Search NASA⌕ Search

Engineering topics

Primera-Pedrozo, Oliva M.

Publications and source records attributed to Primera-Pedrozo, Oliva M..

Optical constants measurements of liquids for modeling aerosolized threats

Spectroscopic identification of aerosolized chemical threats is challenging due to the complex nature of the photon/particle interaction, as well as the diversity of possible particle sizes, morphologies, and compositions. Constructing a database of laboratory - measured transmittance spectra that covers each permutation is not practical. However, calculation of the spectra using the measured optical constants as a function of wavenumber, n(?) and k(?), for each of the liquids and/or solids composing the aerosol particles provides a viable alternative. These synthetic spectra (vis-à-vis laboratory-measured spectra) can be used to identify chemicals of interest and subtract out background interferents in field measurements. Using a well-established multiple pathlength approach, we measure the optical constants n/k for liquids that may be found as chemical species of interest or common background interferents aerosolized in plumes. These measurements are also used to generate several test case aerosol synthetic spectra.

Lockwood, Schuyler↗

Controlling the Fluctuating Tip-Enhanced Raman Spectra of Chloramben on Silver Nanocubes

Tip-enhanced Raman (TER) scattering from molecules residing at plasmonic junctions can be used to detect, identify, and image single molecules. This is most evident for flat molecules interrogated under extreme conditions of temperatures and pressure. It is also the case for (bio)molecular systems that feature preferred orientations/conformations under ambient laboratory conditions. More complex molecules that can adopt multiple conformations and/or that feature different protonation and/or charge states give rise to complex TER spectra. Here we illustrate how the latter can be controlled in the case of chloramben molecules coated onto plasmonic silver nanocubes. We show that characteristic molecular Raman spectra cannot be obtained when tunneling plasmons are operative, i.e., when the tip is in direct contact with the chemically functionalized plasmonic nanoparticles. We rationalize these observations and propose an approach to less invasive, and hence, more analytical TER spectral imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Handheld Raman Spectrometers: Assessment Report

In April 2022 the National Urban Security Technology Laboratory’s System Assessment and Validation for Emergency Responders program conducted an operational assessment of ten commercially available handheld Raman spectrometers. Additionally, prior to the operational assessment, the Pacific Northwest National Laboratory conducted laboratory testing of the devices, including scanning a number of samples in various containers. This report summarizes the results of the assessment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

Using synthetic infrared spectra derived from n/k optical constants for standoff detection of chemical deposits

We report results from a recent field experiment to test the validity of using physics-based synthetic infrared spectra to serve as endmembers in a spectral database targeted at chemical deposits. Specifically, the optical constants n and k, (the real and imaginary part of the refractive index) were used to first model infrared reflectance spectra for different thicknesses of chemical layers (e.g. acetaminophen, methylphosphonic acid – MPA, etc.) on various conducting and insulating substrates such as aluminum, wood, and glass. In the experimental portion of the research, thin films of the solid and liquid analytes were deposited onto such substrates to form micron-thick layers of the analytes at different thicknesses: Standoff data from an imaging instrument were then recorded and analyzed to not only identify the different analytes, but also quantify the layer/deposit thickness. To gauge success, the detection results using the synthetic data were compared to the results from hemispherical reflectance (HRF) spectra that were collected for the same sample planchets measured in the field via standoff methods. Preliminary results indicate good agreement between the synthetic reference data as compared to the lab-measured HRF data in terms of their ability to quantitatively reduce longwave infrared data. Specifically, modeled IR spectra for acetaminophen on an aluminum planchet at various thicknesses (1, 2, 5, 10, 15, and 20 µm) were synthesized and compared with standoff field reflectance data as well as HRF laboratory reflectance spectra for two samples: a 5.2 µm- and 12.8 µm-thick layer of acetaminophen on aluminum. Using a first-order approximation, analysis of the field data estimates the thicknesses of the samples to be 2 and 10 µm for the two samples, respectively, while the HRF laboratory data yields thickness estimates of between 5-10 µm and 10 µm, respectively. Both yield reasonable estimates, with the uncertainty most likely due to factors yet to be accounted for in the synthetic spectra such as light scattering.

complex index of refraction, optical constants, hy↗