Search NASA⌕ Search

Engineering topics

Qu, Shaoyang

Publications and source records attributed to Qu, Shaoyang.

An electrified boom actuation system with energy regeneration capability driven by a novel electro-hydraulic unit

This paper presents a novel electrified solution for linear actuation systems, which has undergone a successful in-vehicle demonstration, marking a significant advancement in this field. Aligned with the growing trend towards electrification, this solution holds promise for a wide range of off-road applications. The showcased electrohydraulic actuation architecture enables efficient four-quadrant operation and incorporates energy recovery capabilities. At the core of the system lies a distinctive electro-hydraulic unit, integrating a fixed hydraulic pump and a variable-speed electric motor into a compact and powerful entity. A specialized hydraulic system is designed to efficiently transform electrical energy from the electro-hydraulic unit into boom cylinder actuation. The sizing of the system is determined by the boom operation of a commercial compact loader. The maximum power output of the electro-hydraulic system is approximately 15 kW. The components of the proposed system are integrated into the reference vehicle, and comprehensive performance tests are conducted. The results of the tests performed on the vehicle with the boom lifting and lowering cycle indicate an overall system efficiency of 60%. The electrified solution consumes only about one-third of the energy used by the conventional boom actuation system on the reference machine, while exhibiting energy savings exceeding 75% during specific work phases. The energy savings come mainly from energy regeneration and minimal loss from throttling through the specialized hydraulic circuit design. Finally, the successful demonstration on the reference vehicle underscores the practicality and effectiveness of the proposed electrified solution in current mobile hydraulic applications

42 ENGINEERING↗

Experimental Verification of An Electro-Hydraulic Actuation System Driven by An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and a novel-designed electro-hydraulic unit (EHU) consisting of a fixed-displacement hydraulic gear machine and a variable-speed electric machine. The novel EHU design integrates an electric machine and a hydraulic machine in a single housing, targeting optimal compactness, power density, and component reduction. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. Here, the efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The efficiency of the EHA system based on the measurements on the test rig can reach 54% with up to 20 kN load and 6 kW power level. Furthermore, the EHU is implemented on the reference machine to drive the boom function. Preliminary results on the performance of the EHU show an efficiency of up to 68% under different loading conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pressure feedback control of electro-hydraulic actuators using fixed displacement hydraulic machines

This paper presents the development of a control strategy for Electro-Hydraulic Actuator (EHA) systems based on fixed displacement hydraulic machines. Although some previous studies on EHAs show benefits in terms of energy efficiency and regeneration capability compared to conventional hydraulic systems, few studies focus on the dynamic performance of EHAs. Unlike traditional valve-controlled systems, an EHA based on a fixed displacement pump typically relies on variation of the electric motor shaft speed to control the actuator velocity. This study shows that pressure feedback can be used to control the speed of the electric machine, thus achieving the required actuator/machine dynamic response. A simulation model is developed by including the EM, the hydraulic system, and the actuation system, which can give a realistic prediction of the EHA performance for a typical duty cycle. An open-circuit EHA previously proposed by the authors is used to validate the control strategy, and the simulation results show superior dynamic performance, exhibiting a reduction in response time and oscillatory behavior, compared to a feedforward EHA controller. Following the method presented in this study, it is possible to design a controller with a pressure feedback strategy for EHA systems with different size and actuation requirements

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Verification of An Open-Circuit Electro-Hydraulic Actuator System with An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and two novel-designed electro-hydraulic units (EHU) consisting of a fixed-displacement hydraulic pump and a variable-speed electric motor. Both the novel EHU designs integrate an electric machine and a hydraulic machine in a single unit, featuring compactness and power density. However, they differ for salient aspects such as power and electric machine cooling system. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. The efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The measured efficiency of the system can reach 54% with up to 20kN load and 6kW power level.

