Search NASASearch

Engineering topics

Prisk, G. K.

Publications and source records attributed to Prisk, G. K..

At least 19 records

Three-dimensional ballistocardiography and respiratory motion in sustained microgravity

BACKGROUND: We measured the three-dimensional ballistocardiogram (BCG) in a free-floating subject in sustained microgravity during spaceflight to test the usefulness of such measurements for future non-invasive monitoring of cardiac function, and to examine the effects of respiratory movement on the BCG in three axes. METHODS: Acceleration was measured using a three-axis accelerometer fastened to the lumbar region of the subject while simultaneous recordings of ECG, and respiratory motion via impedance plethysmography were also made. Data were recorded during a 146-s period of inactivity on the part of the subject during which time there was no contact with the spacecraft. RESULTS: Total body motion due to respiratory activity was consistent with that calculated from the known action of the diaphragm and conservation of momentum. The accelerations due to cardiac activity, ensemble averaged over the R-R interval, were greatest along the head-to-foot axis. Maximum amplitude of the HIJK complex of the BCG generated by ventricular ejection was greatest in the head to foot axis (approximately 70 x 10(-3) m x s(-2)), but there were also substantial accelerations along the dorsoventral axis of up to 43 10(-3) m x s(-2), that are not measured interrestrial two-dimensional studies. The amplitude of the BCG was strongly affected by lung volume, with accelerations being reduced 50 to 70% between end-inspiration and end-expiration. CONCLUSIONS: These data suggest a greatly reduced transmission of the cardiac motion to the body at end-expiration (FRC) than at higher lung volumes. The BCG might be further developed as a non-invasive means of monitoring parameters such as stroke volume in microgravity.

Flight Experiment

Sleep, performance, circadian rhythms, and light-dark cycles during two space shuttle flights

Sleep, circadian rhythm, and neurobehavioral performance measures were obtained in five astronauts before, during, and after 16-day or 10-day space missions. In space, scheduled rest-activity cycles were 20-35 min shorter than 24 h. Light-dark cycles were highly variable on the flight deck, and daytime illuminances in other compartments of the spacecraft were very low (5.0-79.4 lx). In space, the amplitude of the body temperature rhythm was reduced and the circadian rhythm of urinary cortisol appeared misaligned relative to the imposed non-24-h sleep-wake schedule. Neurobehavioral performance decrements were observed. Sleep duration, assessed by questionnaires and actigraphy, was only approximately 6.5 h/day. Subjective sleep quality diminished. Polysomnography revealed more wakefulness and less slow-wave sleep during the final third of sleep episodes. Administration of melatonin (0.3 mg) on alternate nights did not improve sleep. After return to earth, rapid eye movement (REM) sleep was markedly increased. Crewmembers on these flights experienced circadian rhythm disturbances, sleep loss, decrements in neurobehavioral performance, and postflight changes in REM sleep.

Non-NASA Center

Microgravity reduces sleep-disordered breathing in humans

To understand the factors that alter sleep quality in space, we studied the effect of spaceflight on sleep-disordered breathing. We analyzed 77 8-h, full polysomnographic recordings (PSGs) from five healthy subjects before spaceflight, on four occasions per subject during either a 16- or 9-d space shuttle mission and shortly after return to earth. Microgravity was associated with a 55% reduction in the apnea-hypopnea index (AHI), which decreased from a preflight value of 8.3 +/- 1.6 to 3.4 +/- 0.8 events/h inflight. This reduction in AHI was accompanied by a virtual elimination of snoring, which fell from 16.5 +/- 3.0% of total sleep time preflight to 0.7 +/- 0.5% inflight. Electroencephalogram (EEG) arousals also decreased in microgravity (by 19%), and this decrease was almost entirely a consequence of the reduction in respiratory-related arousals, which fell from 5.5 +/- 1.2 arousals/h preflight to 1.8 +/- 0.6 inflight. Postflight there was a return to near or slightly above preflight levels in these variables. We conclude that sleep quality during spaceflight is not degraded by sleep-disordered breathing. This is the first direct demonstration that gravity plays a dominant role in the generation of apneas, hypopneas, and snoring in healthy subjects.

