Search NASA⌕ Search

Engineering topics

Qiao, Zhi

Publications and source records attributed to Qiao, Zhi.

X-ray optics for the cavity-based X-ray free-electron laser

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

47 OTHER INSTRUMENTATION↗

At-wavelength characterization of X-ray wavefronts in Bragg diffraction from crystals

The advent of next-generation synchrotron radiation sources and X-ray free-electron lasers calls for high-quality Bragg-diffraction crystal optics to preserve the X-ray beam coherence and wavefront. This requirement brings new challenges in characterizing crystals in Bragg diffraction in terms of Bragg-plane height errors and wavefront phase distortions. Here, a quantitative methodology to characterize crystal optics using a state-of-the-art at-wavelength wavefront sensing technique and statistical analysis is proposed. The method was tested at the 1-BM-B optics testing beamline at the Advanced Photon Source for measuring silicon and diamond crystals in a self-referencing single-crystal mode and an absolute double-crystal mode. The phase error sensitivity of the technique is demonstrated to be at the λ/100 level required by most applications, such as the characterization of diamond crystals for cavity-based X-ray free-electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Regulating Catalytic Properties and Thermal Stability of Pt and PtCo Intermetallic Fuel-Cell Catalysts via Strong Coupling Effects between Single-Metal Site-Rich Carbon and Pt

Developing low platinum-group-metal (PGM) catalysts for the oxygen reduction reaction (ORR) in proton-exchange membrane fuel cells (PEMFCs) for heavy-duty vehicles (HDVs) remains a great challenge due to the highly demanded power density and long-term durability. Here, this work explores the possible synergistic effect between single Mn site-rich carbon (Mn SA -NC) and Pt nanoparticles, aiming to improve intrinsic activity and stability of PGM catalysts. Density functional theory (DFT) calculations predicted a strong coupling effect between Pt and MnN 4 sites in the carbon support, strengthening their interactions to immobilize Pt nanoparticles during the ORR. The adjacent MnN 4 sites weaken oxygen adsorption at Pt to enhance intrinsic activity. Well-dispersed Pt (2.1 nm) and ordered L1 2 -Pt 3 Co nanoparticles (3.3 nm) were retained on the Mn SA -NC support after indispensable high-temperature annealing up to 800 °C, suggesting enhanced thermal stability. Both PGM catalysts were thoroughly studied in membrane electrode assemblies (MEAs), showing compelling performance and durability. The Pt@Mn SA -NC catalyst achieved a mass activity (MA) of 0.63 A mg Pt –1 at 0.9 V iR-free and maintained 78% of its initial performance after a 30,000-cycle accelerated stress test (AST). The L1 2 -Pt 3 Co@Mn SA -NC catalyst accomplished a much higher MA of 0.91 A mg Pt –1 and a current density of 1.63 A cm –2 at 0.7 V under traditional light-duty vehicle (LDV) H 2 –air conditions (150 kPa abs and 0.10 mg Pt cm –2 ). Furthermore, the same catalyst in an HDV MEA (250 kPa abs and 0.20 mg Pt cm –2 ) delivered 1.75 A cm –2 at 0.7 V, only losing 18% performance after 90,000 cycles of the AST, demonstrating great potential to meet the DOE targets.

25 ENERGY STORAGE↗

Coded-mask-based X-ray phase-contrast and dark-field imaging

Phase contrast and dark-field X-ray imaging enable imaging of objects that absorb or reflect very little X-ray light. Disclosed is a method and systems for performing coded-mask-based multi-contrast imaging (CMMI). The method includes providing radiation to a coded mask that has a known phase and absorption profile according to a pre-determined pattern. The radiation is then impingent upon a sample, and the radiation is detected to perform phase-reconstruction and image processing. The method and associated systems allow for the use of maximum-likelihood and machine learning methods for reconstruction images of the sample from the detected radiation.

Shi, Xianbo↗

Real-time machine-learning-driven control system of a deformable mirror for achieving aberration-free X-ray wavefronts

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror’s response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

47 OTHER INSTRUMENTATION↗