Search NASA⌕ Search

Engineering topics

Ramsey, Brian

Publications and source records attributed to Ramsey, Brian.

90 records · Page 5

The X-ray Polarimetry Explorer (XPE)

We present details of a Thomson scattering polarimeter suitable for a small-explorer- class mission. Termed XPE, for X-Ray Polarimetry Explorer, the instrument consists of a beryllium scattering cone surrounded by an annular multiwire proportional counter which registers the energy and position of scattered source photons. The polarimeter is sensitive over an energy range of 7-27 keV and will achieve 3% minimum detectable polarization of Her X-1 in a 1/2-day observation, and cover a 30-target core observation program, at the same sensitivity level, in approximately 8 months.

Ramsey, Brian↗

Electrodeposition of High Quality Nickel Phosphorous Alloys for Pollution Reduction and Energy Conservation

NASA and the University of Alabama in Huntsville have developed ecologically friendly, versatile nickel and nickel cobalt phosphorous electroplating processes. Solutions show excellent performance with high efficiency for vastly extended throughput. Properties include, clean, low temperature operation (40 - 60 C), high Faradaic efficiency, low stress and high hardness. A variety of alloy and plating speed options are easily achieved from the same chemistry using soluble anodes for metal replacement with only 25% of the phosphorous additions required for electroless nickel. Thick deposits are easily achieved unattended, for electroforming freestanding shapes without buildup of excess orthophosphate or stripping of equipment.

Engelhaupt, Darell↗

Electrocomposite of Alumina in Nickel Matrix

Nickel/aluminum oxide composite was electroformed in a sulfamate bath with 50 g/L of 0.05-micron aluminum oxide powder. Different plating methods including direct current plating, periodic pulse plating, and periodic reverse pulse plating were used. With conventional direct current plating, the maximum particle inclusion in the nickel matrix remains about 2% (wt). However, much higher percentile particle inclusions were achieved when a specific pulse reversal plating technique was applied. The particle incorporation approaches theoretical maximum when the deposit thickness per cycle approaches the particle diameter size at lower duty cycle. The highest particle incorporation achieved is 23% (by weight). Conceptual models interpreting the dramatic differences in the results of these plating methods were also proposed.

Xiong-Skiba, Pei↗

Performance of Gas Scintillation Proportional Counter Array for High-Energy X-Ray Observatory

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a High Energy X-Ray Observatory (HERO) is developed at the Marshall Space Flight Center. The array is consisted from eight GSPCs and is a part of balloon born payload scheduled to flight in May 2004. These detectors have an active area of approximately 20 square centimeters, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approximately 500 microns. The detector's energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Results of the on-earth detector calibration will be presented and in-flight detector performance will be provided, as available.

Gubarev, Mikhail↗

AS04-AS02-133 Electroformed-Nickel Hard-X-Ray Optic Development at NASA/MSFC

We are developing the nickel electroforming process to fabricate high-quality mirrors for the region. Two applications for these optics are a balloon-borne payload, termed HERO, and a hard-X-ray telescope module for consideration for the Constellation-X mission. In the formation on shells, of 15 arcsec angular resolution, will provide over 200 sq cm of effective collecting area unprecedented sensitivity in the 20-75 keV region. A first flight of a partial payload, feature approximately 1/4 of the total collecting area, is scheduled for the Spring of 2004. In the Co-application, two mirror shells, of diameters 150 and 230 mm, are being fabricated. This is particularly challenging as high angular resolution must be maintained with shells of only 1 mm thickness (driven by the tight weight budget for the mission). Further, the shells must be low (less than 5 A on sub-micron spatial scales) to permit efficient use of planned multilayer coatings which must release cleanly from their forming mandrels without any surface degradation.

Ramsey, Brian↗

Charge Loss and Charge Sharing Measurements for Two Different Pixelated Cadmium-Zinc-Telluride Detectors

As part of ongoing research at Marshall Space Flight Center, Cadmium-Zinc- Telluride (CdZnTe) pixilated detectors are being developed for use at the focal plane of the High Energy Replicated Optics (HERO) telescope. HERO requires a 64x64 pixel array with a spatial resolution of around 200 microns (with a 6m focal length) and high energy resolution (< 2% at 60keV). We are currently testing smaller arrays as a necessary first step towards this goal. In this presentation, we compare charge sharing and charge loss measurements between two devices that differ both electronically and geometrically. The first device consists of a 1-mm-thick piece of CdZnTe that is sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). The signal is read out using discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe that is sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). Instead of using discrete preamplifiers, the crystal is bonded to an ASIC that provides all of the front-end electronics to each of the 256 pixels. what degree the bias voltage (i.e. the electric field) and hence the drift and diffusion coefficients affect our measurements. Further, we compare the measured results with simulated results and discuss to

