Search NASA⌕ Search

Engineering topics

Ramaswamy, Harisankar

Publications and source records attributed to Ramaswamy, Harisankar.

Acoustic sensing and autoencoder approach for abnormal gas detection in a spent nuclear fuel canister mock-up

Currently, spent nuclear fuel (SNF) from commercial nuclear power plants is stored in stainless-steel canisters for interim dry storage. To provide an inert environment, these canisters are backfilled with helium after vacuum drying. However, the helium environment may be contaminated during extended storage because of the material degradation. For example, the heavier fission gas xenon may be released from the fuel rods into the canister cavity should the fuel cladding be breached. Other gases such as air and water vapor may also be present as a result of leakage caused by chloride-induced stress corrosion cracking on the canister walls or by insufficient vacuum drying. Therefore, monitoring the gas composition can provide critical information about the health of SNF canisters. In this study, noninvasive testing was conducted on a 2/3-scaled SNF canister mock-up using acoustic sensing. Ultrasonic transducers were placed on the exterior surface of the canister to probe the gas composition. A dataset was collected by sealing the canister mock-up and introducing up to 1.53% argon or 1.29% air into the helium background gas. Three methods were used to detect changes in the gas composition: the time-of-flight (TOF) method, the differential method, and the autoencoder method. Results showed that the TOF method had sufficient resolution to detect abnormal gas concentrations of less than 1.0%. The differential method demonstrated a periodic in-phase and out-of-phase behavior between the benchmark (i.e., pure helium) and abnormal (i.e., with argon or air) state signals. The variational autoencoder (VAE) and the Wasserstein autoencoder (WAE) were trained on the benchmark data and were applied directly to the abnormal state data. It was found that both the unsupervised VAE and the WAE were able to distinguish the benchmark and abnormal states of the canister mock-up based on the reconstruction error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impurity gas detection for SNF canisters using probabilistic deep learning and acoustic sensing *

Abstract Monitoring impurity gases in spent nuclear fuel (SNF) canisters is a novel structural health monitoring approach for SNF in dry storage. The SNF canisters are sealed containers that do not facilitate visual access to the inside. Acoustic sensing can be deployed by taking advantage of the pathways unobstructed by internal hardware. Although the ultrasonic time-of-flight measurement can provide valuable information, it is limited in its ability to discern the concentration of only one impurity gas. As such, deep learning algorithms, particularly convolutional neural networks (CNNs), offer a promising solution. In this study, CNN-based probabilistic deep learning models were implemented to detect and quantify multiple impurity gases in helium. An experimental platform was established to simulate canister conditions, and ultrasonic test data were collected. The presence of argon and air in helium at concentrations ranging from 0% to 1.2% at increments of 0.05% was considered. The multi-layer perceptron, decision tree, and logistic regression classifiers achieved high accuracies when distinguishing pure helium from helium with impurities. CNN with dropout layers and CNN using maximum likelihood estimation showed a similar performance, indicating their ability to capture uncertainties. The ensemble CNN model exhibited improved predictions and the ability to balance individual gas concentration by integrating 1D- and 2D-CNN models. These findings contribute probabilistic deep learning solutions for impurity gas detection and analysis within SNF canisters, thus ensuring safe storage and management of SNFs.

47 OTHER INSTRUMENTATION↗

Impurity gas monitoring using ultrasonic sensing and neural networks: forward and inverse problems

Ultrasonic sensing is a non-invasive technique for monitoring impurity gas composition in various industrial applications where safety and regulatory compliance are crucial. In this study, ultrasonic sensing and neural networks were used to analyze impurity gases (i.e., air and argon) in helium. An experimental platform was established to acquire ultrasonic data. In the forward problem, an artificial neural network (ANN) model was used to forecast the response and time-of-flight (TOF) based on the excitation, and argon and air concentrations. The inverse problem was solved using a convolutional neural network (CNN) to predict the argon and air concentrations given the ultrasonic response and excitation. The results showed that the ANN accurately predicted the ultrasonic response and the change in TOF with concentration. As the air concentration was increased from 0 to 9.8%, the TOF sensitivity to detect argon decreased by 39.8% and 16.1% from ANN and sound speed theory, respectively. The CNN demonstrated high accuracy in predicting concentrations for inputs in the testing dataset. The application of the trained CNN indicated that it over-predicts air concentration while under-predicting the argon concentration. To improve accuracy, the predicted air and argon concentrations should be corrected by -0.992% and 1.027% bias, respectively.

47 OTHER INSTRUMENTATION↗

Development and experimental verification of an active noise cancellation (ANC) method for non-invasive sensing

Ultrasonic wave propagation may be used in non-invasive sensing to identify the properties of a fluid in a container. An ultrasonic excitation can be coupled into the liquid or the gas through the walls of the container and detected by a receiver on the other side. However, in addition to this fluid path, another signal will also propagate through the structure and is referred as noise in this study. For most materials, this structural noise will be of higher amplitude compared to the fluid signal due to the large acoustic impedance difference between the solid container and the fluid. In this paper, an active noise cancellation (ANC) method is developed and demonstrated on an experimental setup. It was shown that this method cancels more than 90% of the noise signal in a given time window of interest. A sequential version of this cancellation method is also proposed, and it was shown that its performance improves as the number of canceling excitations is increased. The performance was found to be independent of the location of canceling transducers and position of the silence window but dependent on the width of the silence window. As an example, the ANC method was applied to noise cancellation of a signal travelling through water in a stainless-steel container. The signal-to-noise ratio (SNR) of the water signal in the window of interest was increased by 148% from 13.98 dB to 34.68 dB by using the proposed ANC method.

42 ENGINEERING↗