Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility of using thermal response methods for nonintrusive compressed air flow measurement

Robust, low-cost nonintrusive flow meters are of interest in many industries. Particularly, a reliable nonintrusive flow measurement for the diagnosis of air leaks in compressed air systems is desirable. Measurement of the air flow due to leaks in the system ensures an accurate estimation of potential cost and energy savings. This study evaluates a novel method of using thermal responses to nonintrusively measure leakage rates in compressed air lines. The method uses heat and the resulting thermal response to calculate the flow rate inside the compressed air line. Compared to the current methods for flow measurement, this method can simplify flow measurement while decreasing the sensitivity to errors when measuring flow rates. In this study, the methodology of the proposed method is explained along with the potential advantages to the design. Two approaches are evaluated: a dynamic step response and sinusoidal frequency response. Simulated tests evaluate the feasibility of the proposed methods, followed by experiments that validate the simulation results. A clear correlation between the thermal step response and the flow rate indicate viability of the proposed method in simulation. Experimental results yielded similar results, confirming the validity of the proposed method. The results of a field test in an industrial environment demonstrate the capability of the approach to other flow rate measurement techniques.

42 ENGINEERING↗