Advances in Image-Domain Multi-Resolution and Super-Resolution Algorithms for Industrial X-Ray Computed Tomography: A Literature Survey and New Insights

Industrial X-ray Computed Tomography (XCT) is a nondestructive method for inspection and character ization of materials and parts. XCT captures images of a part from various angles, and these images are then used to construct Three-Dimensional (3D) representations of that part. This method enables assessing the quality of the parts, identifying defects and understanding their physical properties without damaging them.

36 MATERIALS SCIENCE↗

2.5D Super-Resolution Approaches for X-Ray Computed Tomography-Based Inspection of Additively Manufactured Parts

X-ray computed tomography (XCT) is a key tool in non-destructive evaluation of additively manufactured (AM) parts, allowing for internal inspection and defect detection. Despite its widespread use, obtaining high-resolution CT scans can be extremely time consuming. This issue can be mitigated by performing scans at lower resolutions; however, reducing the resolution compromises spatial detail, limiting the accuracy of defect detection. Super-resolution algorithms offer a promising solution for overcoming resolution limitations in XCT reconstructions of AM parts, enabling more accurate detection of defects. While 2D super-resolution methods have demonstrated state-of-the-art performance on natural images, they tend to under-perform when directly applied to XCT slices. On the other hand, 3D super-resolution methods are computationally expensive, making them infeasible for large-scale applications. To address these challenges, we propose a 2.5D super-resolution approach tailored for XCT of AM parts. Our method enhances the resolution of individual slices by leveraging multi-slice information from neighboring 2D slices without the significant computational overhead of full 3D methods. Specifically, we use neighboring low-resolution slices to super-resolve the center slice, exploiting inter-slice spatial context while maintaining computational efficiency. This approach bridges the gap between 2D and 3D methods, offering a practical solution for high-throughput defect detection in AM parts.

Sullivan, Haley↗

Deep Learning Based Workflow for Accelerated Industrial X-Ray Computed Tomography

X-ray computed tomography (XCT) is an important tool for high-resolution non-destructive characterization of additively-manufactured metal components. XCT reconstructions of metal components may have beam hardening artifacts such as cupping and streaking which makes reliable detection of flaws and defects challenging. Furthermore, traditional workflows based on using analytic reconstruction algorithms require a large number of projections for accurate characterization - leading to longer measurement times and hindering the adoption of XCT for in-line inspections. In this paper, we introduce a new workflow based on the use of two neural networks to obtain high-quality accelerated reconstructions from sparse-view XCT scans of single material metal parts. The first network, implemented using fully-connected layers, helps reduce the impact of BH in the projection data without the need of any calibration or knowledge of the component material. The second network, a convolutional neural network, maps a low-quality analytic 3D reconstruction to a high-quality reconstruction. Using experimental data, we demonstrate that our method robustly generalizes across several alloys, and for a range of sparsity levels without any need for retraining the networks thereby enabling accurate and fast industrial XCT inspections.

Rahman, Obaid↗

Neural network-based single material beam-hardening correction for X-ray CT in Additive Manufacturing

Beam-hardening (BH) artifacts are ubiquitous in X-ray CT scans of dense metal additively manufactured (AM) parts. While linearization approaches are useful for correcting beam-hardened data from single material objects, they either require a calibration scan or detailed system and material composition information. In this paper, we introduce a neural network-based, material-agnostic method to correct beam-hardening artifacts. We train a neural network to map the acquired beam-hardened projection values and the corresponding estimated thickness of the part based on an initial segmentation to beam-hardening related parameters, which can be used to compute the coefficients of a linearizing correction polynomial. A key strength of our approach is that, once the network is trained, it can be used for correcting beam hardening from a variety of materials without any calibration scans or detailed system and material composition information. Furthermore, our method is robust to errors in the estimated thickness due to the typical challenge of obtaining an accurate initial segmentation from reconstructions impacted by BH artifacts. We demonstrate the utility of our method to obtain high-quality CT reconstructions from a collection of AM parts -- suppressing cupping and streaking artifacts

Rahman, Obaid↗