Search NASA⌕ Search

Engineering topics

Ranga Narayanan

Publications and source records attributed to Ranga Narayanan.

Characterization of Oscillation Modes in Levitated Droplets Using Image and Non-Image Based Techniques

The dynamics of levitated liquid droplets can be used to measure their thermophysical properties by correlating the frequencies at which normal modes of oscillation most strongly resonate when subject to an external oscillatory force. In two preliminary works, it was shown via electrostatic levitation and processing of various metals and alloys that 1) the resonance of the first principal mode of oscillation (mode n = 2) can be used to accurately measure surface tension and 2) that so-called ‘higher-order resonance’ of n = 3 is observable at a predictable frequency. It was also shown, in the context of future space-based experimentation on the Electrostatic Levitation Furnace (ELF), a setup on the International Space Station (ISS) operated by Japan Aerospace Exploration Agency (JAXA), that while the shadow array method in which droplet behavior is visualized would be challenging to identify the n = 3 resonance, the normal mode n = 4 was predicted to be more easily identifiable. In this short communication, experimental evidence of the first three principal modes of oscillation is provided using molten samples of Tin and Indium and it is subsequently shown that, as predicted, an “image-less” approach can be used to identify both n = 2 and n = 4 resonances in levitated liquid droplets. This suggests that the shadow array method may be satisfactorily used to obtain a self-consistent benchmark of thermophysical properties by comparing results from two successive even-mode natural frequencies.

Nevin Brosius↗

Research Campaign: Advanced Manufacturing in Space: Properties, Structure and Simulations to Pioneer New Applications

This topic underpins synthesis of, and in many cases manufacturing of, value-added materials via liquid phase processing. Materials and processes range from cast metals and optical glasses through exploration-relevant technologies such as additive manufacturing, casting and in-situ resource utilization to support human space exploration. A recurring theme is the need for accurate thermophysical property and atomic structure data for relevant materials and the exploitation of reduced convection/sedimentation in microgravity to enhance the quality of data and to develop new and transformative technologies for materials processing.

Michael SanSoucie↗

Topical: Boiling, Condensation and Two-Phase Flows in Microgravity

The white paper addresses both fundamental and technological questions in the science of phase-change fluid flows aimed at understanding thermal transport in flow boiling and condensation and the use of these processes in space and terrestrial thermal systems. While flow boiling and condensation are widely employed in Earth-based thermal equipment to reduce the cost, size, and power required to transfer heat, a lack of data and predictive models on the impact of gravity on these phenomena hinders the use of two-phase heat transport in a low-gravity environment. The white paper presents research tasks in long-duration microgravity recommended to expand our knowledge on phase-changing flows. Due to elimination of the masking gravity effects, the proposed research will provide a unique opportunity to bring new insights into the role of capillary and hydrodynamic forces in phase-changing flows. The potential impact of the proposed research ranges from the space power, thermal and cryogenic systems to various terrestrial applications in the petrochemical, pharmaceutical, biochemical, nuclear, and metallurgical industries.

Phase-change fluid flow↗

Benchmarking Surface Tension Measurement Method using two Oscillation Modes in Levitated Liquid Metals

The Faraday forcing method in levitated liquid droplets has recently been introduced as a method for measuring surface tension using resonance. By subjecting an electrostatically-levitated liquid metal droplet to a continuous, oscillatory, electric field, at a frequency nearing that of the droplet’s first principal mode of oscillation (known as mode 2), the method was previously shown to determine surface tension of materials that would be particularly difficult to process by other means, e.g. liquid metals and alloys. It also offers distinct advantages in future work involving high viscosity samples because of the continuous forcing approach. This work presents 1) a benchmarking experimental method to measure surface tension by excitation of the second principal mode of oscillation (known as mode 3) in a levitated liquid droplet and 2) a more rigorous quantification of droplet excitation using a projection method. Surface tension measurements compare favorably to literature values for Zirconium, Inconel 625, and Rhodium, using both modes 2 and 3. Thus, this new method serves as a credible, self-consistent benchmarking technique for the measurement of surface tension

Levitation↗

Faraday Forcing of High-Temperature Levitated Liquid Metal Drops for the Measurement of Surface Tension

In this work, a method for the measurement of surface tension using continuous periodic forcing is presented. To reduce gravitational effects, samples are electrostatically levitated prior to forcing. The method, called Faraday forcing, is particularly well suited for fluids that require high temperature measurements such as liquid metals where conventional surface tension measurement methods are not possible. It offers distinct advantages over the conventional pulse-decay analysis method when the sample viscosity is high or the levitation feedback control system is noisy. In the current method, levitated drops are continuously translated about a mean position at a small, constant forcing amplitude over a range of frequencies. At a particular frequency in this range, the drop suddenly enters a state of resonance, which is confirmed by large executions of prolate/oblate deformations about the mean spherical shape. The arrival at this resonant condition is a signature that the parametric forcing frequency is equal to the drop’s natural frequency, the latter being a known function of surface tension. A description of the experimental procedure is presented. A proof of concept is given using pure Zr and a Ti(sub 39.5)Zr(sub 39.5)Ni(sub 21) alloy as examples. The results compare favorably with accepted literature values obtained using the pulse-decay method.

Nevin Brosius↗