Gaskin, Jessica↗

Figure Measurements of High-Energy-X-Ray Replicated Optics

We are developing grazing incidence x-ray optics for a balloon-borne hard-x-ray telescope (HERO). The HERO mirror shells are fabricated using electroform-nickel replication off super-polished cylindrical mandrels. One of the sources for mirror resolution error is departure of the shell figure from prescription. We have modified a Vertical-scan Long Trace Profilometer (VLTP) in order to measure the figure of the inner surface of the HERO mirror shells for diameters as small as 76 mm. Mirror alignment method and sources for systematic errors will be discussed. Comparison of figure metrology of the mandrel and the shells will be presented together with results from x-ray tests.

Gubarev, Mikhail↗

AM03-AM121-115 Hard X-Ray Optics Development at MSFC

We have developed the electroformed-nickel replication process to enable us to fabricate light-weight hard-x-ray region. Two projects currently utilizing this technology are the production of over 250 r from 5 to 10 cm, for our HERO balloon payload, and 15- and 23-cm-diameter shells for a prototype module. The challenge for the former is to fabricate, mount, align and fly a large number of high-r constraints of a modest budget. For the latter, the challenge is to maintain high angular resolution shell thicknesses (100 micron) which make the shells extremely sensitive to electroforming stresses process does not degrade the ultra-smooth surface finish (approx. 3 A required for eventual multilayer c on these two programs.

Ramsey, Brian↗

Gas Scintillation Proportional Counters for High-Energy X-ray Astronomy

A focal plane array of high-pressure gas scintillation proportional counters (GSPC) for a balloon-borne hard-x-ray telescope is under development at the Marshall Space Flight Center. These detectors have an active area of approx. 20 sq cm, and are filled with a high pressure (10(exp 6) Pa) xenon-helium mixture. Imaging is via crossed-grid position-sensitive phototubes sensitive in the UV region. The performance of the GSPC is well matched to that of the telescopes x-ray optics which have response to 75 keV and a focal spot size of approx. 500 microns. The detector s energy resolution, 4% FWHM at 60 keV, is adequate for resolving the broad spectral lines of astrophysical importance and for accurate continuum measurements. Full details of the instrument and its performance will be provided.

Gubarev, Mikhail↗

Characterization of Pixelated Cadmium-Zinc-Telluride Detectors for Astrophysical Applications

Comparisons of charge sharing and charge loss measurements between two pixelated Cadmium-Zinc-Telluride (CdZnTe) detectors are discussed. These properties along with the detector geometry help to define the limiting energy resolution and spatial resolution of the detector in question. The first detector consists of a 1-mm-thick piece of CdZnTe sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). Signal readout is via discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). This crystal is bonded to a custom-built readout chip (ASIC) providing all front-end electronics to each of the 256 independent pixels. These detectors act as precursors to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation.

Gaskin, Jessica↗

Characterization of a 2-mm thick, 16x16 Cadmium-Zinc-Telluride Pixel Array

The detector under study is a 2-mm-thick, 16x16 Cadmium-Zinc-Telluride pixel array with a pixel pitch of 300 microns and inter-pixel gap of 50 microns. This detector is a precursor to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation. In addition, we discuss electric field modeling for this specific detector geometry and the role this mapping will play in terms of charge sharing and charge loss in the detector.

Gaskin, Jessica↗

Electrodeposition of High Quality Nickel Phosphorous Alloys for Pollution Reduction and Energy Conservation

NASA and the University of Alabama in Huntsville have developed ecologically friendly, versatile nickel and nickel cobalt phosphorous electroplating processes. Solutions show excellent performance with high efficiency for vastly extended throughput. Properties include, clean, low temperature operation (40 - 60 C), high Faradaic efficiency, low stress and high hardness. A variety of alloy and plating speed options are easily achieved from the same chemistry using soluble anodes for metal replacement with only 25% of the phosphorous additions required for electroless nickel. Thick deposits are easily achieved unattended, for electroforming freestanding shapes without buildup of excess orthophosphate or stripping of equipment.