short duration

Ventilation-perfusion matching in long-term microgravity

We studied the ventilation-perfusion matching pattern in normal gravity (1 G) and short- and long-duration microgravity (microG) using the cardiogenic oscillations in the sulfur hexaflouride (SF(6)) and CO(2) concentration signals during the phase III portion of vital capacity single-breath washout experiments. The signal power of the cardiogenic concentration variations was assessed by spectral analysis, and the phase angle between the oscillations of the two simultaneously expired gases was obtained through cross-correlation. For CO(2), a significant reduction of cardiogenic power was observed in microG, with respect to 1 G, but the reduction was smaller and more variable in the case of SF(6). A shift from an in-phase condition in 1 G to an out-of-phase condition was found for both short- and long-duration microG. We conclude that, although the distribution of ventilation and perfusion becomes more homogeneous in microG, significant inhomogeneities persist and that areas of high perfusion become associated with areas of relatively lower ventilation. In addition, these modifications seem to remain constant during long-term exposure to microG.

Mir Project

Dispersion of 0.5- to 2-micron aerosol in microG and hypergravity as a probe of convective inhomogeneity in the lung

We used aerosol boluses to study convective gas mixing in the lung of four healthy subjects on the ground (1 G) and during short periods of microgravity (microG) and hypergravity ( approximately 1. 6 G). Boluses of 0.5-, 1-, and 2-micron-diameter particles were inhaled at different points in an inspiration from residual volume to 1 liter above functional residual capacity. The volume of air inhaled after the bolus [the penetration volume (Vp)] ranged from 150 to 1,500 ml. Aerosol concentration and flow rate were continuously measured at the mouth. The dispersion, deposition, and position of the bolus in the expired gas were calculated from these data. For each particle size, both bolus dispersion and deposition increased with Vp and were gravity dependent, with the largest dispersion and deposition occurring for the largest G level. Whereas intrinsic particle motions (diffusion, sedimentation, inertia) did not influence dispersion at shallow depths, we found that sedimentation significantly affected dispersion in the distal part of the lung (Vp >500 ml). For 0.5-micron-diameter particles for which sedimentation velocity is low, the differences between dispersion in microG and 1 G likely reflect the differences in gravitational convective inhomogeneity of ventilation between microG and 1 G.

NASA Discipline Cardiopulmonary

A source of experimental underestimation of aerosol bolus deposition

We examined the measurement error in inhaled and exhaled aerosol concentration resulting from the bolus delivery system when small volumes of monodisperse aerosols are inspired to different lung depths. A laser photometer that illuminated approximately 75% of the breathing path cross section recorded low inhaled bolus half-widths (42 ml) and negative deposition values for shallow bolus inhalation when the inhalation path of a 60-ml aerosol was straight and unobstructed. We attributed these results to incomplete mixing of the inhaled aerosol bolus over the breathing path cross section, on the basis of simultaneous recordings of the photometer with a particle-counter sampling from either the center or the edge of the breathing path. Inserting a 90 degrees bend into the inhaled bolus path increased the photometer measurement of inhaled bolus half-width to 57 ml and yielded positive deposition values. Dispersion, which is predominantly affected by exhaled bolus half-width, was not significantly altered by the 90 degrees bend. We conclude that aerosol bolus-delivery systems should ensure adequate mixing of the inhaled bolus to avoid error in measurement of bolus deposition.

