Label-Free Multiphoton Imaging of Microbes in Root, Mineral, and Soil Matrices with Time-Gated Coherent Raman and Fluorescence Lifetime Imaging
Not Available
Engineering topics
Publications and source records attributed to Ramon, Christina E..
Not Available
Not Available
We provide a concise summary of analyses of a natural uranium sample seized in Slovakia in November 2007. Results are presented for compound identification, water content, U assay, trace element abundances, trace organic compounds, isotope compositions for U, Pb, Sr and O, and age determination using the 234 U – 230 Th and 235 U – 231 Pa chronometers. The sample is a mixture of two common uranium compounds - schoepite and uraninite. The uranium isotope composition is indistinguishable from natural; 236 U was not detected. The O, Sr and Pb isotope compositions and trace element abundances are unremarkable. The 234 U – 230 Th chronometer gives an age of 15.5 years relative to the date of analysis, indicating the sample was produced in January 1997. A comparison of the data for this sample with data in the Uranium Sourcing database failed to find a match, indicating the sample was not produced at a facility represented in the database.
Full nuclear forensics analysis of the two samples is complete. All uranium isotopic analyses indicate that both samples are weapons-usable, highly enriched uranium. Therefore, both seizures indicate that the statutes of the country of Texmex regarding the transport of uranium materials have been violated (>1 gram, >1% enriched in U235). Isotopic analysis by multicollector inductively coupled plasma-mass spectrometry (MC-ICP-MS) indicates that the two samples (Sample A, Sample B) have isotopic compositions that differ outside analytical uncertainty (k=2). The model ages of the two samples (apparent time since last chemical separation of parent and daughter nuclides) also differ outside analytical uncertainty (k=2). These results would indicate that, even with all of the other similarities between the two samples, the two questioned samples originate from different source materials.
The purpose of this standard operating procedure (SOP) is to provide an assay for testing the hypothesis that two samples are from the same sub-population, which can mean they came from the same batch, set of replicate batches, or the same process. The outcome is a likelihood ratio, which should be used in combination with prior odds to determine the posterior odds of the two samples coming from the same sub-population. Note that the term “match” is not used because it is imprecise in the context of determining the relationship between two samples. Under this SOP, inductively coupled plasma mass spectrometer (ICP-MS) is used to generate elemental composition data, which is used to test the hypothesis that two samples come from the same sub-population. ICP-MS is a highly sensitive bulk analysis method. The quantity of sample required is ultimately determined by the instrumentation used and the elements selected for generating ROC curves. This SOP specifies that greater than 5 mg of sample be used to enable accurate weights to be obtained for the sample in tared 3 mL Teflon vials. However, we have conducted preliminary assays with our instrumentation that suggest that sample quantity can be reduced to 50 micrograms if elemental abundances are normalized to total metal content (see Step 10). We use ICP-MS because it is the most sensitive method for determining the concentration of the largest number of elements. Other elemental analysis methods could be used to generate data for this test (e.g., ICP-OES), but specific tests would be necessary to work out the SOP.