Validation of Geant4 Hadronic Generators versus Thin Target Data

The GEANT4 toolkit is widely used for simulation of high energy physics (HEP) experiments, in particular, those at the Large Hadron Collider (LHC). The requirements of robustness, stability and quality of simulation for the LHC are demanding. This requires an accurate description of hadronic interactions for a wide range of targets over a large energy range, from stopped particle reactions to low energy nuclear interactions to interactions at the TeV energy scale. This is achieved within the Geant4 toolkit by combining a number of models, each of which are valid within a certain energy domain. Comparison of these models to thin target data over a large energy range indicates the strengths and weaknesses of the model descriptions and the energy range over which each model is valid. Software has been developed to handle the large number of validation tests required to provide the feedback needed to improve the models. An automated process for carrying out the validation and storing/displaying the results is being developed and will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Description of analyzing power and (p,n) reaction by a global dispersive coupled-channel optical model potential

A global dispersive coupled-channel optical model potential is used to analyze the proton elastic/inelastic analyzing power data and (p,n) data in order to investigate the prediction power of this potential. The numerical calculations show good agreement with available experimental data for proton elastic data and overall agreement for proton inelastic data. The results also showed that present global potential is approximately Lane-consistent, and can predict well the (p,n) cross sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GEANT4 Application for the Simulation of the Head of a Siemens Primus Linac

The Monte Carlo simulation of the head of a Siemens Primus Linac used at Virgen Macarena Hospital (Sevilla, Spain) has been performed using the code GEANT4, version 9.2. In this work, the main features of the application built by our group are presented. They are mainly focused in the optimization of the performance of the simulation. The geometry, including the water phantom, has been entirely wrapped by a shielding volume which discards all the particles escaping far away through its walls. With this, a factor of four in the time spent by the simulation can be saved. An interface to read and write phase-space files in IAEA format has been also developed to save CPU time in our simulations. Finally, some calculations of the dose absorption in the water phantom have been done and compared with the results given by EGSnrc and with experimental data obtained for the calibration of the machine.

43 PARTICLE ACCELERATORS↗

Approximate Lane consistency of the dispersive coupled-channels potential for actinides

A previously derived dispersive coupled-channels optical model potential for nucleon scattering on {sup 232}Th and {sup 238}U nuclei [Capote, Soukhovitskii, Quesade, and Chiba, Phys. Rev. C 72, 064610 (2005)] has been tested against experimental data on quasielastic (p,n) scattering to the isobaric analog states of corresponding target nuclei. The Lane potential derived from the isovector term of the dispersive coupled-channels optical model potential has been shown to approximately reproduce available experimental differential cross-section data for the quasielastic (p,n) reaction; therefore the approximate Lane consistency of that potential has been established.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