Search NASA⌕ Search

Engineering topics

Reed, Ted R

Publications and source records attributed to Reed, Ted R.

Mobile Hot Cell Digital Twin: End-of-life Management of Disused High Activity Radioactive Sources

Sealed radioactive sources are used in various settings such as nuclear facilities, universities, hospitals, and industry. When these sources reach the end of their lifespan, they become waste and are recaptured and stored long-term. A digital twin can be used in the design of a solution for recapturing spent sources, offering benefits in deployment time, operator safety, and cost reduction. We propose a digital twin framework for managing the end-of-life process of disused high activity radioactive sources and have created a prototype implementation to demonstrate its feasibility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mobile Hot Cell Digital Twin: End-of-life Management of Disused High Activity Radioactive Sources – 23598

Sealed radioactive sources are utilized for a wide range of applications across nuclear facilities, universities, hospitals, and industry. When these sources reach the end of serviceable life, they become waste. As waste, this radioactive material then goes through a process of recapture and then transfer to long term storage. With the advancement of technology in conjunction with better accessibility of technology, industries are exploring the use of digital automation to enhance productivity, efficiency, and safety while minimizing operation and maintenance costs, health and environmental risks, and uncertainty in the project life cycles. One area for exploration is the use of a digital twin to help design a robust, versatile, and safe solution for recapturing spent sources. We believe this avenue can also provide further advantages in the operations aspect of end-of-life management of spent radioactive sources by reducing the deployment time, increasing operator safety, and reducing operation & maintenance cost. We present a novel digital twin framework for end-of-life management of disused high activity radioactive sources. We have designed and developed a framework that houses a digital twin for visualizing and monitoring the recapture process to inform the engineering and design of a new Mobile Hot Cell. Furthermore, we demonstrate the feasibility of the proposed framework by providing a prototypical implementation, supporting the Mobile Hot Cell and human-machine interface's virtual replication.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mobile Hot Cell Digital Twin using Immersive Virtual Environment

Sealed radioactive sources are utilized for a wide range of applications across nuclear facilities, universities, hospitals, and industry. When these sources reach the end of their serviceable life, they become waste. This radioactive waste then goes through a process of recapture and then transfer to long term storage. With the advancement of technology in conjunction with better accessibility of technology, industries are exploring the use of digital automation to enhance productivity, efficiency, and safety while minimizing operation and maintenance costs, health and environmental risks, and uncertainty in the project life cycles. One area for exploration and the use of Digital Twin for providing a robust, versatile, and safe solution for recapturing spent sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

ECAR-1943 AGC-1 INDIVIDUAL SPECIMEN FLUENCE, TEMPERATURE, AND LOAD CALCULATION AND TABULATION

This ECAR calculates the fluence and temperature of the AGC-1 specimens as they change elevation through the course of the experiment. The specimen elevation varies as the specimen stack shrinks due to irradiation and load induced creep. The compressed specimen stacks (S-1 thru S-6) have a graphite pushrod that applies a gas cylinder load. The top of the pushrod position is measured and recorded in the NGNP Data Management and Analysis System (NDMAS). The bottom of each of these compressed stacks is supported by the lower specimen holder which also shrinks as a result of irradiation and load. The specimen holder post-irradiation length was recorded during post-irradiation examination (PIE). Assuming the specimen holder shrinkage is linear with respect to the fluence received, the position of the top of the specimen holder can be calculated with respect to reactor integrated power. Assuming that individual specimen shrinkage is proportional to the fluence received, and that the shrinkage behavior is similar in all the specimens, the individual specimen position can be calculated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AGC-2 Specimen Position Adjustment

This engineering calculations and analysis report (ECAR) calculates the Advanced Graphite Creep (AGC)-2 specimen position adjustments that result from (1) as-built dimension corrections of the Advanced Test Reactor (ATR) reactor, experiment, and specimens, (2) thermal growth of the capsule wall and graphite components, and (3) variable specimen elevations as the specimen stacks shrink due to radiation -induced shrinkage and axial load- induced creep. The specimen elevations listed in the experiment assembly documents do not accurately represent the actual specimen positions in relation to the reactor core mid-plane. Prior experiment insertion difficulties have shown that the distance from the reactor top head closure plate to the core is greater than the nominal elevations shown on the ATR facility drawings. Drawing 600001 lists the measured difference between the closure plate and the gearbox support beam as 0.313 in.ches greater than the facility drawings. Thus, the height of the specimens in relation to the core mid-plane is 0.313 in.ches higher than the nominal dimensions. AlsoIn addition, the overall dimension of the experiment is 0.084 in. shorter than the nominal drawing dimension on Drawing 601266 [1]. As a further adjustment, the average weld shrinkage of the three capsule welds is 0.035 each, which affects the as-built position of the lower isolation weld plate (i.e., Part #601266-9) onto which all graphite components are stacked. In addition to the as-built adjustments mentioned above, the specimens also are subject to a stack up error, which is due to their the thickness difference from nominal. This effect is most apparent in the center S-7 stack which that has a large number of specimens (i.e., 170 specimens). Per post-irradiation examination (PIE) measurements, the average S-7 specimen is about 0.0008 in. smaller than nominal. Even though this difference is small, when multiplied by the number specimens, the top specimen experiences an elevation reduction of 0.14 inches. Although dimensional changes were less pronounced in S-1 through S-6, specimen elevations were adjusted based on pre-irradiation length measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