Non-NASA Center

Ambient Light Intensity, Actigraphy, Sleep and Respiration, Circadian Temperature and Melatonin Rhythms and Daytime Performance of Crew Members During Space Flight on STS-90 and STS-95 Missions

Sleep disruption and associated waking sleepiness and fatigue are common during space flight. A survey of 58 crew members from nine space shuttle missions revealed that most suffered from sleep disruption, and reportedly slept an average of only 6.1 hours per day of flight as compared to an average of 7.9 hours per day on the ground. Nineteen percent of crewmembers on single shift missions and 50 percent of the crewmembers in dual shift operations reported sleeping pill usage (benzodiazepines) during their missions. Benzodiazepines are effective as hypnotics, however, not without adverse side effects including carryover sedation and performance impairment, anterograde amnesia, and alterations in sleep EEG. Our preliminary ground-based data suggest that pre-sleep administration of 0.3 mg of the pineal hormone melatonin may have the acute hypnotic properties needed for treating the sleep disruption of space flight without producing the adverse side effects associated with benzodiazepines. We hypothesize that pre-sleep administration of melatonin will result in decreased sleep latency, reduced nocturnal sleep disruption, improved sleep efficiency, and enhanced next-day alertness and cognitive performance both in ground-based simulations and during the space shuttle missions. Specifically, we have carried out experiments in which: (1) ambient light intensity aboard the space shuttle is assessed during flight; (2) the impact of space flight on sleep (assessed polysomnographically and actigraphically), respiration during sleep, circadian temperature and melatonin rhythms, waking neurobehavioral alertness and performance is assessed in crew members of the Neurolab and STS-95 missions; (3) the effectiveness of melatonin as a hypnotic is assessed independently of its effects on the phase of the endogenous circadian pacemaker in ground-based studies, using a powerful experimental model of the dyssomnia of space flight; (4) the effectiveness of melatonin as a hypnotic is assessed during the STS-90 (Neurolab) and STS-95 missions in a double-blind placebo-controlled trial. In both flight-based experiments, the effects of melatonin on sleep stages and spectral composition of the EEG during sleep will be determined as well as its effects on daytime alertness and performance; (5) the impact of space flight on sleep and waking neurobehavioral alertness and performance in 30-45-year-old astronauts is compared with its impact in a 77-year-old astronaut. This case study is the first to assess the effects of space flight on an older individual. Because the investigators are still blind to the treatment in this double-blind, placebo-controlled trial, preliminary results will be presented independent of the drug condition.

Czeisler, Charles A.

Deposition and dispersion of 1-micrometer aerosol boluses in the human lung: effect of micro- and hypergravity

We performed bolus inhalations of 1-micrometer particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (microG) and in approximately 1.6 G. Boluses of approximately 70 ml were inhaled at different points in an inspiration from residual volume to 1 liter above functional residual capacity. The volume of air inhaled after the bolus [the penetration volume (Vp)] ranged from 200 to 1,500 ml. Aerosol concentration and flow rate were continuously measured at the mouth. The deposition, dispersion, and position of the bolus in the expired gas were calculated from these data. For Vp >/=400 ml, both deposition and dispersion increased with Vp and were strongly gravity dependent, with the greatest deposition and dispersion occurring for the largest G level. At Vp = 800 ml, deposition and dispersion increased from 33.9% and 319 ml in microG to 56.9% and 573 ml at approximately 1.6 G, respectively (P < 0.05). At each G level, the bolus was expired at a smaller volume than Vp, and this volume became smaller with increasing Vp. Although dispersion was lower in microG than in 1 G and approximately 1.6 G, it still increased steadily with increasing Vp, showing that nongravitational ventilatory inhomogeneity is partly responsible for dispersion in the human lung.

Parabolic Flight

Chest wall mechanics in sustained microgravity

We assessed the effects of sustained weightlessness on chest wall mechanics in five astronauts who were studied before, during, and after the 10-day Spacelab D-2 mission (n = 3) and the 180-day Euromir-95 mission (n = 2). We measured flow and pressure at the mouth and rib cage and abdominal volumes during resting breathing and during a relaxation maneuver from midinspiratory capacity to functional residual capacity. Microgravity produced marked and consistent changes (Delta) in the contribution of the abdomen to tidal volume [DeltaVab/(DeltaVab + DeltaVrc), where Vab is abdominal volume and Vrc is rib cage volume], which increased from 30.7 +/- 3. 5 (SE)% at 1 G head-to-foot acceleration to 58.3 +/- 5.7% at 0 G head-to-foot acceleration (P < 0.005). Values of DeltaVab/(DeltaVab + DeltaVrc) did not change significantly during the 180 days of the Euromir mission, but in the two subjects DeltaVab/(DeltaVab + DeltaVrc) was greater on postflight day 1 than on subsequent postflight days or preflight. In the two subjects who produced satisfactory relaxation maneuvers, the slope of the Konno-Mead plot decreased in microgravity; this decrease was entirely accounted for by an increase in abdominal compliance because rib cage compliance did not change. These alterations are similar to those previously reported during short periods of weightlessness inside aircrafts flying parabolic trajectories. They are also qualitatively similar to those observed on going from upright to supine posture; however, in contrast to microgravity, such postural change reduces rib cage compliance.

