Search NASA⌕ Search

Engineering topics

Ratti, A

Publications and source records attributed to Ratti, A.

Operational results from the LHC luminosity monitors

The luminosity monitors for the high luminosity regions in the LHC have been operating to monitor and optimize the luminosity since 2009. The device is a gas ionization chamber inside the neutral particle absorber 140 m from the interaction point and monitors showers produced by high energy neutral particles from the collisions. It has the ability to resolve the bunch-by-bunch luminosity as well as to survive the extreme level of radiation in the nominal LHC operation. We present operational results of the device during proton and lead ion operations in 2010 and make comparisons with measurements of experiments. The Large Hadron Collider (LHC) at CERN can accelerate proton and lead ion beams to 7 TeV and 547 TeV and produce collisions of these particles. Luminosity measures performance of the LHC and is particularly important for experiments in high luminosity interaction points (IPs), ATLAS (IP1) and CMS (IP5). To monitor and optimize the luminosities of these IPs, BRAN (Beam RAte Neutral) detectors [1, 2] have been installed and operating since the beginning of the 2009 operation [3]. A neutral particle absorber (TAN) protects the D2 separation dipole from high energy forward neutral particles produced in the collisions [4]. These neutral particles produce electromagnetic and hadronic showers inside the TAN and their energy flux is proportional to the collision rate and hence to the luminosity. The BRAN detector is an Argon gas ionization chamber installed inside the TANs on both sides of the IP1 and IP5 and monitors the relative changes in the luminosity by detecting the ionization due to these showers. When the number of collisions per bunch crossing (multiplicity) is small, the shower rate inside the TAN is also proportional to the luminosity. Hence, the detector is designed to operate by measuring either the shower rate (counting mode for low and intermediate luminosities) or the average shower flux (pulse height mode for high luminosities). The detector is also designed (1) to survive the extreme level of radiation ({approx}1 GGy in the nominal condition), (2) to resolve the shower from each bunch crossing (40 MHz in the nominal condition) and measure the bunch-by-bunch luminosities, and (3) to have four independent square shaped channels, each occupying a quadrant, making the detector sensitive to the crossing angle [1, 2]. During the proton operation in 2010, the beam energy was 3.5 TeV and the multiplicity did not exceed four. Because the counting mode is still effective in such a condition [5], the BRAN were operated in the counting mode in 2010. This paper presents operational results of the BRANs during the operation in 2010 (mainly the proton operation) and makes comparisons with measurements of the experiments. The luminosity optimization is discussed in detail in [6] and so this paper focuses on measurements during the normal operation.

43 PARTICLE ACCELERATORS↗

Simulations of the LHC high luminosity monitors at beam energies from 3.5 TeV to 7.0 TeV

We have constructed two pairs of fast ionization chambers (BRAN) for measurement and optimization of luminosity at IR1 and IR5 of the LHC. These devices are capable of monitoring the performance of the LHC at low luminosity 10{sup 28} cm{sup -2}s{sup -1} during beam commissioning all the way up to the expected full luminosity of 10{sup 34} cm{sup -2}s{sup -1} at 7.0 TeV. The ionization chambers measure the intensity of hadronic/electromagnetic showers produced by the forward neutral particles of LHC collisions. To predict and improve the understanding of the BRAN performance, we created a detailed FLUKA model of the detector and its surroundings. In this paper, we describe the model and the results of our simulations including the detector's estimated response to pp collisions at beam energies of 3.5, 5.0, and 7.0 TeV per beam. In addition, these simulations show the sensitivity of the BRAN to the crossing angle of the two LHC beams. It is shown that the BRAN sensitivity to the crossing angle is proportional to the measurement of crossing angle by the LHC beam position monitors.

43 PARTICLE ACCELERATORS↗

A Next Generation Light Source Facility at LBNL

The Next Generation Light Source (NGLS) is a design concept, under development at LBNL, for a multibeamline soft x-ray FEL array powered by a ~;;2 GeV superconducting linear accelerator, operating with a 1 MHz bunch repetition rate. The CW superconducting linear accelerator is supplied by a high-brightness, highrepetition- rate photocathode electron gun. Electron bunches are distributed from the linac to the array of independently configurable FEL beamlines with nominal bunch rates up to 100 kHz in each FEL, and with even pulse spacing. Individual FELs may be configured for EEHG, HGHG, SASE, or oscillator mode of operation, and will produce high peak and average brightness x-rays with a flexible pulse format, with pulse durations ranging from sub-femtoseconds to hundreds of femtoseconds.

