Evaluation of Advanced Phased-Array Techniques: Interim Results [Slides]

Report: “Evaluation of Advanced Phased-Array Techniques: Interim Results”, August 2023 ML23216A009, PNNL-34622 Results showed that detection rate drops as microstructures/materials become more complex Standard PA had the highest detection rates overall Detection rates in the CASS-CASS mockups were lowest overall FMC had the most accurate length sizing in the fine-grained WSS mockups. All methods struggled with length sizing in coarse-grained mockups SNR vs method depended on the specimen type SNR was consistently high with standard PA SNR was consistently the lowest with PWI FMC performed best on fine-grained WSS A lack of data received from some Round Robin participants resulted in low statistics for many of the analyses.

42 ENGINEERING↗

Evaluation of Advanced Phased-Array Techniques: Interim Results [Slides]

Report: “Evaluation of Advanced Phased-Array Techniques: Interim Results”, August 2023 ML23216A009, PNNL-34622 Results showed that detection rate drops as microstructures/materials become more complex Standard PA had the highest detection rates overall Detection rates in the CASS-CASS mockups were lowest overall FMC had the most accurate length sizing in the fine-grained WSS mockups. All methods struggled with length sizing in coarse-grained mockups SNR vs method depended on the specimen type SNR was consistently high with standard PA SNR was consistently the lowest with PWI FMC performed best on fine-grained WSS A lack of data received from some Round Robin participants resulted in low statistics for many of the analyses.

42 ENGINEERING↗

Heat exchanger assemblies having embedded sensors

Heat exchanger assemblies are provided that can include: a heat exchanger housing; at least one primary conduit operably coupled to the heat exchanger housing and configured to convey a primary heat exchange fluid; at least one secondary conduit operably coupled to the heat exchanger housing and configured to convey a secondary heat exchange fluid; at least one thermal interface between the primary and secondary fluids; and at least one sensor operably engaged with the thermal interface. Heat exchanger assemblies including molten salt, liquid metal, or water/steam as part of the heat exchange fluids of the heat exchanger assembly are provided. The heat exchanger assemblies can include: at least one thermal interface between primary and secondary heat exchange fluids of the heat exchanger assembly; and a sensor operably engaged with the at least one interface.

Glass, III, Samuel W.↗