High-intensity polarized and unpolarized H- sources development and operational at BNL
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Raparia, D..
Explore the source record for details and available documents.
The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.
The Beam Energy Scan phase II (BES-II), performed in the Relativistic Heavy Ion Collider (RHIC) from 2019 to 2021, explored the phase transition between quark-gluon plasma and hadronic gas. BES-II exceeded the goal of a fourfold increase in the average luminosity over that achieved during Beam Energy Scan phase I (BES-I), at five gold beam energies: 9.8, 7.3, 5.75, 4.59, and 3.85 GeV / nucleon. This was accomplished by addressing several beam dynamics effects, including intrabeam scattering, beam-beam, space charge, beam instability, and field errors induced by superconducting magnet persistent currents. Some of these effects are especially detrimental at low energies. BES-II achievements are presented, and the measures taken to improve RHIC performance are described. These measures span the whole RHIC complex, including ion beam sources, injectors, beam lifetime improvements in RHIC, and operation with the world’s first bunched beam Low Energy RHIC electron Cooler (LEReC).
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
RHIC will provide Au-Au collisions at beam energies of 5.75, 4.59 GeV/nucleon for physics program in 2020, and at beam energy of 3.85 GeV/nucleon for physics program in 2021 as part of the BeamEnergy Scan II (BES-II). The oper- ational experience gained in the first year (2019) of BES-II operation will be applied toward operations in the coming years. This article will present some technical details and the outlook of the BES-II operations in the coming years.
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of 10−29 e ⋅ cm by using polarized “magic” momentum 0.7 GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the standard model at the scale of 3000 TeV.
A beam energy scan of deuteron-gold collision, with center-of-mass energy at 19.6, 39, 62.4 and 200.7 GeV/n, was performed at the Relativistic Heavy Ion Collider in 2016 to study the threshold for quark-gluon plasma (QGP) production. The lattice, RF, stochastic cooling and other subsystems were in different configurations for the various energies. The operational challenges changed with every new energy. The operational experience at each energy, the operation performance, highlights and lessons of the beam energy scan are reviewed in this report.