Search NASA⌕ Search

Engineering topics

Rael, Carlos D.

Publications and source records attributed to Rael, Carlos D..

At least 19 records

Use of a deuterium-deuterium neutron generator for the Add-A-Source waste matrix correction technique

Neutron generators offer an alternative to radioactive sources in the application of active techniques for nondestructive assay of nuclear materials. The Add-A-Source technique has enabled improvements in the ability to accurately measure waste bearing nuclear materials by measuring and correcting for the non-nuclear matrix effect. The technique has historically been performed with a Cf-252 spontaneous fission source. Here, in this work, we have demonstrated the use of a Deuterium-deuterium neutron generator in place of the Cf-252 source. A DD generator enables operational advantages and allows the simplification of the instrument design, while offering equivalent corrective performance as a Cf-252 source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of INCC6 for advanced list-mode data acquisition and analysis using ALMM

The International Neutron Coincidence Counting (INCC) software plays an important role in nuclear safeguards and nuclear material control and accounting (NMC&A) measurements. While the current version, INCC5, represents the traditional standard utilized by inspectorates as well as facilities and practitioners alongside shift register hardware, LANL has recently developed an upgraded version of the software, INCC6. INCC6 offers the same analysis tools as INCC5 while adding new capabilities including acquisition and analysis of list-mode data, recording and storage of list-mode data files, and an expanded set of advanced analysis tools that make use of the additional information available from list-mode data. Here, this paper presents the first demonstration of data acquisition and analysis using INCC6 and the Advanced List Mode Multiplicity Module (ALMM). The capability of INCC6 to perform live list-mode data acquisition and analysis is demonstrated for a variety of neutron sources with a range of neutron emission rates relevant for practical applications and validated against the results obtained with INCC5 and traditional shift register hardware. Advanced list-mode analysis tools introduced by INCC6, such as time-interval and coincidence matrix analysis, are also demonstrated. Finally, the capability of INCC6 to analyze list-mode data files is tested and validated against traditional shift register results using INCC5.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SFRC Measurement Control Summary - FY23 Q3/Q4

Measurements with the Spent Fuel Rod Counter (SFRC) to be performed bi annually include 3 He detector efficiency checks (in both modules) and ion chamber channel tests with a pocket pulser. These measurements will all be performed at TA-35, building 27 where the SFRC is stored. Refer to LA-UR-22-31737 and LA-CP-22-20079 SFRC measurement control documents for a description of additional tests. Note that during this measurement period, counts could not be confirmed for the Si detectors, as an analog pulse to TTL box necessary for the DAQs to communicate with the detectors was still under construction. For this reason, typical measurements at the Calibrated Dose Facility were not performed for the second half of FY23. When these components are finished by the NEN electrical shop, the Si detectors will be implemented into these measurement control checks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plutonium Basket Counter Measurement Control Q3-Q4 2023

The Plutonium Basket Counter (PBC) is a spent fuel nuclear safeguards instrument that was developed to measure spent-fuel elements from MAGNOX-type research reactors and determine their plutonium content. The instrument is designed to measure fuel elements in spent fuel cooling pools through underwater operation, but it is also able to measure radiation sources in air. The PBC determines fuel plutonium content by detecting neutrons with an array of Helium-3 detectors. The electronics make use of a JSR-15 shift register for data collection and IAEA Neutron Coincidence Counting (INCC) software for data analysis. The PBC is used to determine the 240 Pu content in spent MAGNOX fuel elements grouped into basket-like bundles, thus the instrument’s name. Reactor burnup calculations can be used in conjunction with the data from the PBC to estimate the total plutonium content in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved evaluation of safeguards parameters from spent fuel measurements with the Differential Die-Away (DDA) instrument

