Fatigue in Multidirectional Composites

Data in new report on fatique properties of graphite/epoxy composites prove valuable to designers of aircraft, space vehicles, and automobiles. Graphite/epoxy composites are being used increasingly in lightweight load-bearing structures, and fatigue of such structures is always major concern of designers.

Ramani, S. V.

Effect of moisture on the fatigue behavior of graphite/epoxy composite laminates

The form of the moisture distribution in the specimen (gradient and flat profile) was considered to establish the influence of accelerated moisture conditioning on fatigue behavior. For the gradient specimens having an average moisture content of 1.4 percent, fatigue life was reduced by a factor of 8 at all stress levels investigated. Corresponding reduction in fatigue life for the flat moisture profile specimens at the same average moisture content was comparatively smaller, being about a factor of 5 from the value in dry specimens. X-ray radiographic analysis of damage accumulation in compression-compression fatigue revealed interlaminar cracking to be the dominant mode of failure responsible for the observed enhanced cyclic degradation of moisture-conditioned specimens. This finding was corroborated by the observed systematic reduction in interlaminar shear strength as a function of moisture content, which, in turn, increased the propensity for delamination under cyclic compressive loads. Residual strength measurements on cycled specimens indicated significant strength reductions at long lives, particularly in moisture conditioned specimens.

Ramani, S. V.

Notched and unnotched fatigue behavior of angle-ply graphite/epoxy composites

The axial fatigue behavior of both notched and unnotched graphite/epoxy composites has been studied as part of a continuing research investigation. In unnotched studies, conducted on an AS/3501 laminate, S-N curves were determined for various stress ratios R using simply supported test specimens. Specimens were fatigue tested up to 5 x 10 to the 6th cycles. Apparent fatigue limits in tension-tension and compression-compression cycling occurred at about 60 percent of the respective static strengths. The overall results were expressed in the form of a constant life diagram (that is, a Goodman diagram) showing the relationship between mean stress and stress amplitude. The diagram shows a linear relationship and illustrates a skew-symmetry in fatigue life caused by the relatively low compressive strength of the unrestrained test specimens used. In effect, a maximum in stress amplitude occurs at a positive value of the mean stress.

Ramani, S. V.

Notched and Unnotched Fatigue Behavior of Angle-Ply Graphite/Epoxy Composites

The axial fatigue behavior of both notched and unnotched graphite/epoxy composites was studied. In unnotched studies, conducted on a 0/+ or - 30 3S AS/3501 laminate, S-N curves were determined for various stress ratios R using simply supported test specimens. Apparent fatigue limits in tension-tension (T-T) and compression-compression (C-C) cycling occurred at about 60% of the respective static strengths. The overall results were expressed in the form of a constant life diagram showing the relationship between mean stress and stress amplitude. The diagram illustrates a skew-symmetry in fatigue life caused by the relatively low compressive strength of the unrestrained test specimens used. In effect, a maximum in fatigue properties occurs at a positive value of mean stress. Results are of significance in situations where structural members are buckling or crippling critical in design.

Ramani, S. V.

Axial fatigue of /0, +30, and -30 deg/6s graphite/epoxy

Results are presented for an investigation carried out on a /0, +30, and -30 deg/6s graphite/epoxy angle-ply laminate in order to characterize the overall fatigue behavior, to evaluate strength/moduli degradation due to cyclic loading, and to identify the failure modes and mechanisms. The specimen life determined from fatigue tests is measured as a function of cyclic stress amplitude for various stress ratios. Fractured specimens are sectioned and examined by conventional metallography and SEM to reveal failure modes and mechanisms. It is shown that the laminate studied is susceptible to axial fatigue failures under cyclic loading which involves both tensile and compressive mean stresses. Fracture surface observations indicate the occurrence of complex failure modes. A variety of local failure mechanisms are identified.

Ramani, S. V.

Fracture and fatigue of discontinuously reinforced copper/tungsten composites

The strength, toughness and resistance to cyclic crack propagation of composites consisting of copper reinforced with short tungsten wires of various lengths have been studied and the results compared with the behavior of continuously reinforced composites manufactured by the same method, i.e., by vacuum hot-pressing. It has been found that whereas the resistance to fatigue crack growth of continuously reinforced composites is very similar to that of continuous Al/stainless steel composites reported elsewhere, the addition of short fibers completely changes the mode of fracture, and no direct comparisons are possible. In effect, short fibers inhibit single crack growth by causing plastic flow to be distributed rather than localized, and although these composites are much less strong than continuous fiber composites, they nevertheless have much greater fatigue resistance.