42 ENGINEERING↗

A Cost-Effective Electro-Hydraulic Actuator Solution with Open Circuit Architecture

With the recent electrification trend in the fluid power area, more research has been incentivized to propose cost-effective and energy-efficient solutions for hydraulic systems. Hence, electro-hydraulic actuator (EHA) architectures receive increasing attention. The paper proposes a novel open-circuit EHA architecture, with the goal to obtain a cost-effective solution for mobile applications while maximizing the overall system efficiency. The proposed EHA is capable of meeting or exceeding traditional off-road machine performance, therefore enabling further electrification of off-road machines. Four-quadrant functionality, covering the full speed range, is achieved by a combination of a variable electro-hydraulic drive and valves with different functions. Focusing on the steady-state performance, the functionality is validated by numerical as well as experimental methods. A simulation model based on the Amesim environment and a dedicated test setup was developed to verify the performance. Furthermore, the good match between simulation and experimental results confirms the potential of the formulation approach of the proposed EHA for applications with different duty cycles and power levels.

4-quadrant functionality↗

DEVELOPMENT OF A LUMPED-PARAMETER THERMAL MODEL FOR ELECTRO-HYDRAULIC ACTUATORS

This paper describes a thermal-hydraulic modeling method of a closed-circuit electro-hydraulic actuator (EHA). Despite the high energy efficiency of EHAs, it is always important to assess their cooling requirements, to guarantee that the operating temperature remains within an acceptable range. The method proposed in this paper is based on a lumped parameter approach and simplifies some of the complex heat transfer processes by introducing empirical correction factors. The model is validated by means of temperature measurements on an EHA architecture developed by the author. The good match between the simulation results and experiments confirms the capability of the proposed methodology to predict the temperature performance of the reference EHA under different drive cycles. The paper presents a detailed analysis of the power losses and passive heat dissipation for the reference system. Based on this analysis, the cooling requirements of the EHA are studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A High-Efficient Solution for Electro-Hydraulic Actuators with Energy Regeneration Capability

This paper proposes a cost-effective, robustly practical solution for a high-efficient electro-hydraulic actuator (EHA) for linear drives. The solution addresses the challenges of high costs and limited efficiency that limit the application of EHA for the electrification of many off-road vehicles. Based on a variable-speed electric motor and a low-cost technology for a fixed-displacement pump, the proposed solution is suitable for a compact implementation and it is capable of energy regeneration under overrunning load conditions. Two different architectures—an open circuit and a closed circuit one—are considered to determine the most practical and efficient configuration as well as the control features. Both architectures minimize throttling losses associated with the conventional regulation of hydraulic actuators. Actuator velocities below the minimum and beyond the maximum allowable pump flow rate are achieved in both architectures using a proportional valve that bypasses the pump flow. The paper describes the design methodology as well as the simulation and experimental activities performed to verify the control strategies as well as energy efficiency. Considering an EHA system of about 20 kW, a complete efficiency map of the system is determined for all the possible four quadrants of operation thus including both resistive and overrunning loads, where energy recuperation is implemented. Simulation and experimental results show that the energy efficiency of the hydraulic systems can reach 84.7% in resistive phases. In assistive phases, the hydraulic system can recover up to 81.8% of the actuator energy. Here, the comparison between open-circuit and closed-circuit structures shows the advantages of the former in terms of energy efficiency. The proposed solution is suitable for electrified hydraulic actuation systems, in both industrial and mobile applications. With the advantages of the low cost of the hydraulic unit and high energy efficiency, it is particularly suitable for mobile applications such as construction machines, that are recently experiencing a significant electrification trend.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Formulation, Design and Experimental Verification of an Open Circuit Electro-Hydraulic Actuator

With the recent electrification trend in the fluid power area, more research has been incentivized to the proposal of cost-effective and energy-efficient solutions for hydraulic systems. Hence, electro-hydraulic actuator (EHA) architectures receive increasing attention. The paper proposes a novel open-circuit EHA architecture, with the goal to obtain a cost-effective mobile solution while maximizing the overall system efficiency. The proposed EHA is capable of meeting or exceeding traditional off-road machine performance, therefore enabling further electrification of off-road machines. Four-quadrant functionality, covering the full speed range, is achieved by a combination of a variable electro-hydraulic drive and valves with different functions and is validated by numerical as well as experimental methods. Here, a simulation model based on the Amesim environment and a dedicated test setup was developed to verify the performance. The good match between simulation and experimental results confirms the potential of the formulation approach of the proposed EHA for applications with different duty cycles and power levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