Search NASA⌕ Search

Engineering topics

Reda, Ibrahim

Publications and source records attributed to Reda, Ibrahim.

52 records · Page 3

The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint

Accurate solar radiation data sets are critical to reducing the expenses associated with mitigating performance risk for solar energy conversion systems, and they help utility planners and grid system operators understand the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of calibration methodologies and the resulting calibration responsivities provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these radiometers are calibrated indoors, and some are calibrated outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The reference radiometer calibrations are traceable to the World Radiometric Reference. These different methods of calibration demonstrated 1% to 2% differences in solar irradiance measurement. Analyzing these values will ultimately assist in determining the uncertainties of the radiometer data and will assist in developing consensus on a standard for calibration.

14 SOLAR ENERGY↗

Traceable Pyrgeometer Calibrations

This poster presents the development, implementation, and operation of the Broadband Outdoor Radiometer Calibrations (BORCAL) Longwave (LW) system at the Southern Great Plains Radiometric Calibration Facility for the calibration of pyrgeometers that provide traceability to the World Infrared Standard Group.

14 SOLAR ENERGY↗

Traceable Pyrgeometer Calibrations

This presentation provides a high-level overview of the progress on the Broadband Outdoor Radiometer Calibrations for all shortwave and longwave radiometers that are deployed by the Atmospheric Radiation Measurement program.

14 SOLAR ENERGY↗

Measuring Broadband IR Irradiance in the Direct Solar Beam (Presentation)

Solar and atmospheric science radiometers, e.g. pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference, which is maintained by Absolute Cavity Radiometers (ACRs). The ACR is an open cavity with no window, developed to measure extended broadband direct solar irradiance beyond the ultraviolet and infrared bands below and above 0.2 um and 50um, respectively. On the other hand, pyranometers and pyrheliometers are developed to measure broadband shortwave irradiance from approximately 0.3 um to 3 um, while the present photovoltaic cells are limited to approximately 0.3 um to 1 um. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in thesolar and atmospheric science literature. Pyrgeometers are also used for solar and atmospheric science applications and are calibrated with traceability to consensus reference, yet are calibrated during nighttime only, because no consensus reference has yet been established for the daytime longwave irradiance. This poster shows a method to measure the broadband IR irradiance in the direct solarbeam from 3 um to 50 um, as a first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The irradiance was measured from sunrise to sunset for 5 days when the sun disk was cloudless; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 for solar zenithangle from 80 degrees to 16 degrees respectively; estimated uncertainty is 1.5 Wm-2.

14 SOLAR ENERGY↗

Uncertainty Estimates for SIRS, SKYRAD, & GNDRAD Data and Reprocessing the Pyrgeometer Data (Presentation)

The National Renewable Energy Laboratory (NREL) and the Atmospheric Radiation Measurement (ARM) Climate Research Facility work together in providing data from strategically located in situ measurement observatories around the world. Both work together in improving and developing new technologies that assist in acquiring high quality radiometric data. In this presentation we summarize the uncertainty estimates of the ARM data collected at the ARM Solar Infrared Radiation Station (SIRS), Sky Radiometers on Stand for Downwelling Radiation (SKYRAD), and Ground Radiometers on Stand for Upwelling Radiation (GNDRAD), which ultimately improve the existing radiometric data. Three studies are also included to show the difference between calibrating pyrgeometers (e.g., Eppley PIR) using the manufacturer blackbody versus the interim World Infrared Standard Group (WISG), a pyrgeometer aging study, and the sampling rate effect of correcting historical data.

14 SOLAR ENERGY↗

NREL Pyrheliometer Comparison: September 16 to 27, 2013 (NPC-2013)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for the development and deployment of solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations traceable to an international standard is the first step in producing research-quality solar irradiance measurements. As with all measurement systems, absolute cavity radiometers and other types of pyrheliometers are subject to performance changes over time. NREL has developed and maintained a group of absolute cavity radiometers with direct calibration traceability to the World Radiometric Reference (WRR). These reference instruments are used by NREL to calibrate pyrheliometers and pyranometers using the ISO 17025 accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). NPCs are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all pyrheliometer owners/operators, e.g. NREL, NASA, NIST, NOAA, USA industry and academia, USA-DOE and other national laboratories, and national and international organizations. Each NPC provides an opportunity to determine the unique World Radiometric Reference (WRR) transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the International System of Units through WRR.

14 SOLAR ENERGY↗

Absolute cavity pyrgeometer

Implementations of the present disclosure involve an apparatus and method to measure the long-wave irradiance of the atmosphere or long-wave source. The apparatus may involve a thermopile, a concentrator and temperature controller. The incoming long-wave irradiance may be reflected from the concentrator to a thermopile receiver located at the bottom of the concentrator to receive the reflected long-wave irradiance. In addition, the thermopile may be thermally connected to a temperature controller to control the device temperature. Through use of the apparatus, the long-wave irradiance of the atmosphere may be calculated from several measurements provided by the apparatus. In addition, the apparatus may provide an international standard of pyrgeometers' calibration that is traceable back to the International System of Units (SI) rather than to a blackbody atmospheric simulator.

47 OTHER INSTRUMENTATION↗

SAMPA (Solar and Moon Position Algorithm)

SAMPA calculates the location of the Sun and Moon in the sky for the purpose of solar eclipse monitoring and for estimating the influence on solar irradiance. Valid from the year -2000 to 6000, with an uncertainty of +/- 0.0003 degrees for the Sun position and +/- 0.003 degrees for the Moon position.

Reda, Ibrahim↗

Introducing an Absolute Cavity Pyrgeometer for Improving the Atmospheric Longwave Irradiance Measurement (Presentation)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer(ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined bylowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the WorldRadiation Center with traceability to the WISG. A total of 408 readings was collected over three different clear nights. The calculated irradiance measured by the ACP was 1.5 W/m2 lower than that measured by the two pyrgeometers that are traceable to WISG. Further development and characterization of the ACP might contribute to the effort of improving the uncertainty and traceability of WISG toSI.

47 OTHER INSTRUMENTATION↗

Solar Radiation Research Laboratory (Poster)

SunShot Initiative awardee posters describing the different technologies within the four subprograms of the DOE Solar Program (Photovoltaics, Concentrating Solar Power, Soft Costs, and Systems Integration).

14 SOLAR ENERGY↗

Introducing an Absolute Cavity Pyrgeometer (ACP) for Improving the Atmospheric Longwave Irradiance Measurement (Poster)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer(ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined bylowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the WorldRadiation Center with traceability to the WISG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