The Differential Die-Away (DDA) technique is a highly sensitive non-destructive assay method for characterizing and detecting the presence of fissile material within an item of interest. DDA utilizes a series of pulses from a neutron generator (NG) to actively interrogate an item of interest. The die-away time of the neutron population induced by this active interrogation and the integral of the total differential die-away signal can be used to characterize items such as nuclear waste drums and spent nuclear fuel assemblies. In this work, Los Alamos National Laboratory (LANL) conceptualized, designed, and fabricated a DDA instrument that was deployed for field test measurements at the Central Interim Storage Facility for Spent Nuclear Fuel (Clab) in Oskarshamn, Sweden. The instrument performed multiple static measurements at fixed locations and dynamic axial scans of 15 pressurized water reactor (PWR) and 10 boiling water reactor (BWR) spent fuel assemblies, collecting both passive and active measurement data. The static assays of the assemblies measured the differential die-away signal, die-away time, and total passive neutron emission rate to create calibration curves for the evaluation of assembly multiplication, burnup, initial enrichment, effective fissile mass, and total elemental plutonium mass. Each calibration curve was optimized by minimizing the relative root mean square error (RRMSE) of assembly assay results compared to declared assembly parameters. The same quantities were also measured with the axial scans, and the resulting data were applied in two ways: (1) in the creation of calibration curves to improve evaluation of the same safeguards parameters as static assays, and (2) for comparison to simulation. In most cases, across both PWR and BWR assemblies, axial scan data improved the estimation of the above parameters, quantified by decreasing the calibration curve RRMSE. These axial scan results demonstrate the ability of the DDA instrument and analysis method to characterize spent PWR and BWR fuel as well as, or better than, a static assay of the same assembly. Furthermore, the DDA instrument’s unique ability to obtain both active and passive data in a single, axial scan of an entire spent fuel assembly represents a more efficient and accurate way of assaying spent fuel for verification purposes. These results represent a significant advancement for characterizing spent nuclear fuel compared to current technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new generation of uranium coincidence fast neutron collars for assay of LWR fresh fuel assemblies

The active uranium neutron coincidence collar provides a means of non-destructively assaying the fissile linear density of Light Water Reactor fresh fuel assemblies containing low enriched uranium. These neutron collars can operate in two modes: a thermal and a fast mode. In fast mode, a neutron collar has an added cadmium (Cd) liner in the sample cavity of the detector to reduce the impact of the burnable poison (thermal neutron absorber) on the detector signal (doubles). The main advantage for operating in fast mode is a detected signal that is less dependent of the burnable neutron poison content and thus less dependent on facility operator declarations. The drawback is that operating in fast mode requires a longer measurement time (~hour vs tens of minutes for thermal mode) to achieve the statistically needed precision in the measurements. The trend in the modern reactor fuel assemblies is moving to higher burnup by using higher initial enrichment and, consequently, a higher number of burnable poison rods to compensate the initial neutron reactivity. The increase of the burnable poison loading has motivated the development of a new generation of high efficiency fast neutron collars to allow practical measurements in-field by nuclear inspectors. This paper describes the development and performance evaluation of a new generation of neutron collars, for both boiling water reactor (BWR) and pressurized water reactor (PWR) fuels, jointly developed between the US Department of Energy, through Los Alamos National Laboratory, and the Euratom Safeguards Directorate of the European Commission. In this work, we present here calibrations with reference fuel assemblies at Los Alamos National Laboratory as well as the results of in-field measurement campaigns in fuel fabrication plants with modern commercial fuel assemblies. The experimental results show that a typical PWR verification can be made in a total time of 30 min with an uncertainty in the measured mass of 2% at one standard deviation (1σ). A BWR verification can be made in 47 min with an uncertainty in the measured mass of 1.9% at 1σ, or a total time of 20 min with 1σ uncertainty in the measured mass of 2.5%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UFCC Calibration Measurements for Bulk U 3 O 8 Powder Samples

The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF 6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252 Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. The sample enrichments varied from 0.72% to 91% to establish the shape of the calibration curve and the measurement uncertainties. The measurements included the singles, doubles, and triples rates. The time correlations between the 252 Cf source and the induced fission reactions reduced the statistical error in the doubles and triples rates to be small enough for useful measurements in 5-10 minutes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UFCC Calibration Measurements for UO2 Samples

The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252 Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. A customized HDPE insert was designed to position the 252 Cf source under the UO 2 sample cans. The sample enrichments varied from depleted to 93% to establish the shape of the calibration curve and the measurement uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EURATOM Fast Collar for BWR (EFCB) Field Calibration Exercise

A neutron collar for the measurement of fresh BWR fuel assemblies (EFCB) has been designed and built by Los Alamos National Laboratory (LANL) and the Euratom Safeguards Directorate (Euratom). The design was similar to a previous collar designed for the measurement of fresh PWR assemblies. A key feature of both of these collars is that they operate in fast mode (preventing the return of thermal neutrons into the assembly by means of a cadmium liner) to reduce the effect of burnable poisons on the measurement. The current report describes the results of the field calibration exercise that was carried out at the ENUSA Fuel Fabrication Plant in Juzbado, Spain from May 28 to May 31, 2019.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Annual IPCA2 Performance Report for JFY18

