Search NASA⌕ Search

Engineering topics

Qian, D.

Publications and source records attributed to Qian, D..

Magnetic properties of the low-dimensional Ba M 2 Si 2 O 7 system ( M = Cu , Co , Mn )

Here, we explored the magnetic properties of the low-dimensional Ba M 2 Si 2 O 7 (M = Cu, Co, and Mn) system using both experimental measurements and theoretical calculations. Magnetization, specific heat, and single crystal neutron diffraction measurements have been performed on single crystal Ba M 2 Si 2 O 7 . The spin structure was determined and a magnetic phase diagram with applied field along the b axis was constructed, which contains a spin flop transition around 6 T. Magnetization and specific heat measurements confirmed the presence of weak ferromagnetism in Ba M 2 Si 2 O 7 . Furthermore, we performed local-spin density approximation with on-site Coulomb energy (LSDA+U) calculations for the Ba M 2 Si 2 O 7 (M = Cu, Co, and Mn) system. Due to the first-principles calculations, the origin of the magnetic differences of the three materials is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser pyrolysis fabrication of ferromagnetic gamma'-Fe4N and FeC nanoparticles

Using the laser pyrolysis method, single phase gamma'-Fe4N nanoparticles were prepared by a two step method involving preparation of nanoscale iron oxide and a subsequent gas-solid nitridation reaction. Single phase Fe3C and Fe7C3 could be prepared by laser pyrolysis from Fe(CO)5 and 3C2H4 directly. Characterization techniques such as XRD, TEM and vibrating sample magnetometer were used to measure phase structure, particle size and magnetic properties of these nanoscale nitride and carbide particles. c2000 American Journal of Physics.

NASA Discipline Life Sciences Technologies↗

Magnetoelastic sensors in combination with nanometer-scale honeycombed thin film ceramic TiO2 for remote query measurement of humidity

Ribbonlike magnetoelastic sensors can be considered the magnetic analog of an acoustic bell; in response to an externally applied magnetic field impulse the sensors emit magnetic flux with a characteristic resonant frequency. The magnetic flux can be detected external to the test area using a pick-up coil, enabling query remote monitoring of the sensor. The characteristic resonant frequency of a magnetoelastic sensor changes in response to mass loads. [L.D. Landau and E. M. Lifshitz, Theory of Elasticity, 3rd ed. (Pergamon, New York, 1986). p. 100].Therefore, remote query chemical sensors can be fabricated by combining the magnetoelastic sensors with a mass changing, chemically responsive layer. In this work magnetoelastic sensors are coated with humidity-sensitive thin films of ceramic, nanodimensionally porous TiO2 to make remote query humidity sensors. c2000 American Institute of Physics.

NASA Discipline Life Sciences Technologies↗