Read, Paul W

Publications and source records attributed to Read, Paul W.

Quantifying the Reproducibility of Heart Position During Treatment and Corresponding Delivered Heart Dose in Voluntary Deep Inhalation Breath Hold for Left Breast Cancer Patients Treated With External Beam Radiotherapy

Purpose: Voluntary deep inhalation breath hold (VDIBH) reduces heart dose during left breast irradiation. We present results of the first study performed to quantify reproducibility of breath hold using bony anatomy, heart position, and heart dose for VDIBH patients at treatment table. Methods and Materials: Data from 10 left breast cancer patients undergoing VDIBH whole-breast irradiation were analyzed. Two computed tomography (CT) scans, free breathing (FB) and VDIBH, were acquired to compare dose to critical structures. Pretreatment weekly kV orthogonal images and tangential ports were acquired. The displacement difference from spinal cord to sternum across the isocenter between coregistered planning Digitally Reconstructed Radiographs (DRRs) and kV imaging of bony thorax is a measure of breath hold reproducibility. The difference between bony coregistration and heart coregistration was the measured heart shift if the patient is aligned to bony anatomy. Results: Percentage of dose reductions from FB to VDIBH: mean heart dose (48%, SD 19%, p = 0.002), mean LAD dose (43%, SD 19%, p = 0.008), and maximum left anterior descending (LAD) dose (60%, SD 22%, p = 0.008). Average breath hold reproducibility using bony anatomy across the isocenter along the anteroposterior (AP) plane from planning to treatment is 1 (range, 0-3; SD, 1) mm. Average heart shifts with respect to bony anatomy between different breath holds are 2 {+-} 3 mm inferior, 1 {+-} 2 mm right, and 1 {+-} 3 mm posterior. Percentage dose changes from planning to delivery: mean heart dose (7%, SD 6%); mean LAD dose, ((9%, SD 7%)S, and maximum LAD dose, (11%, SD 11%) SD 11%, p = 0.008). Conclusion: We observed excellent three-dimensional bony registration between planning and pretreatment imaging. Reduced delivered dose to heart and LAD is maintained throughout VDIBH treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic MRI of Grid-Tagged Hyperpolarized Helium-3 for the Assessment of Lung Motion During Breathing

Purpose: To develop a dynamic magnetic resonance imaging (MRI) tagging technique using hyperpolarized helium-3 (HP He-3) to track lung motion. Methods and Materials: An accelerated non-Cartesian k-space trajectory was used to gain acquisition speed, at the cost of introducing image artifacts, providing a viable strategy for obtaining whole-lung coverage with adequate temporal resolution. Multiple-slice two-dimensional dynamic images of the lung were obtained in three healthy subjects after inhaling He-3 gas polarized to 35%-40%. Displacement, strain, and ventilation maps were computed from the observed motion of the grid peaks. Results: Both temporal and spatial variations of pulmonary mechanics were observed in normal subjects, including shear motion between different lobes of the same lung. Conclusion: These initial results suggest that dynamic imaging of grid-tagged hyperpolarized magnetization may potentially be a powerful tool for observing and quantifying pulmonary biomechanics on a regional basis and for assessing, validating, and improving lung deformable image registration algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reproducibility of Interfraction Lung Motion Probability Distribution Function Using Dynamic MRI: Statistical Analysis

