Search NASA⌕ Search

Engineering topics

Qu, Zhihua

Publications and source records attributed to Qu, Zhihua.

At least 19 records

Experiences and Lessons from Field Demonstration of Grid-forming Inverter in An AC Microgrid

The validation of GFM control strategies through simulation and hardware demonstration is important before their large-scale deployments in the real grid. Considering the importance of testing and validation, several works have explored the GFM inverter’s capability to blackstart a microgrid, synchronize and share loads, and interact with various types of generation sources and loads present in the grid. Herein, this paper complements the existing works by presenting the results and analysis of a field demonstration in an actual AC microgrid. The capability of a three-level neutral point clamped (NPC) GFM inverter equipped with a recursive feedback type of non-linear device level control to operate with PV source on its DC input and off-the-shelf PVGFL inverters and EV chargers of different kinds on the AC side is explored. The analysis and conclusions drawn would inform the readers to make better decisions during the field demonstration process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Consensus State Observer for Nonlinear Systems and Against Attacks

Herein, we investigate the design of a resilient consensus observer that yields correct and continuous state estimates of a nonlinear control system whose state observations are subject to attacks. The observations are assumed to be obtained from multiple sensors and/or communication channels employed to provide redundancy. It is shown that, in an attack-free setting, individual globally convergent observers can be designed for each sensor/channel using the corresponding state-dependent Jacobian system. To counter attacks, a resilient consensus observer is then designed by merging the observers estimates to produce a smooth consensus estimate. Resilient convergence of the consensus estimate to the true state is ensured under the condition that the sparsity of the attacks being less than a half of the number of redundant channels. As an illustrative example, the proposed scheme is successfully applied to the chaotic circuit synchronization problem in which their synchronization has been attacked.

97 MATHEMATICS AND COMPUTING↗

Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

Implementing a Hardware Testbed Using 3-Level ANPC Software Defined Inverters for Fault Analysis of a Transmission Network

In this paper, we propose the implementation of a hardware testbed using 3-level active neutral point clamped (ANPC) software-defined inverters for fault analysis. A test case transmission network equipped with two grid forming (GFM) inverters and four resistive loads is considered in this research. Firstly, grid forming control laws including PI feedback control and droop control are implemented to operate the inverters in parallel. Then, we implement a fault ride-through (FRT) logic and perform a simulation of the test system by applying a three-phase fault. Simulation results show the effectiveness of the fault recovery algorithm upon clearance of the fault. Finally, a 3-level ANPC software-defined inverter is programmed with required control laws and characterized through various lab experiments.

3-level ANPC inverter↗

Resilient Design of Continuous-time Distributed Optimization Algorithm in the Presence of Cyber-attacks

This paper presents a continuous-time resilient distributed optimization algorithm based on competitive interaction design method on connected graphs in the presence of adversaries. Here, the competitive interaction method allows us to design a network that protects the multi-agent systems from adversaries without requiring high network connectivity. In addition, the proposed algorithm does not require the global information about the number of adversaries. First, we show that the proposed distributed algorithm solves the resilient distributed optimization problem with no attack on the communication links. Second, we show that the proposed continuous-time distributed optimization algorithm on connected graphs converges to the small neighborhood of the optimal solution in the presence of cyber-attacks onto the communication channel. Simulations are presented to illustrate our theoretical results.

97 MATHEMATICS AND COMPUTING↗

Oscillatory Power Control and Consensus in Unbalanced Networks Using Grid Forming Inverters

In this paper, a state-space nonlinear control previously designed for balanced operation of grid-forming (GFM) inverters is extended to unbalanced operations. Unbalanced voltages and currents are analyzed, and their time-varying direct, quadrature, and zero components are parameterized in terms of six constant parameters. These parameters provide primary control design choices for not only an inverter’s terminal voltage but also its injections of both real and oscillatory power. It is shown that the proposed GFM control can precisely achieve a desired balanced terminal voltage under unbalanced loads. It is also shown that, by allowing the terminal voltage to be slightly unbalanced, oscillatory power can be adaptively minimized. Lastly, it is illustrated that oscillatory power can also be shared among multiple GFM inverters. Case studies and their simulations demonstrate that the proposed GFM control is effective in meeting the aforementioned objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Voltage Inference Framework for Real-Time Observability in Active Distribution Grids

Active distribution grids are gaining traction to meet the growing environmental, socio-economic, and sustainability targets. Various advanced smart grid technologies facilitate the integration of Distributed Energy Resources (DERs) by supporting the bi-directional power flow. The limited observability of distribution grids, primarily related to their location at the very edge of power system infrastructure, brings challenges to optimal grid management. Moreover, only a limited number of measurements at regular intervals are usually available. This paper presents a novel inference framework, referred to as “Voltage Inference”, to overcome the observability issues. The proposed framework employs a prediction step based on the Multivariate Taylor series approximation, followed by a corrector step that minimizes the estimation error to infer the otherwise unknown voltages from the available measurements. Furthermore, numerical results on the IEEE 13-bus test feeder validate the accuracy and computational performance of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Towards Resilient Design of Leader-following Consensus with Attack Identification and Privacy Preservation Capabilities

