Search NASA⌕ Search

Engineering topics

Rabin, Michael

Publications and source records attributed to Rabin, Michael.

Thermal Microwave Kinetic Inductance Device, RSLN-023-16, Year 1 of 2

Presentation describes decay-energy spectroscopy as a transformative method for nondestructive isotopic assay of trace-level nuclear materials with potential applications in areas including nuclear forensics. This project concentrates on optimizing this technology for low-energy electron spectroscopy. Measurement of the decay by electron capture of holmium-163 (163Ho) was explored because its low energy decay, which allows accurate study of energy-resolution capabilities of decay-energy spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high-resolution alpha spectrometry for nuclear forensics and safeguards applications

We will present our work on the development of ultra-high-resolution detectors for alpha particle spectrometry. These detectors, based on superconducting transition-edge sensors, offer energy resolution that is five to ten times better than conventional silicon detectors. Using these microcalorimeter detectors, the isotopic composition of mixed-actinide samples can be determined rapidly without the need for actinide separation chemistry to isolate each element, or mass spectrometry to separate isotopic signatures that can not be resolved using traditional alpha spectrometry (e.g. Pu-239/Pu-240, or Pu-238/Am-241). This paper will cover the detector and measurement system, actinide source preparation, and the quantitative isotopic analysis of a number of forensics- and safeguards-relevant radioactive sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High rate pulse processing algorithms for microcalorimeters

It has been demonstrated that microcalorimeter spectrometers based on superconducting transition-edge-sensor can readily achieve sub-100 eV energy resolution near 100 keV. However, the active volume of a single microcalorimeter has to be small to maintain good energy resolution, and pulse decay times are normally in the order of milliseconds due to slow thermal relaxation. Consequently, spectrometers are typically built with an array of microcalorimeters to increase detection efficiency and count rate. Large arrays, however, require as much pulse processing as possible to be performed at the front end of the readout electronics to avoid transferring large amounts of waveform data to a host computer for processing. In this paper, they present digital filtering algorithms for processing microcalorimeter pulses in real time at high count rates. The goal for these algorithms, which are being implemented in the readout electronics that they are also currently developing, is to achieve sufficiently good energy resolution for most applications while being (a) simple enough to be implemented in the readout electronics and (b) capable of processing overlapping pulses and thus achieving much higher output count rates than the rates that existing algorithms are currently achieving. Details of these algorithms are presented, and their performance was compared to that of the 'optimal filter' that is the dominant pulse processing algorithm in the cryogenic-detector community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