This report summarizes the results of monthly control measurements of IPCA2 performed over the period of October 2018 through March 2019 and represents an annual performance overview for JFY18. Note that the start of the measurements in October 2018 was defined by the start of the contract agreement. Monthly measurements of Plutonium neutron detection efficiency, AmLi stability, Curium stability and HPGe gamma spectra of Plutonium standards were performed and analyzed. All the results are shown with respect to original control bounds established from 2013- 2017 data in. Updated control bounds established based on this JFY18 data for use during JFY19 measurements are summarized in Appendix A. Based on Pu efficiency measurements, the performance of the IPCA2 during this reporting period was stable within 0.6% at 1 σ level. Measurements were compared to room temperature and humidity and no dependence was found for any detector performance. The end of this report contains summary of all IPCA2 measurements performed since October 2018 and includes discussion of troubleshooting and repair activities performed over the reporting period.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new method to measure the U-235 content in fresh LWR fuel assemblies via fast-neutron passive self-interrogation

The purpose of this paper is to provide a solution to a decades old safeguards problem in the verification of the fissile concentration in fresh light water reactor (LWR) fuel assemblies. The problem is that the burnable poison (e.g. Gd 2 O 3 ) addition to the fuel rods decreases the active neutron assay for the fuel assemblies. This paper presents a new innovative method for the verification of the 235 U linear mass density in fresh LEU fuel assemblies that is insensitive to the burnable poison content. The technique makes use of the 238 U atoms in the fuel rods to self-interrogate the 235 U mass. The innovation for the new approach is that the 238 U spontaneous fission (SF) neutrons from the rods induces fission reactions (IF) in the 235 U that are time correlated with the SF source neutrons. Thus, the coincidence gate counting rate benefits from both the nu-bar of the 238 U SF (2.07) and the 235 U IF (2.44) for a fraction of the IF reactions. Whereas, the 238 U SF background has no time-correlation boost. The higher the detection efficiency, the higher the correlated boost because background neutron counts from the SF are being converted to signal doubles. This time-correlation in the IF signal increases signal/background ratio that provides a good precision for the net signal from the 235 U mass. The hard neutron energy spectrum makes the technique insensitive to the burnable poison loading where a Cd or Gd liner on the detector walls is used to prevent thermal-neutron reflection back into the fuel assembly from the detector. Here, we have named the system the fast-neutron passive collar (FNPC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical basis for the use of a correlated neutron source in the uranium neutron coincidence collar

Active neutron coincidence systems are commonly used by international inspectorates to verify a material balance across the various stages of the nuclear fuel cycle. The Uranium Neutron Coincidence Collar (UNCL) is one such instrument; it is used to measure the linear density of 235 U (g 235 U/cm of active length in assembly) in fresh light water reactor fuel in nuclear fuel fabrication facilities. The UNCL and other active neutron interrogation detectors have historically relied on americium lithium ( 241 AmLi) sources to induce fission within the sample in question. Californium-252 is under consideration as a possible alternative to the traditional 241 AmLi source. Finally, this work relied upon a combination of experiments and Monte Carlo simulations to demonstrate the technical basis for the replacement of 241 AmLi sources with 252 Cf sources by evaluating the statistical uncertainty in the measurements incurred by each source and assessing the penetrability of neutrons from each source for the UNCL.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of Techniques for Spent Fuel Assay – Differential Dieaway Final Report

This report summarizes the work done under a DNDO R&D funded project on the development of the differential dieaway method to measure plutonium in spent fuel. There are large amounts of plutonium that are contained in spent fuel assemblies, and currently there is no way to make quantitative non-destructive assay. This has led NA24 under the Next Generation Safeguards Initiative (NGSI) to establish a multi-year program to investigate, develop and implement measurement techniques for spent fuel. The techniques which are being experimentally tested by the existing NGSI project do not include any pulsed neutron active techniques. The present work covers the active neutron differential dieaway technique and has advanced the state of knowledge of this technique as well as produced a design for a practical active neutron interrogation instrument for spent fuel. Monte Carlo results from the NGSI effort show that much higher accuracy (1-2%) for the Pu content in spent fuel assemblies can be obtained with active neutron interrogation techniques than passive techniques, and this would allow their use for nuclear material accountancy independently of any information from the operator. The main purpose of this work was to develop an active neutron interrogation technique for spent nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