manned

Hypercapnic ventilatory response in humans before, during, and after 23 days of low level CO2 exposure

Alterations in ventilation and the chemoreceptor response to CO2 during 23 d of 1.2% inspired CO2 were studied in four male subjects. Resting ventilation (VE), tidal volume (VT), respiratory frequency (fR), inspired and end tidal O2 and CO2 and the hypercapnic ventilatory response (HCVR) measured by CO2 rebreathing were measured once before entering the chamber, on days 2, 5, 11, and 22 of CO2 exposure, and one day after. Resting VE slightly increased (5%) on day 2 of exposure and significantly increased (22%) by day 5 followed by a progressive decrease to pre-chamber levels by day 22 and on the first day of recovery. Tidal volume and fR were not statistically different. During the exposure PetCO2 was significantly elevated with day 2 having the largest increase (19.6%). PetCO2 returned to normal within 24 h post exposure. The HCVR was characterized by the slope (SHCVR), intercept at zero ventilation (B), and the ventilation at a PCO2 = 60 mmHg (VE60). The SHCVR decreased (14%) on day 2, but was not significant; the SHCVR on the other exposure days were also not different. The SHCVR on the first recovery day significantly increased (37%). The HCVR B was shifted to the right on day 2 by 5.2 mmHg, then progressively returned to the pre-exposure position. On recovery the B significantly shifted 6.9 mmHg to the right of pre-exposure B. The VE60 decreased by approximately 32% and 16% on day 2 and 5, respectively, then returned within pre-exposure range for the remainder of the exposure and during recovery. During the early phase and one day after the exposure the HCVR was right shifted. One day after exposure chemoreceptor sensitivity to elevated CO2 was increased but, the B was right shifted resulting in a reduced HCVR below PCO2 of 60 mmHg and a greater HCVR above 60 mmHg.

NASA Discipline Cardiopulmonary

Cardiogenic oscillation phase relationships during single-breath tests performed in microgravity

We studied the phase relationships of the cardiogenic oscillations in the phase III portion of single-breath washouts (SBW) in normal gravity (1 G) and in sustained microgravity (microG). The SBW consisted of a vital capacity inspiration of 5% He-1.25% sulfurhexafluoride-balance O2, preceded at residual volume by a 150-ml Ar bolus. Pairs of gas signals, all of which still showed cardiogenic oscillations, were cross-correlated, and their phase difference was expressed as an angle. Phase relationships between inspired gases (e.g., He) and resident gas (n2) showed no change from 1 G (211 +/- 9 degrees) to microG (163 +/- 7 degrees). Ar bolus and He were unaltered between 1 G (173 +/- 15 degrees) and microG (211 +/- 25 degrees), showing that airway closure in microG remains in regions of high specific ventilation and suggesting that airway closure results from lung regions reaching low regional volume near residual volume. In contrast, CO2 reversed phase with He between 1 G (332 +/- 6 degrees) and microG (263 +/- 27 degrees), strongly suggesting that, in microG, areas of high ventilation are associated with high ventilation-perfusion ratio (VA/Q). This widening of the range of VA/Q in microG may explain previous measurements (G.K. Prisk, A.R. Elliott, H.J.B. Guy, J.M. Kosonen, and J.B. West J. Appl. Physiol. 79: 1290-1298, 1995) of an overall unaltered range of VA/Q in microG, despite more homogeneous distributions of both ventilation and perfusion.

