Boiling-Water Reactor Testing Capability in the Advanced Test Reactor
I-Loop is an irradiation facility that is currently being installed at the Advanced Test Reactor. It is a two-loop test facility capable of performing Light Water Reactor (LWR) irradiations in prototypic coolant conditions. The two loops are being installed to be capable of both Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) pressure, temperature, and chemistry environments. Each loop is nominally dedicated as a BWR or PWR for simplicity of operations. In-reactor water loop testing that an I-Loop provides is key to the deployment of new accident tolerant fuel technologies and other advanced LWR fuel concepts. Currently, pressurized water loops are the only testing facilities available to test BWR fuel concepts. Their test environments are non-prototypic at higher pressure/temperature and at single-phase fluid flow conditions. This void in the LWR test bed capabilities is one that the I-Loop is uniquely situated to provide. This report discusses the mechanical design, thermal hydraulic calculations, and neutronic calculations of a proposed standard experiment of accident tolerant BWR fuel concepts. Mechanical design examines the geometry and features of the main components. Thermal hydraulic calculations examine the modeling and results of the two-phase flow options available. Lastly, neutronic calculations examine the Monte Carlo analysis of enrichment, heat rates, and flux spectrum.