Search NASASearch

Engineering topics

Rashidnia, Nasser

Publications and source records attributed to Rashidnia, Nasser.

Novel Optical Diagnostic Techniques for Studying Particle Contact and Deposition Upon a Large Cylinder in a Sheared Suspension

The objectives of this research project were: 1) To study the fluid dynamics of sheared particle-liquid suspensions and the impact of differential particle-fluid inertia; 2) To develop new techniques for observing suspension particle contact and deposition upon solid surfaces. Dr. Yoda was supported by the NASA Office of Biological and Physical Research on a four-year grant from March 2000 through November 2004 for a ground-based study on the fluid dynamics of sheared particle-liquid suspensions and the impact of differential particle-fluid inertia on such flows. Such inertial effects can only be observed in reduced-gravity environments since they are overwhelmed by buoyancy effects on Earth. Moreover, these inertial effects will have a significant impact upon suspension flows in microgravity. Suspension dynamics are of importance in a wide variety of advanced life systems applications, including water reclamation and dust mitigation in confined habitats.

Rashidnia, Nasser

Measuring Diffusion of Liquids by Common-Path Interferometry

A method of observing the interdiffusion of a pair of miscible liquids is based on the use of a common-path interferometer (CPI) to measure the spatially varying gradient of the index refraction in the interfacial region in which the interdiffusion takes place. Assuming that the indices of refraction of the two liquids are different and that the gradient of the index of refraction of the liquid is proportional to the gradient in the relative concentrations of either liquid, the diffusivity of the pair of liquids can be calculated from the temporal variation of the spatial variation of the index of refraction. This method yields robust measurements and does not require precise knowledge of the indices of refraction of the pure liquids. Moreover, the CPI instrumentation is compact and is optomechanically robust by virtue of its common- path design. The two liquids are placed in a transparent rectangular parallelepiped test cell. Initially, the interface between the liquids is a horizontal plane, above which lies pure liquid 2 (the less-dense liquid) and below which lies pure liquid 1 (the denser liquid). The subsequent interdiffusion of the liquids gives rise to a gradient of concentration and a corresponding gradient of the index of refraction in a mixing layer. For the purpose of observing the interdiffusion, the test cell is placed in the test section of the CPI, in which a collimated, polarized beam of light from a low-power laser is projected horizontally through a region that contains the mixing layer.

Rashidnia, Nasser

Diffusivity Measured as a Function of Concentration

Optical diagnostic techniques have become an integral part of many measurements in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used to measure optical wave fronts for lens testing and combustion and fluid flow diagnostics. One such instrument is the point diffraction interferometer (PDI), which is considered to be robust because it has a common-path design. However, the PDI is difficult to align and has limited measurement range for liquid phase applications. Interferometry and schlieren techniques have been widely used for many years for gas flow visualization.

Rashidnia, Nasser

Novel Diffusivity Measurement Technique

A common-path interferometer (CPI) system was developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. This system uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. Hence, the molecular diffusion coefficient of liquids can be determined using the physical relations between changes in the optical path length and the liquid phase properties. The data obtained with this interferometer were compared with similar results from other techniques and demonstrated that the instrument is superior in measuring the diffusivity of miscible liquids while keeping the system very compact and robust. CPI can also be used for studies in interface dynamics and other diffusion-dominated-process applications.

Rashidnia, Nasser

Novel Shapes of Miscible Interfaces Observed

The dynamics of miscible displacements in a cylindrical tube are being investigated experimentally and numerically, with a view to understand the complex processes that occur, for example, in enhanced oil recovery, hydrology, and filtration. We have observed complex shapes of the interface between two liquids that mix with each other when the less viscous liquid is displaced by the more viscous one in a tube. A less viscous fluid that displaces a more viscous fluid is known to propagate in the form of a "finger," and a flight experiment proposed by Maxworthy et al. to investigate the miscible-interface dynamics is currently being developed by NASA. From the current theory of miscible displacements, which was developed for a porous medium satisfying Darcy's law, it can be shown that in the absence of gravity the interface between the fluids is destabilized and thus susceptible to fingering only when a more viscous fluid is displaced by a less viscous one. Therefore, if the interface is initially flat and the more viscous fluid displaces the less viscous fluid, the interface ought to be stable and remain flat. However, numerical simulations by Chen and Meiburg for such displacement in a cylindrical tube show that the interface is unstable and a finger of the more viscous fluid is indeed formed. Preliminary experiments performed at the NASA Glenn Research Center show that not only can fingering occur when the more viscous fluid displaces a less viscous one in a cylindrical tube, but also that under certain conditions the advancing finger achieves a sinuous or snakelike shape. These experiments were performed using silicone oils in a vertical pipette of small diameter. In the initial configuration, the more viscous fluid rested on top of the less viscous one, and the interface was nominally flat. A dye was added to the upper liquid for ease of observation of the interface between the fluids. The flow was initiated by draining the lower fluid from the bottom of the pipette, at speeds less than 0.1 mm/sec.