Non-NASA Center

Sleep and respiration in microgravity

Sleep studies conducted during the STS-90 Neurolab mission are explored. The relationship between sleep, melatonin, and circadian phase is reviewed. The study contained both sleep and awake components. The objectives of the sleep component were to test five hypotheses: that circadian rhythms of core body temperature and urinary melatonin are synchronized to required sleep-wake schedules, that spaceflight results in substantial disruption of sleep, that the pattern of chest and abdominal wall motion alters during the different sleep stages in microgravity, that arterial oxygen saturation is reduced during some stages of sleep in microgravity, and that pre-sleep administration of melatonin during microgravity results in improved sleep quality. The awake component tested three hypotheses: that ventilatory response to carbon dioxide is increased during exposure to microgravity and that this exacerbates sleep disruption, that ventilatory response to hypoxia is increased by exposure to microgravity, and that the improved sleep resulting from the pre-sleep administration of melatonin enhances next day cognition when compared to placebo.

Non-NASA Center

Multiple-breath washin of helium and sulfur hexafluoride in sustained microgravity

We performed multiple-breath washouts of N2 and simultaneous washins of He and SF6 with fixed tidal volume (approximately 1,250 ml) and preinspiratory lung volume (approximately the subject's functional residual capacity in the standing position) in four normal subjects (mean age 40 yr) standing and supine in normal gravity (1 G) and during exposure to sustained microgravity (microG). The primary objective was to examine the influence of diffusive processes on the residual, nongravitational ventilatory inhomogeneity in the lung in microG. We calculated several indexes of convective ventilatory inhomogeneity from each gas species. A normal degree of ventilatory inhomogeneity was seen in the standing position at 1 G that was largely unaltered in the supine position. When we compared the standing position in 1 G with microG, there were reductions in phase III slope in all gases, consistent with a reduction in convection-dependent inhomogeneity in the lung in microG, although considerable convective inhomogeneity persisted in microG. The reductions in the indexes of convection-dependent inhomogeneity were greater for He than for SF6, suggesting that the distances between remaining nonuniformly ventilated compartments in microG were short enough for diffusion of He to be an effective mechanism to reduce gas concentration differences between them.

NASA Discipline Cardiopulmonary

Effect of microgravity and hypergravity on deposition of 0.5- to 3-micron-diameter aerosol in the human lung

We measured intrapulmonary deposition of 0. 5-, 1-, 2-, and 3-micron-diameter particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (microG) and at approximately 1.6 G. Subjects breathed aerosols at a constant flow rate (0.4 l/s) and tidal volume (0.75 liter). At 1 G and approximately 1.6 G, deposition increased with increasing particle size. In microG, differences in deposition as a function of particle size were almost abolished. Deposition was a nearly linear function of the G level for 2- and 3-micron-diameter particles, whereas for 0.5- and 1.0-micron-diameter particles, deposition increased less between microG and 1 G than between 1 G and approximately 1.6 G. Comparison with numerical predictions showed good agreement for 1-, 2-, and 3-micron-diameter particles at 1 and approximately 1.6 G, whereas the model consistently underestimated deposition in microG. The higher deposition observed in microG compared with model predictions might be explained by a larger deposition by diffusion because of a higher alveolar concentration of aerosol in microG and to the nonreversibility of the flow, causing additional mixing of the aerosols.

Flight Experiment

Pulmonary tissue volume, cardiac output, and diffusing capacity in sustained microgravity

In microgravity (microG) humans have marked changes in body fluids, with a combination of an overall fluid loss and a redistribution of fluids in the cranial direction. We investigated whether interstitial pulmonary edema develops as a result of a headward fluid shift or whether pulmonary tissue fluid volume is reduced as a result of the overall loss of body fluid. We measured pulmonary tissue volume (Vti), capillary blood flow, and diffusing capacity in four subjects before, during, and after 10 days of exposure to microG during spaceflight. Measurements were made by rebreathing a gas mixture containing small amounts of acetylene, carbon monoxide, and argon. Measurements made early in flight in two subjects showed no change in Vti despite large increases in stroke volume (40%) and diffusing capacity (13%) consistent with increased pulmonary capillary blood volume. Late in-flight measurements in four subjects showed a 25% reduction in Vti compared with preflight controls (P < 0.001). There was a concomittant reduction in stroke volume, to the extent that it was no longer significantly different from preflight control. Diffusing capacity remained elevated (11%; P < 0.05) late in flight. These findings suggest that, despite increased pulmonary perfusion and pulmonary capillary blood volume, interstitial pulmonary edema does not result from exposure to microG.

