 can lead to as much as a 1.7% increase in module annual energy output in Phoenix. Depending on climate conditions, these energy increases due to changing convective cooling flow can lead to LCOE improvements for systems with increased row spacing despite the increased wiring and land costs associated with increased module row spacing. While the energy gain from decreasing system ground coverage ratio can be largely attributed to increased plane of array irradiance, the convection cooling considerations presented here can have a non-negligible impact on PV power plant energy output and economic viability depending on climate conditions and array spacing parameters.

heat transfer↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

bifacial↗

Marine Energy Performance Models

This webinar was presented on August 18, 2021 and provides an overview of SAM's marine wave and tidal energy models.

ENERGY PLANNING, POLICY, AND ECONOMY,TIDAL AND WAV↗

Transient Weighted Moving-Average Model of Photovoltaic Module Back-Surface Temperature

Accurate modeling of photovoltaic (PV) performance requires the precise calculation of module temperature. Currently, most temperature models rely on steady-state assumptions that do not account for the transient climatic conditions and thermal mass of the module. On the other hand, complex physics-based transient models are computationally expensive and difficult to parameterize. In order to address this, a new approach to transient thermal modeling was developed, in which the steady-state predictions from previous timesteps are weighted and averaged to accurately predict the module temperature at finer time scales. This model is informed by 3-D finite-element analyses, which are used to calculate the effect of wind speed and module unit mass on module temperature. The model, in application, serves as an added filter over existing steady-state models that smooths out erroneous values that are a result of intermittency in solar resource. Validation of this moving-average model has shown that it can improve the overall PV energy performance model accuracy by as much as 0.58% over steady-state models based on mean absolute error improvements and can significantly reduce the variability between the model predictions and measured temperature times series data.

14 SOLAR ENERGY↗