Search NASA⌕ Search

Engineering topics

Ramos, Kyle

Publications and source records attributed to Ramos, Kyle.

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗

Visualization of shocked material instabilities using a fast-framing camera and XFEL four-pulse train

Many questions regarding dynamic materials could be answered by using time-resolved ultra-fast imaging techniques to characterize the physical and chemical behavior of materials in extreme conditions and their evolution on the nanosecond scale. In this work, we perform multi-frame phase-contrast imaging (PCI) of micro-voids in low density polymers under laser-driven shock compression. At the Matter in Extreme Conditions (MEC) Instrument at the Linac Coherent Light Source (LCLS), we used a train of four x-ray free electron laser (XFEL) pulses to probe the evolution of the samples. To visualize the void and shock wave interaction, here, we deployed the Icarus V2 detector to record up to four XFEL pulses, separated by 1-3 nanoseconds. In this work, we image elastic waves interacting with the micro-voids at a pressure of several GPa. Monitoring how the material’s heterogeneities, like micro-voids, dictate its response to a compressive wave is important for benchmarking the performances of inertial confinement fusion energy materials. For the first time in a single sample, we have combined an ultrafast x-ray framing camera and four XFEL pulse train to create an ultrafast movie of micro-void evolution under laser-driven shock compression. Eventually, we hope this technique will resolve the material density as it evolves dynamically under laser shock compression.

fusion↗

Unraveling the implications of finite specimen size on the interpretation of dynamic experiments for polycrystalline aluminum through direct numerical simulations

Normal and Pressure-shear plate impact (NPI and PSPI) experiments are popular experimental techniques for studying the mean-field macroscopic behavior of polycrystalline metals under high-rate dynamic loading. However, since both configurations rely upon geometry for subjecting the specimen to high strain rates, these experiments often involve a limited specimen size. Moreover, because of the inherent heterogeneities present within polycrystalline metals, it is difficult to ascertain if the size of the specimen and/or regions where measurements are made are sufficiently large for making representative inferences about the mean-field macroscopic properties from single-point velocity measurements. In the present study, we quantify the expected measurement variability on observable point measurements in NPI and PSPI experiments by carrying out direct numerical simulations (DNS) of statistically representative polycrystalline microstructures subjected to dynamic compression and compression-shear loading. In particular, we consider the role of specific material heterogeneities (e.g. the grain-to-grain difference in size, crystallographic orientation) on dispersion in the normal and transverse particle velocity records and on local fluctuations in key state variables (e.g. velocity, accumulated plastic strain) by incorporating these effects directly into a representative synthetic microstructure geometry and crystalline description of pure polycrystalline aluminum. The form of the present study is a large parametric investigation, consisting of ten ensembles of one hundred simulations. Each of the thousand simulations reflects a randomly realized synthetic microstructure in one of five cases of decreasing average grain size for the two loading configurations. Our analysis of the DNS results demonstrates that for both of these experimental configurations, the grain size directly correlates with the coefficient of variation (CV) in simulated point measurements, showing a convergent decrease in CV to zero (i.e. particle velocity record approaches the mean-field value) with decreasing grain size. Remarkably, the magnitude of variations in the particle velocity record is shown to be largest where the deviatoric stresses are most significant. In the case of NPI, this occurs at the elastic and plastic wavefront, whereas, in the case of PSPI, the magnitude of fluctuations are approximately constant throughout the experimental window time. The reasoning for the scatter in particle velocity due to the heterogeneous microstructure is demonstrated to be dependent on the mechanisms for accommodating deformation and on the interaction of reflection waves generated at sites of heterogeneities occurring at the scale of grains. Lastly, we develop a power-law description for the magnitude of scattering versus characteristic length, which provides a statistical framework for assessing the required number of grains per characteristic specimen dimension for minimizing scatter within these two experimental configurations (NPI, PSPI).

36 MATERIALS SCIENCE↗

Ultrafast X-ray Diffraction Study of a Shock-Compressed Iron Meteorite above 100 GPa

Natural kamacite samples (Fe92.5Ni7.5) from a fragment of the Gibeon meteorite were studied as a proxy material for terrestrial cores to examine phase transition kinetics under shock compression for a range of different pressures up to 140 GPa. In situ time-resolved X-ray diffraction (XRD) data were collected of a body-centered cubic (bcc) kamacite section that transforms to the high-pressure hexagonal close-packed (hcp) phase with sub-nanosecond temporal resolution. The coarse-grained crystal of kamacite rapidly transformed to highly oriented crystallites of the hcp phase at maximum compression. The hcp phase persisted for as long as 9.5 ns following shock release. Comparing the c/a ratio with previous static and dynamic work on Fe and Fe-rich Fe-Ni alloys, it was found that some shots exhibit a larger than ideal c/a ratio, up to nearly 1.65. This work represents the first time-resolved laser shock compression structural study of a natural iron meteorite, relevant for understanding the dynamic material properties of metallic planetary bodies during impact events and Earth’s core elasticity.

36 MATERIALS SCIENCE↗

X-ray Diffraction and Multi-Frame Phase Contrast Imaging Diagnostics for IMPULSE at the Advanced Photon Source

The diagnostic needs of any dynamic loading platform present unique technical challenges that must be addressed in order to accurately measure in situ material properties in an extreme environment. The IMPULSE platform (IMPact system for Ultrafast Synchrotron Experiments) at the Advanced Photon Source (APS) is no exception and, in fact, may be more challenging, as the imaging diagnostics must be synchronized to both the experiment and the 60 ps wide x-ray bunches produced at APS. The technical challenges of time-resolved x-ray diffraction imaging and high-resolution multi-frame phase contrast imaging (PCI) are described in this paper. Example data from recent IMPULSE experiments are shown to illustrate the advances and evolution of these diagnostics with a focus on comparing the performance of two intensified CCD cameras and their suitability for multi-frame PCI. The continued development of these diagnostics is fundamentally important to IMPULSE and many other loading platforms and will benefit future facilities such as the Dynamic Compression Sector at APS and MaRIE at Los Alamos National Laboratory.

IMPULSE, x-ray, diffraction, PCI, imaging↗