Search NASASearch

Engineering topics

Rauh, R. David

Publications and source records attributed to Rauh, R. David.

Electrochemical Detection of Multiple Bioprocess Analytes

An apparatus that includes highly miniaturized thin-film electrochemical sensor array has been demonstrated as a prototype of instruments for simultaneous detection of multiple substances of interest (analytes) and measurement of acidity or alkalinity in bioprocess streams. Measurements of pH and of concentrations of nutrients and wastes in cell-culture media, made by use of these instruments, are to be used as feedback for optimizing the growth of cells or the production of desired substances by the cultured cells. The apparatus is designed to utilize samples of minimal volume so as to minimize any perturbation of monitored processes. The apparatus can function in a potentiometric mode (for measuring pH), an amperometric mode (detecting analytes via oxidation/reduction reactions), or both. The sensor array is planar and includes multiple thin-film microelectrodes covered with hydrous iridium oxide. The oxide layer on each electrode serves as both a protective and electrochemical transducing layer. In its transducing role, the oxide provides electrical conductivity for amperometric measurement or pH response for potentiometric measurement. The oxide on an electrode can also serve as a matrix for one or more enzymes that render the electrode sensitive to a specific analyte. In addition to transducing electrodes, the array includes electrodes for potential control. The array can be fabricated by techniques familiar to the microelectronics industry. The sensor array is housed in a thin-film liquid-flow cell that has a total volume of about 100 mL. The flow cell is connected to a computer-controlled subsystem that periodically draws samples from the bioprocess stream to be monitored. Before entering the cell, each 100-mL sample is subjected to tangential-flow filtration to remove particles. In the present version of the apparatus, the electrodes are operated under control by a potentiostat and are used to simultaneously measure the pH and the concentration of glucose. It is anticipated that development of procedures for trapping more enzymes into hydrous iridium oxide (and possibly into other electroactive metal oxides) and of means for imparting long-term stability to the transducer layers should make it possible to monitor concentrations of products of many enzyme reactions for example, such key bioprocess analytes as amino acids, vitamins, lactose, and acetate.

Rauh, R. David

Photopolymerized Electrolytes For Electrochromic Devices

Thin ion-conducting electrolyte films for use in electrochromic devices now fabricated relatively easily and quickly with any of class of improved formulations containing ultraviolet-polymerizable components. Formulations are liquids in their monomeric forms and self-supporting, transparent solids in their polymeric forms. Thin solid electrolytes form quickly and easily between electrode-bearing substrates. Film thus polymerized acts not only as solid electrolyte but also as glue holding laminate together: feature simplifies fabrication by reducing need for sealants and additional mechanical supports.

Cogan, Stuart

Photoelectrochemical fabrication of spectroscopic diffraction gratings, phase 2

This program was directed toward the production of Echelle diffraction gratings by a light-driven, electrochemical etching technique (photoelectrochemical etching). Etching is carried out in single crystal materials, and the differential rate of etching of the different crystallographic planes used to define the groove profiles. Etching of V-groove profiles was first discovered by us during the first phase of this project, which was initially conceived as a general exploration of photoelectrochemical etching techniques for grating fabrication. This highly controllable V-groove etching process was considered to be of high significance for producing low pitch Echelles, and provided the basis for a more extensive Phase 2 investigation.

Rauh, R. David

Chemical sensor

A sensor for detecting a chemical substance includes an insertion element having a structure which enables insertion of the chemical substance with a resulting change in the bulk electrical characteristics of the insertion element under conditions sufficient to permit effective insertion; the change in the bulk electrical characteristics of the insertion element is detected as an indication of the presence of the chemical substance.

Rauh, R. David

Electrochromic Variable-Emissivity Surfaces

Temperature controlled by altering infrared radiative properties. Infrared emissivity of electrochromically active layer changed by applying voltage to insert or remove Li atoms electrochemically. Change reversible and continuously variable between specified limits of layered structure.

Rauh, R. David

Photoelectrochemical fabrication of sawtooth gratings in n-GaAs

A photoelectrochemical approach is employed to fabricate exceptionally smooth low-pitch grating structures consisting of polished single crystals of (100) oriented n-GaAs in a sawtooth profile. The depth of the edged features is controlled by monitoring the total coulombs passed, and the rate of etching is precisely controlled by the light intensity, minimizing diffusional gradients in the liquid which may impair the uniformity. Symmetrical grooves spaced 10 microns apart will have a depth of 7.14 microns, and typically, 10-20 percent less total charge is required.

Carrabba, Michael M.

Photoelectrochemical fabrication of spectroscopic diffraction gratings

Photoelectrochemical etching was demonstrated as a means of fabricating a variety of periodic structures in semiconductors. The semiconductor is used as an electrode in an electrochemical cell, and is in contact with a liquid electrolyte. When the crystal is held at a positive voltage and illuminated, etching occurs in only the illuminated regions to a depth proportional to the illumination intensity and exposure time. In Phase 1, it was determined that diffraction gratings could be produced in gallium arsenide crystals by this method, using either a scanned focused laser beam or by uniform illumination of a ruling mask defined in metal or photoresist on the crystal surface. The latter approach was determined to produce V-grooves if the mask is oriented along certain crystallographic directions. These V-grooves were produced with an exceedingly smooth crystal morphology due to the highly controllable nature of the process and the mild electrolytes involved. The results form the basis for photoelectrochemical fabrication of deep, low pitch Eschelle gratings for use in high orders in NASA spectrographic instrumentation such as the Space Telescope Imaging Spectrograph.

Rauh, R. David