Clinical Trial

Ventilation distribution and chest wall mechanics in microgravity

The effect of gravity on lung ventilation distribution and the mechanisms of the chest wall were investigated. The following tests were performed with the respiratory monitoring system of the Anthorack, flown onboard Spacelab D2 mission: single breath washout (SBW), multiple breath washout (MBW) and argon rebreathing (ARB). In order to study chest wall mechanisms in microgravity, a respiratory inductive plethysmograph was used. The SBW tests did not reach statistical significance, while the ARB tests showed that gravity independent inhomogeneity of specific ventilation is larger than gravity dependent inhomogeneity. In which concerns the chest wall mechanisms, the analysis on the four astronauts during the normal respirations of the relaxation maneuver showed a 40 percent increase on the abdominal contribution to respiration.

Paiva, M.

Pulmonary function in space

The lung is exquisitely sensitive to gravity, and so it is of interest to know how its function is altered in the weightlessness of space. Studies on National Aeronautics and Space Administration (NASA) Spacelabs during the last 4 years have provided the first comprehensive data on the extensive changes in pulmonary function that occur in sustained microgravity. Measurements of pulmonary function were made on astronauts during space shuttle flights lasting 9 and 14 days and were compared with extensive ground-based measurements before and after the flights. Compared with preflight measurements, cardiac output increased by 18% during space flight, and stroke volume increased by 46%. Paradoxically, the increase in stroke volume occurred in the face of reductions in central venous pressure and circulating blood volume. Diffusing capacity increased by 28%, and the increase in the diffusing capacity of the alveolar membrane was unexpectedly large based on findings in normal gravity. The change in the alveolar membrane may reflect the effects of uniform filling of the pulmonary capillary bed. Distributions of blood flow and ventilation throughout the lung were more uniform in space, but some unevenness remained, indicating the importance of nongravitational factors. A surprising finding was that airway closing volume was approximately the same in microgravity and in normal gravity, emphasizing the importance of mechanical properties of the airways in determining whether they close. Residual volume was unexpectedly reduced by 18% in microgravity, possibly because of uniform alveolar expansion. The findings indicate that pulmonary function is greatly altered in microgravity, but none of the changes observed so far will apparently limit long-term space flight. In addition, the data help to clarify how gravity affects pulmonary function in the normal gravity environment on Earth.

short duration

Cardiopulmonary adaptation to weightlessness

The lung is profoundly affected by gravity. The absence of gravity (microgravity) removes the mechanical stresses acting on the lung paranchyma itself, resulting in a reduction in the deformation of the lung due to its own weight, and consequently altering the distribution of fresh gas ventilation within the lung. There are also changes in the mechanical forces acting on the rib cage and abdomen, which alters the manner in which the lung expands. The other way in which microgravity affects the lung is through the removal of the gravitationally induced hydrostatic gradients in vascular pressures, both within the lung itself, and within the entire body. The abolition of a pressure gradient within the pulmonary circulation would be expected to result in a greater degree of uniformity of blood flow within the lung, while the removal of the hydrostatic gradient within the body should result in an increase in venous return and intra-thoracic blood volume, with attendant changes in cardiac output, stroke volume, and pulmonary diffusing capacity. During the 9 day flight of Spacelab Life Sciences-1 (SLS-1) we collected pulmonary function test data on the crew of the mission. We compared the results obtained in microgravity with those obtained on the ground in both the standing and supine positions, preflight and in the week immediately following the mission. A number of the tests in the package were aimed at studying the anticipated changes in cardiopulmonary function, and we report those in this communication.

short duration