Purpose: To investigate the statistical reproducibility of craniocaudal probability distribution function (PDF) of interfraction lung motion using dynamic magnetic resonance imaging. Methods and Materials: A total of 17 subjects, 9 healthy volunteers and 8 lung tumor patients, underwent two to three continuous 300-s magnetic resonance imaging scans in the sagittal plane, repeated 2 weeks apart. Three pulmonary vessels from different lung regions (upper, middle, and lower) in the healthy subjects and lung tumor patients were selected for tracking, and the displacement PDF reproducibility was evaluated as a function of scan time and frame rate. Results: For both healthy subjects and patients, the PDF reproducibility improved with increased scan time and converged to an equilibrium state during the 300-s scan. The PDF reproducibility at 300 s (mean, 0.86; range, 0.70-0.96) were significantly (p < 0.001) increased compared with those at 5 s (mean, 0.65; range, 0.25-0.79). PDF reproducibility showed less sensitivity to imaging frame rates that were >2 frames/s. Conclusion: A statistically significant improvement in PDF reproducibility was observed with a prolonged scan time among the 17 participants. The confirmation of PDF reproducibility over times much shorter than stereotactic body radiotherapy delivery duration is a vital part of the initial validation process of probability-based treatment planning for stereotactic body radiotherapy for lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semiconductor Nanoparticles as Energy Mediators for Photosensitizer-Enhanced Radiotherapy

Purpose: It has been proposed that quantum dots (QDs) can be used to excite conjugated photosensitizers and produce cytotoxic singlet oxygen. To study the potential of using such a conjugate synergistically with radiotherapy to enhance cell killing, we investigated the energy transfer from megavoltage (MV) X-rays to a photosensitizer using QDs as the mediator and quantitated the enhancement in cell killing. Methods and Materials: The photon emission efficiency of QDs on excitation by 6-MV X-rays was measured using dose rates of 100-600 cGy/min. A QD-Photofrin conjugate was synthesized by formation of an amide bond. The role of Foerster resonance energy transfer in the energy transferred to the Photofrin was determined by measuring the degree of quenching at different QD/Photofrin molar ratios. The enhancement of H460 human lung carcinoma cell killing by radiation in the presence of the conjugates was studied using a clonogenic survival assay. Results: The number of visible photons generated from QDs excited by 6-MV X-rays was linearly proportional to the radiation dose rate. The Foerster resonance energy transfer efficiency approached 100% as the number of Photofrin molecules conjugated to the QDs increased. The combination of the conjugate with radiation resulted in significantly lower H460 cell survival in clonogenic assays compared with radiation alone. Conclusion: The novel QD-Photofrin conjugate shows promise as a mediator for enhanced cell killing through a linear and highly efficient energy transfer from X-rays to Photofrin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Coplanar Partial Left Breast Irradiation Using Tomotherapy-Based Topotherapy

Purpose: To investigate the use of topotherapy for accelerated partial breast irradiation through field-design optimization and dosimetric comparison to linear accelerator-based three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT). Methods and Materials: Hypothetical 3-cm lumpectomy sites were contoured in each quadrant of a left breast by using dosimetric guidelines from the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 protocol. Coplanar intensity-modulated topotherapy treatment plans were optimized by using two-, three-, four-, five-, and seven-field arrangements for delivery by the tomotherapy unit with fixed gantry angles. Optimized noncoplanar five-field 3D-CRT and IMRT were compared with corresponding topotherapy plans. Results: On average, 99.5% {+-} 0.5% of the target received 100% of the prescribed dose for all topotherapy plans. Average equivalent uniform doses ranged from 1.20-2.06, 0.79-1.76, and 0.10-0.29 Gy for heart, ipsilateral lung, and contralateral lung, respectively. Average volume of normal breast exceeding 90% of the prescription and average area of skin exceeding 35 Gy were lowest for five-field plans. Average uniformity indexes for five-field plans using 3D-CRT, IMRT, and topotherapy were 1.047, 1.050, and 1.040, respectively. Dose-volume histograms and calculated equivalent uniform doses of all three techniques illustrate clinically equivalent doses to ipsilateral breast, lung, and heart. Conclusions: This dosimetric evaluation for a single patient shows that coplanar partial breast topotherapy provides good target coverage with exceptionally low dose to organs at risk. Use of more than five fields provided no additional dosimetric advantage. A comparison of five-field topotherapy to 3D-CRT and IMRT for accelerated partial breast irradiation illustrates equivalent target conformality and uniformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