The analysis of Gemini 7 EEG data by three different computer oriented methods
The problem in assessment of electroencephalograms has been the subject element in visual evaluations of such records as well as the need for extensive training (2 or 3 years) before suitable candidate is capable to perform this task. There have been variety of computer type analyses of EEG during the past ten years or more, and we are still searching for a reliable, inexpensive, online data processing procedure for this task. We are aware our Soviet colleagues are routinely using computer assessment of EEGs, using relatively inexpensive hardware. In our report we endeavor to show how four different assessment procedures (visual assessment, zero crossing technique, smoothing and peak counting technique, and Weibull Statistic) may be utilized, and indicate the advantages and disadvantages peculiar to each. We wish to point out that in the Gemini 7 EEG analog records supplied to the Henry Ford Hospital, Channel II (mid-line central to mid-line occipital electrodes) could not be assessed reliably after approximately 26 hours of flight. Channel I (left central to left occipital electrodes) provided the more assessable EEG up to approximately 54 hours of flight. These channels were compared during the first 26 hours of flight, and no significant difference was found by our various assessment procedures. We, therefore, have limited this report to the findings on the analyses of Channel I during its approximate 54 hours of flight.