Search NASA⌕ Search

Engineering topics

Quiroz, Jimmy Edward

Publications and source records attributed to Quiroz, Jimmy Edward.

At least 19 records

Microgrid Design Toolkit (MDT) User Guide: Software v1.4

The MDT is a decision support software that can provide the information needed to identify optimal microgrid designs in the early stages of the design process. MDT searches the trade space of alternative microgrid designs in terms of user-defined objectives, such as performance, reliability, and cost. It produces a Pareto frontier of solutions embodying the efficient tradeoffs amongst multiple user-defined objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC Microgrid Protection: Review and Challenges

Successful system protection is critical to the feasibility of the DC microgrid system. This work focused on identifying the types of faults, challenges of protection, different fault detection schemes, and devices pertinent to DC microgrid systems. One of the main challenges of DC microgrid protection is the lack of guidelines and standards. The various parameters that improve the design of protection schemes were identified and discussed. Due to the absence of physical inertia, the resistive nature of the line impedance affects fault clearing time and system stability during faults. Therefore, the effectiveness of protection coordination systems with communication were also explored. A detailed literature review was done to identify possible grounding schemes and protection devices needed to ensure seamless power flow of grid-connected DC microgrids. Ultimately, it was identified that more analyses and experimentation are needed to develop optimized fault detection schemes with reduced fault clearing time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Conservative Approach to Defining Photovoltaic System Hazards to Firefighters

Sandia National Laboratories performed analysis to develop conservative hazard guidelines regarding firefighters working near photovoltaic (PV) arrays. Assuming implementation of NFPA 70 system shutdown requirements, the analysis focused on DC hazards only. Several different PV variables were considered, including system grounding and DC voltage classes. The hazard scenarios considered the contact conditions, current paths through the body, and PPE. Guidelines for the hazard definitions for men and women were based on the IEC TS 60479-1 guidelines. The importance of PPE was illustrated in the results.

14 SOLAR ENERGY↗

Cyber Security Gap Analysis for Critical Energy Systems (CSGACES)

This study describes a cyber security research & development (R&D) gap analysis and research plan to address cyber security for industrial control system (ICS) supporting critical energy systems (CES). The Sandia National Laboratories (SNL) team addressed a long-term perspective for the R&D planning and gap analysis. Investment will posture CES for sustained and resilient energy operations well into the future.

42 ENGINEERING↗

Comparison of High-Frequency Solar Irradiance: Ground Measured vs. Satellite-Derived

High-frequency solar variability is an important to grid integration studies, but ground measurements are scarce. The high resolution irradiance algorithm (HRIA) has the ability to produce 4-sceond resolution global horizontal irradiance (GHI) samples, at locations across North America. However, the HRIA has not been extensively validated. In this work, we evaluate the HRIA against a database of 10 high-frequency ground-based measurements of irradiance. The evaluation focuses on variability-based metrics. This results in a greater understanding of the errors in the HRIA as well as suggestions for improvement to the HRIA.

14 SOLAR ENERGY↗

Methods to Determine Recommended Feeder-Wide Advanced Inverter Settings for Improving Distribution System Performance

This paper describes methods that a distribution engineer could use to determine advanced inverter settings to improve distribution system performance. These settings are for fixed power factor, volt-var, and volt-watt functionality. Depending on the level of detail that is desired, different methods are proposed to determine single settings applicable for all advanced inverters on a feeder or unique settings for each individual inverter. Seven distinctly different utility distribution feeders are analyzed to simulate the potential benefit in terms of hosting capacity, system losses, and reactive power attained with each method to determine the advanced inverter settings.

14 SOLAR ENERGY↗