Balasubramaniam, Ramaswamy

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser

Bubble Dynamics on a Heated Surface

In this work, we study the combined thermocapillary and natural convective flow generated by a bubble on a heated solid surface. The interaction between gas and vapor bubbles with the surrounding fluid is of interest for both space and ground-based processing. On earth, the volumetric forces are dominant, especially, in apparatuses with large volume to surface ratio. But in the reduced gravity environment of orbiting spacecraft, surface forces become more important and the effects of Marangoni convection are easily unmasked. In order to delineate the roles of the various interacting phenomena, a combined numerical-experimental approach is adopted. The temperature field is visualized using Mach-Zehnder interferometry and the flow field is observed by a laser sheet flow visualization technique. A finite element numerical model is developed which solves the two-dimensional momentum and energy equations and includes the effects of bubble surface deformation. Steady state temperature and velocity fields predicted by the finite element model are in excellent qualitative agreement with the experimental results. A parametric study of the interaction between Marangoni and natural convective flows including conditions pertinent to microgravity space experiments is presented. Numerical simulations clearly indicate that there is a considerable difference between 1-g and low-g temperature and flow fields induced by the bubble.

Kassemi, Mohammad

Robust Quantitative Measurement of Flows and Transparent or Highly Reflective Objects

The liquid crystal point diffraction interferometer (LCPDI) is a new instrument that has been developed for the measurement of phase objects. The LCPDI uses the compact, robust design of Linnik's point diffraction interferometer and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wave-fronts. A solid state camera provides very high data density and automated data reduction. The instrument can measure either transparent objects like fluids and lenses, or highly reflective opaque objects like mirrors. In the former case, the refractive index distribution is measured and then related to various properties like temperature, density, chemical composition, or thickness. In the latter case, the measured phase distribution is related to the object shape. The objects measured must be stationary or quasisteady state because the measurement requires the acquisition of several frames of image data during which time the object's properties must not have changed. The data acquisition time depends on the speed of the frame grabber and the required number of data frames. Typically, three to five frames taking 1 to 2 seconds are required. The potential for faster data acquisition exists.

Mercer, Carolyn R.

More About Measuring Interfacial Tension Between Liquids

Report presents additional discussion of technique for measuring interfacial tension between two immiscible liquids. Technique described in "Measuring Interfacial Tension Between Immiscible Liquids" (LEW-15855).

Rashidnia, Nasser

A phase-stepped point diffraction interferometer using liquid crystals

A new instrument, the liquid crystal point diffraction interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with high data density and with automated data reduction. The design of the LCPDI is briefly discussed. An algorithm is presented for eliminating phase measurement error caused by object beam intensity variation from frame-to-frame. The LCPDI is demonstrated by measuring the temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to independently measured results and show excellent agreement with them. It is expected that this instrument will have application in the fluid sciences as a diagnostic tool, particularly in space based applications where autonomy, robustness, and compactness are desirable qualities. It should also be useful for the testing of optical elements, provided a master is available for comparison.

Mercer, Carolyn R.

Measuring Interfacial Tension Between Immiscible Liquids

Glass capillary tube technique measures interfacial tension between two immiscible liquids. Yields useful data over fairly wide range of interfacial tensions, both for pairs of liquids having equal densities and pairs of liquids having unequal densities. Data on interfacial tensions important in diverse industrial chemical applications, including enhanced extraction of oil; printing; processing foods; and manufacture of paper, emulsions, foams, aerosols, detergents, gel encapsulants, coating materials, fertilizers, pesticides, and cosmetics.

Rashidnia, Nasser

High data density temperature measurement for quasi steady-state flows

A new optical instrument, the liquid crystal point diffraction interferometer (LCPDI), is used to measure the temperature distribution across a heated chamber filled with silicone oil. Data taken using the LCPDI are compared to equivalent measurements made with a traversing thermocouple and the two data sets show excellent agreement This instrument maintains the compact, robust design of Linnik's point diffraction interferometer and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with very high data density and with automated data reduction.

Mercer, Carolyn R.

Transport phenomena in stratified multi-fluid flo w in the presence and absence of gravity

An experiment is being conducted to study the effects of buoyancy on planar stratified flows. A wind tunnel has been designed and constructed to generate planar flows with separate heating for the top and bottom planar air jets emerging from slot nozzles separated by an insulating splitter plate. The objective is to generate planar jet flows with well defined and well controlled velocity and temperature profiles. Magnitudes of velocity and temperature will be varied separately in each flow for both laminar and turbulent flow conditions. Both stably and unstably stratified flows will be studied by changing the temperature distributions in each air stream. This paper reports on the design of the apparatus and initial measurements of velocity and turbulence made by laser Doppler velocimetry.

Chigier, Norman

Numerical studies of convective heat transfer in an inclined semiannular enclosure

Natural convection heat transfer in a two-dimensional differentially heated semiannular enclosure is studied. The enclosure is isothermally heated and cooled at the inner and outer walls, respectively. A commercial software based on the SIMPLER algorithm was used to simulate the velocity and temperature profiles. Various parameters that affect the momentum and heat transfer processes were examined. These parameters include the Rayleigh number, Prandtl number, radius ratio, and the angle of inclination. A flow regime extending from conduction-dominated to convection-dominated flow was examined. The computed results of heat transfer are presented as a function of flow parameter and geometric factors. It is found that the heat transfer rate attains a minimum when the enclosure is tilted about +50 deg with respect to the gravitational direction.

Wang, Lin-Wen