Energy Cost Savings of Systems-Based Building Retrofits: A Study of Three Integrated Lighting Systems in Comparison with Component Based Retrofits

Most building retrofit projects are still component-based in that they typically address only one piece or type of equipment at a time. Systems-based retrofits that seek to address multiple components in an integrated manner have the potential to provide significantly greater energy savings. Lawrence Berkeley National Laboratory (LBNL) partnered with several utilities to develop and evaluate three different integrated retrofit packages involving lighting systems: automated shading with daylight dimming controls, workstation-specific lighting with daylight controls, and task/ambient lighting with plug load occupancy controls. Specifically, our analysis sought to quantify the marginal benefits of these systems (energy savings as well as lighting performance and visual comfort) relative to component based approaches. The analysis was based on a combination of measured performance data from LBNL’s FLEXLAB® test facility and energy simulations. All three systems were compared to a simple fluorescent-to-LED retrofit, which represents the component-based approach. While the simple LED upgrade provides significant lighting energy savings of 63%, the systems yielded energy savings of 81-93%, which equates to additional savings of 49-82% over the simple LED upgrade. All systems tested provided satisfactory visual comfort as well, indicating good potential for market acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the benefits of a building retrofit using an integrated system approach: A case study

Building retrofits provide a large opportunity to significantly reduce energy consumption in the buildings sector. Traditional building retrofits focus on equipment upgrades, often at the end of equipment life or failure, and result in replacement with marginally improved similar technology and limited energy savings. The Integrated System (IS) retrofit approach enables much greater energy savings by leveraging interactive effects between end use systems, enabling downsized or lower energy technologies. This work presents a case study in Hawaii quantifying the benefits of an IS retrofit approach compared to two traditional retrofit approaches: a Standard Practice of upgrading equipment to meet minimum code requirements, and an Improved Practice of upgrading equipment to a higher efficiency. The IS approach showed an energy savings of 84% over existing building energy use, much higher than the traditional approaches of 13% and 33%. The IS retrofit also demonstrated the greatest energy cost savings potential. While the degree of savings realized from the IS approach will vary by building and climate, these findings indicate that savings on the order of 50% and greater are not possible without an IS approach. It is therefore recommended that the IS approach be universally adopted to achieve deep energy savings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

California Publicly-Owned Utilities (POUs) – LBNL ‘Beyond Widgets’ Project. Task: ambient lighting and occupancy-based plug load control. System Program Manual

This program manual contains detailed technical information for implementing an incentive program for task-ambient lighting and occupancy-based plug load control. This manual was developed by Lawrence Berkeley National Laboratory, in collaboration with the California Publicly-Owned Utilities (CA POUs) as a partner in the ‘Beyond Widgets’ program funded by the U.S. Department of Energy Building Technologies Office. The primary audience for this manual is the program staff of the various CA POUs. It may also be used by other utility incentive programs to help develop similar programs. It is anticipated that the content of this manual be utilized by the CA POU staff for developing related documents such as the Technical Resource Manual and other filings pertaining to the rollout of an energy systems-based rebate incentive program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transforming BIM to BEM: Generation of Building Geometry for the NASA Ames Sustainability Base BIM

Typical processes of whole Building Energy simulation Model (BEM) generation are subjective, labor intensive, time intensive and error prone. Essentially, these typical processes reproduce already existing data, i.e. building models already created by the architect. Accordingly, Lawrence Berkeley National Laboratory (LBNL) developed a semi-automated process that enables reproducible conversions of Building Information Model (BIM) representations of building geometry into a format required by building energy modeling (BEM) tools. This is a generic process that may be applied to all building energy modeling tools but to date has only been used for EnergyPlus. This report describes and demonstrates each stage in the semi-automated process for building geometry using the recently constructed NASA Ames Sustainability Base throughout. This example uses ArchiCAD (Graphisoft, 2012) as the originating CAD tool and EnergyPlus as the concluding whole building energy simulation tool. It is important to note that the process is also applicable for professionals that use other CAD tools such as Revit (“Revit Architecture,” 2012) and DProfiler (Beck Technology, 2012) and can be extended to provide geometry definitions for BEM tools other than EnergyPlus. Geometry Simplification Tool (GST) was used during the NASA Ames project and was the enabling software that facilitated semi-automated data transformations. GST has now been superseded by Space Boundary Tool (SBT-1) and will be referred to as SBT-1 throughout this report. The benefits of this semi-automated process are fourfold: 1) reduce the amount of time and cost required to develop a whole building energy simulation model, 2) enable rapid generation of design alternatives, 3) improve the accuracy of BEMs and 4) result in significantly better performing buildings with significantly lower energy consumption than those created using the traditional design process, especially if the simulation model was used as a predictive benchmark during operation. Developing BIM based criteria to support the semi-automated process should result in significant reliable improvements and time savings in the development of BEMs. In order to define successful BIMS, CAD export of IFC based BIMs for BEM must adhere to a standard Model View Definition (MVD) for simulation as provided by the concept design BIM MVD (buildingSMART, 2011). In order to ensure wide scale adoption, companies would also need to develop their own material libraries to support automated activities and undertake a pilot project to improve understanding of modeling conventions and design tool features and limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