Search NASA⌕ Search

Engineering topics

Quinn, K

Publications and source records attributed to Quinn, K.

SU-E-T-338: Dosimetric Study of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) for Stereotactic Body Radiation Therapy (SBRT) in Early Stage Lung Cancer

Purpose: This study evaluates the dosimetric differences using volumetric modulated arc therapy (VMAT) in patients previously treated with intensity modulated radiation therapy IMRT for stereotactic body radiotherapy (SBRT) in early stage lung cancer. Methods: We evaluated 9 consecutive medically inoperable lung cancer patients at the start of the SBRT program who were treated with IMRT from November 2010 to October 2011. These patients were treated using 6 MV energy. The 9 cases were then re-planned with VMAT performed with arc therapy using 6 MV flattening filter free (FFF) energy with the same organs at risk (OARS) constraints. Data collected for the treatment plans included target coverage, beam on time, dose to OARS and gamma pass rate. Results: Five patients were T1N0 and four patients were T2N0 with all tumors less than 5 cm. The average GTV was 13.02 cm3 (0.83–40.87) and average PTV was 44.65 cm3 (14.06–118.08). The IMRT plans had a mean of 7.2 angles (6–9) and 5.4 minutes (3.6–11.1) per plan. The VMAT plans had a mean of 2.8 arcs (2–3) and 4.0 minutes (2.2–6.0) per plan. VMAT had slightly more target coverage than IMRT with average increase in D95 of 2.68% (1.24–5.73) and D99 of 3.65% (0.88–8.77). VMAT produced lower doses to all OARs. The largest reductions were in maximum doses to the spinal cord with an average reduction of 24.1%, esophagus with an average reduction of 22.1%, and lung with an average reduction in the V20 of 16.3% The mean gamma pass rate was 99.8% (99.2–100) at 3 mm and 3% for VMAT with comparable values for IMRT. Conclusion: These findings suggest that using VMAT for SBRT in early stage lung cancer is superior to IMRT in terms of dose coverage, OAR dose and a lower treatment delivery time with a similar gamma pass rate.

60 APPLIED LIFE SCIENCES↗

Employing laser-accelerated proton beams to diagnose high intensity laser-plasma interactions

A review of the proton radiography technique will be presented. This technique employs laser-accelerated laminar bunches of protons to diagnose the temporal and spatial characteristic of the electric and magnetic fields generated during high-intensity laser-plasma interactions. The remarkable temporal and spatial resolution that this technique can achieve (of the order of a picosecond and a few microns respectively) candidates this technique as the preferrable one, if compared to other techniques, to probe high intensity laser-matter interactions.

43 PARTICLE ACCELERATORS↗

Modified proton radiography arrangement for the detection of ultrafast field fronts

The experimental arrangement for the investigation of high-field laser-induced processes using a broadband proton probe beam has been modified to enable the detection of the ultrafast motion of field fronts. It is typical in such experiments for the target to be oriented perpendicularly with respect to the principal axis of the probe beam. It is demonstrated here, however, that the temporal imaging properties of the diagnostic arrangement are altered drastically by placing the axis (or plane) of the target at an oblique angle to the transverse plane of the probe beam. In particular, the detection of the motion of a laser-driven field front along a wire at a velocity of (0.95{+-}0.05)c is described.

43 PARTICLE ACCELERATORS↗

Relativistic Current Dynamics Investigations By Proton Probing

The proton probing technique has been used to investigate the incidence of a mid-10{sup 19} W cm{sup -2} pulse with metallic wire and laminar foam targets. Electric fields approx10{sup 10} Vcentre dotm{sup -1} are measured on the surface of the 125 mum-diameter wire in the wake of the laser interaction as it charges and discharges within a 20 ps temporal window, whilst the employment of a novel experimental technique permits the observation of the propagation of a charging front at approxc away from the point of interaction. In the foam shots, meanwhile, the behaviour of the hot electrons generated by the interaction pulse is probed inside the target. Evidence of electric inhibition effects and filamentation is found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-Driven Ultrafast Field Propagation on Solid Surfaces

The interaction of a 3x10{sup 19} W/cm{sup 2} laser pulse with a metallic wire has been investigated using proton radiography. The pulse is observed to drive the propagation of a highly transient field along the wire at the speed of light. Within a temporal window of 20 ps, the current driven by this field rises to its peak magnitude {approx}10{sup 4} A before decaying to below measurable levels. Supported by particle-in-cell simulation results and simple theoretical reasoning, the transient field measured is interpreted as a charge-neutralizing disturbance propagated away from the interaction region as a result of the permanent loss of a small fraction of the laser-accelerated hot electron population to vacuum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