This paper considers a leader-following consensus in the presence of unknown but bounded cyber-attacks. Specifically, we consider the following cyber-attack scenarios: (i) an attacker aims to destabilize the consensus dynamics by injecting exogenous signals to both the actuators of the followers and/or the communication network, (ii) an eavesdropper adversary aims to obtain information on the physical state of the agents. To this end, a novel resilient leader-following consensus algorithm based on a competitive interaction method is proposed. In addition, it is demonstrated that by appropriately choosing the information exchanged between the agents, the proposed control framework also enables the cooperative system to either distributively identify the compromised communication links in real-time or to protect the privacy of the physical state of the agents from the eavesdropper. Here, a numerical example is provided to illustrate the proposed resilient control algorithms.

Gusrialdi, Azwirman↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Secondary Control of Grid-Forming Inverters and AC Microgrids: Impacts of Voltage Feedback Choices

In this paper, the operational choices in distributed secondary control are examined, and their impacts on grid-forming (GFM) inverters and grid operation are investigated. In particular, the effects of feedback voltage choices, either average voltage feedback (AVF) or terminal voltage feedback (TVF), are studied with respect to reactive power sharing, voltage regulation, and grid-forming operation during black start. The secondary control used is a subgradient-based distributed cooperative control, and it provides the voltage, angle, and frequency references to the GFM inverters and their primary tracking controls. The overall control architecture employs multi-rate sampling such that the secondary control is slower than the primary control. The operational choices and their control performance are illustrated using a four-GFM-inverter microgrid in MATLAB/SIMULINK. Furthermore, the results show the effectiveness of the secondary controller, and several conclusions are drawn on the voltage feedback signals as the design choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Forming Control Using TAPAS Software Defined Inverters

Here, this paper discusses the design and hardware implementation aspects of state-feedback primary control for grid forming inverters. The primary control consists of two tracking control laws: voltage tracking and frequency/angle tracking. The voltage tracking control requires voltage and current at the inverter's switch terminal (i.e. before the filter). The fundamental component of switch terminal voltage is estimated using the inverter's average model while the switch terminal current is estimated using an observer, thus obviating the need for sensors at the switch terminals. The measurements of frequency and angle(s) needed for frequency/angle tracking are noisy due to measurement noises and inherent delays in the phase locked loop (PLL). Conditioning of these feedback signals is discussed in detail, and the corresponding changes in the control design are provided to better attenuate the impact of noises. Effectiveness of the proposed design and implementation is demonstrated by the implementation results from TAPAS software defined inverter (SDI).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooperative Systems in Presence of Cyber-Attacks: A Unified Framework for Resilient Control and Attack Identification

Here, this paper considers a cooperative control problem in presence of unknown attacks. The attacker aims at destabilizing the consensus dynamics by intercepting the system’s communication network and corrupting its local state feedback. We first revisit the virtual network based resilient control proposed in our previous work and provide a new interpretation and insights into its implementation. Based on these insights, a novel distributed algorithm is presented to detect and identify the compromised communication links. It is shown that it is not possible for the adversary to launch a harmful and stealthy attack by only manipulating the physical states being exchanged via the network. In addition, a new virtual network is proposed which makes it more difficult for the adversary to launch a stealthy attack even though it is also able to manipulate information being exchanged via the virtual network. A numerical example demonstrates that the proposed control framework achieves simultaneously resilient operation and real-time attack identification.

97 MATHEMATICS AND COMPUTING↗

Resilient Hierarchical Networked Control Systems: Secure Controls for Critical Locations and at Edge

Integration of information and communication technology (ICT) offers new opportunities in improving the management and operation of critical infrastructures such as power systems as it allows connection of different sensors and control components via a communication network, leading to the so-called networked control systems (NCS). However, the use of open and pervasive ICT such as the Internet or wireless communication technologies comes at a price of making NCS vulnerable to cyber intrusions/attacks which may cause physical damage. Here, this chapter presents control algorithms to ensure resilient and safe operation of NCS under unknown cyberattacks. Specifically, a variant of dynamic watermarking strategies is presented by embedding encoding/decoding components of chaotic signals into the NCS for secure control for critical locations where the measurement/control signals are transmitted to/from the control center via a communication network. In addition, resilient cooperative control algorithms are discussed to ensure safe operation at edge of the NCS which consists of a large number of distributed controllable devices. Several numerical examples are provided to illustrate the proposed control strategies.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