Engelhaupt, Darell↗

A Novel Method for Electroplating Ultra-High-Strength Glassy Metals

A novel method for electroplating ultra-high-strength glassy metals, nickel-phosphorous and nickel-cobalt-phosphorous, has been developed at NASA Marshall Space Flight Center, cooperatively with the University of Alabama in Huntsville. Traditionally, thin coatings of these metals are achieved via electroless deposition. Benefits of the new electrolytic process include thick, low-stress deposits, free standing shapes, lower plating temperature, low maintenance, and safer operation with substantially lower cost.

Ramsey, Brian↗

Electrodeposition of Low Stress Nickel Phosphorous Alloys for Precision Component Fabrication

Nickel alloys are favored for electroforming precision components. Nickel phosphorous and nickel cobalt phosphorous are studied in this work. A completely new and innovative electrolytic process eliminates the fumes present in electroless processes and is suitable for electroforming nickel phosphorous and nickel cobalt phosphorous alloys to any desirable thickness, using soluble anodes, without stripping of tanks. Solutions show excellent performance for extended throughput. Properties include, cleaner low temperature operation (40 - 45 C), high Faradaic efficiency, low stress, Rockwell C 52 - 54 hardness and as much as 2000 N per square millimeter tensile strength. Performance is compared to nickel and nickel cobalt electroforming.

Engelhaupt, Darell↗

Instrument Development for X-Ray Astronomy

Current x-ray observatories such as Chandra and XMM-Newton have delivered spectacular results at soft-x-ray energies thanks to their grazing incidence mirrors. To continue these advances necessitates the development of mirrors with even larger collecting areas, yet within manageable weights and budgets, and focal detectors with improved energy resolution. At higher energies where x-ray critical-grazing angles become very small, x-ray optics have typically not been employed and thus this region remains relatively unexplored at high sensitivity levels and fine angular resolutions. This situation is changing with the development of hard-x-ray optics carried aloft by high-altitude balloons, which promise to bring about dramatic advances. This presentation will review developments in all these areas.

Ramsey, Brian↗

Studies of Light and Charge Produced by Alpha-Particles in High-Pressure Xenon

The results of measurements of scintillation light induced by alpha-particles in high-pressure Xe are presented. The ratio of N(sub ex)/N(sub i) and the intensity and time characteristics of the luminescence signal have been measured for different densities up to 0.74 g/cc. The role and mechanisms of the electron-ion recombination in high-pressure gas have been investigated. The existence of clusters and self-trapped excitons above 0.6 g/cc has been observed and discussed. This work is a part of a development program of high-pressure Xe detectors for low-energy gamma rays.

Bolotnikov, Aleksey↗

Design of a Day/Night Star Camera System

This paper describes the design of a camera system capable of acquiring stars during both the day and night cycles of a high altitude balloon flight (35-42 km). The camera system will be filtered to operate in the R band (590-810 nm). Simulations have been run using MODTRAN atmospheric code to determine the worse case sky brightness at 35 km. With a daytime sky brightness of 2(exp -05) W/sq cm/str/um in the R band, the sensitivity of the camera system will allow acquisition of at least 1-2 stars/sq degree at star magnitude limits of 8.25-9.00. The system will have an F2.8, 64.3 mm diameter lens and a 1340X1037 CCD array digitized to 12 bits. The CCD array is comprised of 6.8 X 6.8 micron pixels with a well depth of 45,000 electrons and a quantum efficiency of 0.525 at 700 nm. The camera's field of view will be 6.33 sq degree and provide attitude knowledge to 8 arcsec or better. A test flight of the system is scheduled for fall 1999.

Alexander, Cheryl↗

Evaluation of Chemical Coating Processes for AXAF

The need existed at MSFC for the development and fabrication of radioisotope calibration sources of cadmium 109 and iron 55 isotopes. This was in urgent response to the AXA-F program. Several issues persisted in creating manufacturing difficulties for the supplier. In order to meet the MSFC requirements very stringent control needed to be maintained for the coating quality, specific activity and thickness. Due to the difficulties in providing the precisely controlled devices for testing, the delivery of the sources was seriously delayed. It became imperative that these fabrication issues be resolved to avoid further delays in this AXA-F observatory key component. The objectives are: 1) Research and provide expert advice on coating materials and procedures. 2) Research and recommend solutions to problems that have been experienced with the coating process. 3) Provide recommendations on the selection and preparation of substrates. 4) Provide consultation on the actual coating process including the results of the qualification and acceptance test programs. 5) Perform independent tests at UAH or MSFC as necessary.

Engelhaupt, Darell↗