43 PARTICLE ACCELERATORS↗

Simulation of the LHC BRAN luminosity monitor for high luminosity interaction regions

The BRAN (Beam RAte of Neutrals) detector monitors the collision rates in the high luminosity interaction regions of LHC (ATLAS and CMS). This Argon gas ionization detector measures the forward neutral particles from collisions at the interaction point. To predict and improve the understanding of the detector's performance, we produced a detailed model of the detector and its surroundings in Fluka. In this paper, we present the model and results of our simulations including the detectors estimated response to interactions for beam energies of 3.5, 5, and 7 TeV.

43 PARTICLE ACCELERATORS↗

Hand-held UXO Discriminator

With prior funding (UX-1225, MM-0437, and MM-0838), we have successfully designed and built a cart-mounted Berkeley UXO Discriminator (BUD) and demonstrated its performance at various test sites (e.g., Gasperikova et al., 2007, 2009). It is a multi-transmitter multi-receiver active electromagnetic system that is able to discriminate UXO from scrap at a single measurement position, hence eliminates equirement of a very accurate sensor location. The cart-mounted system comprises of three orthogonal transmitters and eight pairs of differenced receivers (Smith et al., 2007). Receiver coils are located on ymmetry lines through the center of the system and see identical fields during the on-time of the pulse in all of the transmitter coils. They can then be wired in opposition to produce zero output during the n-ime of the pulses in three orthogonal transmitters. Moreover, this configuration dramatically reduces noise in the measurements by canceling the background electromagnetic fields (these fields are uniform ver the scale of the receiver array and are consequently nulled by the differencing operation), and by canceling the noise contributed by the tilt of the receivers in the Earth's magnetic field, and therefore reatly enhances receivers sensitivity to the gradients of the target.

54 ENVIRONMENTAL SCIENCES↗

The Luminosity Monitoring System for the LHC: Modeling and Test Results

Simulation results of the Beam Rate of Neutrals (BRAN) luminosity detector for the CERN Large Hadron Collider are presented. The detectors are intended to measure the bunch-by-bunch relative luminosity at the ATLAS and CMS experiments. Building up from experimental results from test runs at the SPS, RHIC and ALS we extend the simulated setup to the TAN neutral absorbers located at 140 m at both sides the IP1 and IP5 interaction points. The expected signal amplitudes are calculated for pp-collisions energies between 450 GeV and 7 TeV using the Monte Carlo package FLUKA and its graphical user interface FLAIR.

43 PARTICLE ACCELERATORS↗

Test Results of the Luminosity Monitors for the LHC

The Luminosity Monitor for the LHC has been built at LBNL and will be operational in the LHC during the upcoming run. The device, a gas ionization chamber, is installed in the high luminosity regions (those dedicated to the ATLAS and CMS experiments) and capable to resolve bunch-by-bunch luminosity as well as survive extreme levels of radiation. During the experimental R&D phase of its design, a prototype of this detector has been tested extensively at the ALS, in RHIC as well as in the SPS. Results of these experiments are presented here.

43 PARTICLE ACCELERATORS↗

Use of High Resolution DAQ System to Aid Diagnosis of HD2b, a High Performance Nb3Sn Dipole

A novel voltage monitoring system to record voltage transients in superconducting magnets is being developed at LBNL. This system has 160 monitoring channels capable of measuring differential voltages of up to 1.5kV with 100kHz bandwidth and 500kS/s digitizing rate. This paper presents analysis results from data taken with a 16 channel prototype system. From that analysis we were able to diagnose a change in the current-temperature margin of the superconducting cable by analyzing Flux-Jump data collected after a magnet energy extraction failure during testing of a high field Nb{sub 3}Sn dipole.

43 PARTICLE ACCELERATORS↗