Search NASA⌕ Search

Engineering topics

Rawat, R S

Publications and source records attributed to Rawat, R S.

Effects of laser energy fluence on the onset and growth of the Rayleigh-Taylor instabilities and its influence on the topography of the Fe thin film grown in pulsed laser deposition facility

The effect of laser energy fluence on the onset and growth of Rayleigh-Taylor (RT) instabilities in laser induced Fe plasma is investigated using time-resolved fast gated imaging. The snow plow and shock wave models are fitted to the experimental results and used to estimate the ablation parameters and the density of gas atoms that interact with the ablated species. It is observed that RT instability develops during the interface deceleration stage and grows for a considerable time for higher laser energy fluence. The effects of RT instabilities formation on the surface topography of the Fe thin films grown in pulsed laser deposition system are investigated (i) using different laser energy fluences for the same wavelength of laser radiation and (ii) using different laser wavelengths keeping the energy fluence fixed. It is concluded that the deposition achieved under turbulent condition leads to less smooth deposition surfaces with bigger sized particle agglomerates or network.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coded aperture imaging of fusion source in a plasma focus operated with pure D{sub 2} and a D{sub 2}-Kr gas admixture

The coded aperture imaging (CAI) technique has been used to investigate the spatial distribution of DD fusion in a 1.6 kJ plasma focus (PF) device operated in, alternatively, pure deuterium or deuterium-krypton admixture. The coded mask pattern is based on a singer cyclic difference set with 25% open fraction and positioned close to 90 Degree-Sign to the plasma focus axis, with CR-39 detectors used to register tracks of protons from the D(d, p)T reaction. Comparing the coded aperture imaging proton images for pure D{sub 2} and D{sub 2}-Kr admixture operation reveals clear differences in size, density, and shape between the fusion sources for these two cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the plume splitting of pulsed laser ablated Fe and Al plasmas

A time resolved imaging study of pulsed laser ablated Fe and Al plasma plumes with specific interest in the splitting of plumes into the slow and fast moving components as they expand through the background argon gas at different pressures is reported. The material ablation was achieved using a Q-switched Nd:YAG (yttrium aluminum garnet) laser operating at 532 nm with a pulse duration of {approx}8 ns full width at half maximum and a fluence of 30 Jcm{sup -2} at the target surface. Typical time resolved images with low magnification show that the splitting occurs at moderate background gas pressures (0.5 and 1.0 mbar for Fe, and 0.2 mbar for Al plasma plumes). The plume splitting did not occur for higher background gas pressures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute measurements of fast neutrons using yttrium

Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f{sub n}{approx}4.1x10{sup -4} with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10{sup 8} neutrons per discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray yield from NX2 plasma focus

The Lee model code is used to compute neon soft x-ray yield Y{sub sxr} for the NX2 plasma focus as a function of pressure. Comparison with measured Y{sub sxr} shows reasonable agreement in the Y{sub sxr} versus pressure curve, the absolute maximum yield as well as the optimum pressure. This gives confidence that the code gives a good representation of the neon plasma focus in terms of gross properties including speeds and trajectories and soft x-ray yields, despite its lack of modeling localized regions of higher densities and temperatures. Computed current curves versus pressure are presented and discussed particularly in terms of the dynamic resistance of the axial phase. Computed gross properties of the plasma focus including peak discharge current I{sub peak}, pinch current I{sub pinch}, minimum pinch radius r{sub min}, plasma density at the middle duration of pinch n{sub pinch}, and plasma temperature at middle duration of pinch T{sub pinch} are presented and the trends in variation of these are discussed to explain the peaking of Y{sub sxr} at optimum pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Backward high energy ion beams from plasma focus

High energy neutrons, more than 2.45 MeV from deuteron-deuteron fusion reaction, have been measured in backward direction of plasma focus devices in many laboratories. However the experimental evidence for high energy deuterons responsible for such neutrons has not been reported so far. In this brief communication, backward high energy deuteron beam from NX2 plasma focus [M. V. Roshan et al., Phys. Lett. A 373, 851 (2009)] is reported, which was measured with a direct and unambiguous technique of nuclear activation. The relevant nuclear reaction for the target activation is {sup 12}C(d,n){sup 13}N, which has a deuteron threshold energy of 328 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron and high energy deuteron anisotropy investigations in plasma focus device

The anisotropies of neutron and high energy deuteron emissions from the NX2 plasma focus device [M. V. Roshan et al., Phys. Lett. A 373, 851 (2009)] are studied. The nuclear activation of graphite targets is used to measure the fluences of high energy deuterons in the axial and radial directions. Two bismuth germanate scintillation detectors connected to multichannel analyzer systems are used for the detection of 511 keV gamma rays resulting from positron annihilation in the two targets. In addition, fast neutron activation detectors are employed to measure the axial and radial fluences of fusion neutrons. These detection systems are calibrated using the simulation code MCNPX[L. S. Waters et al., AIP Conf. Proc. 896, 81 (2007)]. Two distinct regimes of neutron and deuteron anisotropies are observed for the NX2 device. For deuterium gas pressures below 10 mbar, the neutron anisotropy increases with increasing pressure, while the overall neutron yield remains low. For gas pressures of 10-14 mbar, the neutron anisotropy is essentially constant, while, with increasing pressure, the neutron yield rises rapidly and the deuteron anisotropy falls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Order of magnitude enhancement in neutron emission with deuterium-krypton admixture operation in miniature plasma focus device

The effect of varied concentrations of deuterium-krypton (D{sub 2}-Kr) admixture on the neutron emission of a fast miniature plasma focus device was investigated. It was found that a judicious concentration of Kr in D{sub 2} can significantly enhance the neutron yield. The maximum average neutron yield of (1{+-}0.27)x10{sup 4} n/shot for pure D{sub 2} filling at 3 mbars was enhanced to (3.14{+-}0.4)x10{sup 5} n/shot with D{sub 2}+2% Kr admixture operation, which represents a >30-fold increase. More than an order of magnitude enhancement in the average neutron yield was observed over the broader operating range of 1-4 mbars for D{sub 2}+2% Kr and D{sub 2}+5% Kr admixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computing plasma focus pinch current from total current measurement

The total current I{sub total} waveform in a plasma focus discharge is the most commonly measured quantity, contrasting with the difficult measurement of I{sub pinch}. However, yield laws should be scaled to focus pinch current I{sub pinch} rather than the peak I{sub total}. This paper describes how I{sub pinch} may be computed from the I{sub total} trace by fitting a computed current trace to the measured current trace using the Lee model. The method is applied to an experiment in which both the I{sub total} trace and the plasma sheath current trace were measured. The result shows good agreement between the values of computed and measured I{sub pinch}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